Flow Control CLEANING / REPLACEMENT Procedure

 

 

 
Step #1 

 
  Please remove the Brew Express from the wall by removal of 4 outside set screws, and  
  pull away by holding the sides of the unit. Upon removal, press a grey button on the  
  water line (quick-connection) to disconnect the water line.  
 

      

 

 

      

 

Содержание Brew Express

Страница 1: ...PLACEMENT Procedure Step 1 Please remove the Brew Express from the wall by removal of 4 outside set screws and pull away by holding the sides of the unit Upon removal press a grey button on the water line quick connection to disconnect the water line ...

Страница 2: ...45B7DF64 103B 08A7B4 doc Step 2 Place Brew Express face down on a towel to protect front face ...

Страница 3: ...lve connection nut with 18 mm or equivalent wrench Step 4 Carefully pull away slightly and Rotate water line using pliers Caution Gasket O ring seal may fall into unit Remove watch so it does not fall off Caution Do Not Bend copper line JUST ROTATE ...

Страница 4: ...45B7DF64 103B 08A7B4 doc Step 5 Remove flow control with 18 mm or equivalent wrench ...

Страница 5: ...B4 doc Step 6 To Clean for low volume Flow Problem Rinse under strong stream of water to clean or and use small paper clip wire to push through center hole to clear Dry with towel For Replacement of Flow Control Go to 7 ...

Страница 6: ...45B7DF64 103B 08A7B4 doc Step 7 Place Cleaned or Replacement flow control back into valve Seal O Ring on flow control should be upward direction only ...

Страница 7: ...4 doc Tighten with wrench snug to valve Step 8 Re Align copper line with flow control by rotating Ensure small o ring did not fall off Tighten nut snug to secure copper line to flow control Do not over tighten nut O ring ...

Страница 8: ...pray head recommended and run two pots of water without spray head to clear any debris that maybe in the system Re install spray head Complete Cleaning or Replacement of flow control should only take about 10 minutes to perform Should this procedure not work please feel free to call or email Lance Larkin LLC for further instructions Phone 866 268 5953 Email info lancelarkin com ...

Страница 9: ...45B7DF64 103B 08A7B4 doc ...