Lamptron CW611 Скачать руководство пользователя страница 1

     and      represent the output of that channel,      value,      units, 

You can choose speed (RPM), voltage (Vol), or flow units (LPH GPM), 

the default is speed (RPM).

Tip: Only in the channel used by the electronic flowmeter can you choose 

the flow unit, fan and pump modes can only use speed (RPM) or voltage

(Vol) units.

 Connect the power supply “P”, the controller goes into normal operation,

and the screen will display “                        ” logo; press Key     or Key    , 

Or rotate     ; enter the main interface explained below:

                              Show channel 1~6 icon,       position for the selected 

channel,You can use the knob      clockwise or counter-clockwise rotation 

to rotate through the channels. Icons                         . Each channel can 

choose one in three operational modes. The default is fan mode when 

you first start your CW611:

Lamptron CW611 instruction manual

SPECIFICATIONS:

   Thank you for choosing the LAMPTRON CW611 

controller, this controller is designed & optimized for 

both air-cooled and water-cooled applications. 

For computer use only.  

Large screen, narrow border design, clear and pleasing white on 

black, high-brightness backlight.  

Use of a knob and a secondary button will allow you to be able to 

use all of the functions easily.  

Each channel can be used in three optional modes of fan, pump and 

flow meter. Every channel is identified with an intuitive icon for each 

mode.

Each channel can be individually set to manual mode (M) or 

automatic mode (A). Set the target temperature of the channel in 

automatic mode and you can specify the lowest output value and the

highest output value per channel. If the actual temperature does not 

reach the target temperature, the output remains in the minimum set 

value, when the actual temperature exceeds the target temperature, 

the output begins to increase. Automatic control supports fans 

equipped with or without tachometers. 

Each of the 6 channels has a maximum output of 36 watts, which you 

can easily cycle using the knob.

When a channel is placed in fan or water pump mode, you can set 

the channel to show voltage or speed units.

Backlight brightness options of 20%, 50%, 80%, 100%, and OFF, so 

you can choose what suits you best. 

Each individual channel can turn on or off the alarm based on Celsius 

or Fahrenheit.  

Commonly used features and advanced functions are separated, 

press the knob for a short period to enter the frequently used 

functions of the current channel settings, or press it for a longer 

period to enter the advanced features of the current channel. 

Press the auxiliary key to navigate through the options while in that 

mode, one finished, press the knob for a shot period to return to the 

main interface.

OPERATION:

Dimension 

148.5mm * 42.5mm * 63mm

 

LCD Dimension

 

118mm * 31mm(wide screen)

 

Power Output

 

Up to 36 watts per channel

Control Channel

 

6 Channels

 

Color Available

 

Black Anodized/Silver

 

DC Input

+ 12V(Standard “D” Connector

 

DC Output

0V - 12V DC

Connectors  

6pcs 3pin connectors

INSTALLATION:

   The CW611 is designed to fit in a 5.25” bay, please use the included 

screws to install it within your pc case. (Phillips screwdriver required 

and not included) 

Installation location: 

     Press and hold the knob to enter the settings of the current channel. 

To enter the commonly used settings, press the knob for a short period. 

To enter the more advanced settings, press for a longer period. 

Rotate the knob to change the parameters accordingly. 

Press the knob for a short period to exit to the main screen.
     Auxiliary keys used to confirm setting changes after selecting them 

within the menu (access explained in the previous point). In addition, in 

the main interface, press the auxiliary button       can switch the backlight 

brightness, backlight will be 100% > 80% > 50% > 20% > turn off the 

backlight > 20% > 50% > 80% > 100% of the sequence cycle. 

CONNECTIONS:

Instructions:

1.  P: Standard Molex. Connect to your power supply.

Tip: Be sure to use at least 18AWG wiring specifications.

2.  P1 ~ P6: Channels 1 to 6 output interface (compatible fan, water 

pump, electronic flow meter), the six interfaces are standard with 

KF2510 3pin interfaces.

Tip: You can also use a KF2510 4pin connector.

3.  TEMP1 ~ TEMP6: are respectively connected to the P1~P6 

secondary connectors corresponding to the sensors.

Tip: Automatic control of each output channel is carried out according 

to the temperature reported by the temp sensors.

 

 

1

1

2

12

2

3 4 5 6 7 8

    Alarm icon, The default is off (which will show      , when turned on, 

it´ll show     . Each channel can be individually turned on or off (in terms 

of the Alarm).

 

 

 

 

 

CW611

1

2

Fan

Water Pump

Electronic Flow Meter

3

4

8

5

7

6

9

10

11

12

13 14 15

2

1

CW611

1

2

3

1

3 4 5 6 7

9

Shows current operational mode. 

10

10

11

11

13
14

15

The temperature values of the currently selected channel.

Temperature unit, the default is Celsius 

 but can be changed to 

Fahrenheit 

 . Each channel can be individually defined.

Current backlight level. Instructions on how to change this are written 

earlier in this manual.

F

Отзывы: