DC1500 

IRON 

 

Iron Colorimeter Kit

Code  3248

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание DC1500 IRON

Страница 1: ...DC1500 IRON Iron Colorimeter Kit Code 3248 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...ting Power Save 16 Setting Backlight Time 17 Selecting A Language 18 Looping Menus 19 Computer Connection Output 20 Computer Connection 20 Battery Battery AC Operation 20 Battery Replacement 21 Mainte...

Страница 3: ...cautions 27 Limits of Liability 27 Speci cations 28 CE 29 IP67 29 Warranty 29 Register Your Meter 29 Trouble Shooting Guide Error Messages 30 Calibration 30 Stray Light 30 Troubleshooting Guide 31 www...

Страница 4: ...Collecting Bottle 0688 1 1500 Colorimeter for Iron 27926 IR 1 USB Wall Adapter 1721 1 USB Cable 1720 1 DC1500 IR Iron Colorimeter Manual 3248 MN 1 DC1500 IR Iron Colorimeter Quick Start Guide 3248 QG...

Страница 5: ...orm of iron which is present and the end use of the treated water APPLICATION Drinking surface and saline waters domestic and industrial wastes RANGE 0 00 to 5 00 ppm Iron METHOD Ferric iron is reduce...

Страница 6: ...Press ENTER to select Testing Menu All Tests 056 Iron Phenanthro 12 00 00 001 500 4 Scroll to and select 056 Iron Phenanthro from menu 056 Iron Phenanthro Scan Blank Scan Sample 12 00 00 001 500 5 Ri...

Страница 7: ...color development Wipe tube dry 05 00 9 Insert tube into chamber Close lid Select Scan Sample Record result as ppm Ferrous Iron 056 Iron Phenanthro 0 99 ppm Scan BLank Scan Sample 12 00 00 001 500 10...

Страница 8: ...s performed To use the previous blank reading instead of scanning a new one scroll to Scan Sample and proceed For the most accurate results the meter should be blanked before each test and the same tu...

Страница 9: ...The LaMotte logo screen will appear for about 3 seconds and the Main Menu will appear Main Menu Testing Menu Editing Menu 12 00 00 001 500 2 Press ENTER to select Testing Menu All Tests 056 Iron Phen...

Страница 10: ...Add 6 drops of Acid Phenanthroline Indicator 2776 7 Cap and invert 4 times to mix 05 00 8 Use the 0 1 g spoon 0699 to add one measure of Iron Reducing Reagent 2777 9 Cap and invert 15 times to mix Cal...

Страница 11: ...elect Calibrate A reverse font light background with dark characters will appear to indicate that the reading can be adjusted 056 Iron Phenanthro 0 99 ppm Edit ENTER Save ENTER Default 12 00 00 001 50...

Страница 12: ...nd ENTER at any time to return to the default value The calibration has now been standardized and can be used for testing Scroll to Scan Blank and begin testing 056 Iron Phenanthro 1 00 ppm T Abs Cali...

Страница 13: ...year is displayed Press or to scroll to the appropriate character Press ENTER to select the character The month day hour format hour minute second AM PM will be dislpayed Repeat for each Set Time Yea...

Страница 14: ...diting Menu Set Clock Logging Factory Setup Set Power Save 12 00 00 001 500 2 Press ENTER to select Logging Logging Display Test Log Logging Enabled Logging Disabled Erase Log 12 00 00 001 500 3 Press...

Страница 15: ...er Save Editing Menu Set Clock Logging Factory Setup Set Power Save 12 00 00 001 500 2 Press ENTER to select Set Power Save Set Power Save Disable 5 Minutes 15 Minutes 30 Minutes 12 00 00 001 500 3 Pr...

Страница 16: ...attery will have to be charged if the USB Wall Adapter is not being used 1 From the Editing Menu press or to scroll to Backlight Time Editing Menu Logging Factory Setup Set Power Save Set Backlight Ti...

Страница 17: ...anguage Select Language English Spanish French Portugese 12 00 00 001 500 4 Press ENTER The screen will display Storing for about 1 second and the meter will return to the Editing Menu Editing Menu Se...

Страница 18: ...ow demonstrate a looping menu AND SO ON AND SO ON AND SO ON THIRD TO LAST LAST CHOICE LAST CHOICE SECOND TO LAST AND SO ON AND SO ON LAST CHOICE TESTING MENU TESTING MENU TESTING MENU FIRST CHOICE SEC...

Страница 19: ...ttery icon will show four bars and stop ashing when it is fully charged The charging circuit will automatically switch to a oat charge when the battery is fully charged The charger may remain connecte...

Страница 20: ...the meter To clean the light chamber and optics area point a can of compressed air into the light chamber and blow the pressurized air into the light chamber Use a cotton swab dampened with Windex wi...

Страница 21: ...he user to select options from the menu driven software to directly read test results or to review stored results of previous tests in the data logger The menus can be displayed in seven di erent lang...

Страница 22: ...isplays the title of the current menu The footer line displays the time and the date the data logger status and the battery status The menu selection window is in the middle of the display between the...

Страница 23: ...tte logo is displayed The top two lines of the display are used to display information in a large easy to read format The menus work in the same way as previously described but two lines of the menu a...

Страница 24: ...n an inverted position to prevent dust from entering the tubes Dry tubes should be stored with the caps on to prevent contamination After a tube has been lled and capped it should be held by the cap a...

Страница 25: ...e result falls within the range of the calibration Multiply the test result by the dilution factor For example if 10 mL of the sample water is diluted with three 10 mL volumes of deionized water the d...

Страница 26: ...ur digit LaMotte code number found on the container label or at the top of the SDS or in the contents list of the procedure LaMotte reagents are registered with a computerized poison control informati...

Страница 27: ...lection Languages English Spanish French Portuguese Italian Chinese Japanese Temperature Operation 0 50 C Storage 40 60 C Operation Humidity Range 0 90 RH non condensing USB Port Mini B Power Requirem...

Страница 28: ...00 00 001 500 CALIBRATION As with all pre calibrated meters it is highly recommended even if not required by regulations that the user periodically verify the performance of the meter by running stand...

Страница 29: ...Shut Down Battery is too low to operate the unit Charge battery or use USB wall computer adapter Overrange Sample is outside of acceptable range Dilute sample and test again Unusually large negative...

Страница 30: ...3248 MN 3 13 17 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Отзывы: