Figure 33
BLOWER ASSEMBLY
BOX 422 • TOWER, MN 55790 • USA • Tel (218) 753-2330 • www.lamppakuuma.com
24
Install the removable heat exchanger baffles (A & B)
via the clean out cover opening (Figure 34). They are
quickly removed for cleaning purposes. The baffles
allow for greater heat extraction and higher overall
efficiency. Center each baffle from one side to the
other.
CAUTION: If you have a poor draft set-up, such as
connecting to an outside chimney with horizontal
piping, 90° elbows, or a short chimney, do not in-
stall the heat exchanger baffles; you could get a draft
reversal. Smoke backing up or the smell of smoke
would indicate a poor draft. If questionable, have
your draft checked by a certified installer.
REMOVABLE HEAT EXCHANGER
BAFFLE A
REMOVABLE HEAT EXCHANGER
BAFFLE B
CERAMIC INSULATION
OPEN END FACES FRONT
CLEAN OUT OPENING
A
TOP
B
Figure 27
FIRE CHAMBER
VF-100
(SIDE VIEW)
CROSS SECTION
2’ X 2’ OUTLET
HE
AT E
XC
HA
NG
ER
TU
BES
ACCESS
CLEAN
OUT
COVER
HEAT
EXCHANGER
BAFFLES
A
B
6”
EXHAUST
INNER 8”
THROAT
D
O
O
R
B
A
C
K
FRONT
LIFT OFF
HOOD
AIR JACKET HOOD
AIR
JACKET
HOOD
CHECK YOUR FIREWOOD
WITH THE MOISTURE
METER PROVIDED —
FOLLOW DIRECTIONS.