LAMINOX KING HEAT 6 Скачать руководство пользователя страница 1

 

-  1- 

                                                                   

 

DC INVERTER MULTIFUNCTIONAL   

AIR TO WATER HEAT PUMP 

 

User Manual   

 

 

 

Model: KING HEAT 6 / 9 / 12 / 18 

 

 

Содержание KING HEAT 6

Страница 1: ...1 DC INVERTER MULTIFUNCTIONAL AIR TO WATER HEAT PUMP User Manual Model KING HEAT 6 9 12 18...

Страница 2: ...Diagram 18 4 4 2 Wiring Diagram 19 4 4 4 Installation Drawing 21 4 4 5 DHW anti freeze 22 4 4 6 AC anti freeze 23 4 5 Commissioning 23 4 5 1 Preparations 23 4 5 2 Inspection before Start up 24 4 5 3...

Страница 3: ...alified personnel only Incorrect installation of this heat pump could result in damage to people animals or property and the manufacturer will not be held liable in such cases 2 Safety warnings 2 1 Us...

Страница 4: ...gers Touching a switch with wet fingers may cause electric shock Before accessing the electrical components of the heat pump disconnect the main power supply completely Disconnect all electricity sour...

Страница 5: ...o this it is of paramount importance that this type of machine is protected against such frost The freezing of the water inside the heat pump causes the heat pump to breakdown with the subsequent inte...

Страница 6: ...r water heat pump specially designed for the colder climate There is no need for bore holes and usually the system can be installed within 1 day The unit can both heat hot water effectively at high ou...

Страница 7: ...the heat pump with side outlet wind consider the local wind direction and choose a reasonable installation direction to avoid the wind direction being opposite Current regulations require the heating...

Страница 8: ...tallation on the ground is the most advisable Straighten the heat pump well to ensure that the condensate water cannot exit through any paths other than the intended drain hole Fasten it firmly using...

Страница 9: ...at pump is not disruptive to neighbors sound level air currents generated low temperature of the air blown with risk of freezing plants in the path etc Choose a location that preferably has sunlight a...

Страница 10: ...the appliance away from heat sources and flammable products In areas where abundant and copious snowfalls occur special care must be taken to protect the heat pump from possible obstructions due to ac...

Страница 11: ...in a region where the temperature can be below 0 C for a long period of time 4 1 5 Accessories supplied The following accessories are supplied in the interior of the heat pump Before proceeding with...

Страница 12: ...essure sensors are all controlled The number of starts and the operating time after this power on can also be read The controller is set during installation and can be used during a service Under norm...

Страница 13: ...13 A 6 9 12 18 Space Heating Cooling DHW B 6 9 12 18 Space Heating Cooling Mode Only C 2x6 9 12 18 Installation Space Heating Cooling DHW...

Страница 14: ...14 D 3X6 9 12 18 Installation Space Heating Cooling DHW...

Страница 15: ...15 Solar Application 1 Solar Application 2...

Страница 16: ...n the return branch of the machine to avoid the entry of dirty water into the heat exchanger condenser The type of filter installed must be adapted to the particular characteristics of each installati...

Страница 17: ...a risk of damage due to freezing During the installation Anti freeze Ethylene Glycol is strongly recommended If the air temp is ever lower than 0 C it must use enough glycol 4 4 Electrical Connection...

Страница 18: ...18 4 4 1 System Diagram A P90 1 P65 1 B P90 0 P65 0...

Страница 19: ...19 4 4 2 Wiring Diagram KING HEAT 6 9 12...

Страница 20: ...20 KING HEAT 18...

Страница 21: ...he main power supply The heat pump is prepared for connection to 230V 50Hz in the terminals indicated in the figure see wiring Diagram Inside the machine open the front door and access to the electron...

Страница 22: ...al heater For the correct selection of the type and dimensions of machine s main supply cable it has take in account the electrical consumption of the optional accessories connected on the heat pump a...

Страница 23: ...ill be displayed 4 5 Commissioning 4 5 1 Preparations 1 Compressor Heater As mentioned above if the temperature is lower than 10 C the compressor heater will heat the compressor for 3 10 minutes befor...

Страница 24: ...rts After another 5 seconds compressor starts d Air is initially released from the hot water and venting may be necessary If bubbling sounds can be heard from the heat pump the circulation pump or rad...

Страница 25: ...C09 P35 2 If any of the above conditions are met the electric heater E1 will be turned off Note In DHW mode the electric heater E1 is turned on at the beginning of defrosting and the electric heater E...

Страница 26: ...e second heat source will be turned off f Motorized 3 way Valve G1 In DHW mode the motorized 3 way valve is power on In any other mode it is power off 5 2 Operating Mode Principle 1 Space Cooling Mode...

Страница 27: ...efinition and action Note For the icon Ts only when heat pump is with room temperature sensor then it is workable Room temperature sensor is optional 5 3 2 1 Turn on off Press ON OFF button for 3 seco...

Страница 28: ...only 2 Heating only 3 DHW only 4 Cooling DHW 5 Heating DHW When selected cooling or heating plus DHW DHW will be priority When selected DHW mode only DHW operation no cooling and heating Healthy ster...

Страница 29: ...ive value means move down 10 C 10 C C Auto heat curve highest temp is decided by parameter P08 from 30 50 default 45 When the parameter is 45 the AU highest target temp is 45 C 5 3 2 5 Timing Click ti...

Страница 30: ...al days 1 99 days 7 7 7 7 P11 Sterilisation start time 0 23 time 23 23 23 23 P12 Sterilisation running time 5 99min 10 10 10 10 P13 Sterilisation temperature 50 75 70 70 70 70 P14 Sterilisation mode s...

Страница 31: ...43 43 43 43 P52 High pressure value to cancel compressor frequency limit 2 0 4 5MPa display value multiply 0 1 39 39 39 39 P53 Protection pressure High 2 5 5 0MPa display value multiply 0 1 45 45 45 4...

Страница 32: ...n pump 1 DHW circulation pump 0 0 0 0 P89 Suction superheat percentage coefficient 0 20 5 5 5 5 P90 Suction superheat differential coefficient 0 20 1 1 1 1 P91 Defrost ambient temperature and coil tem...

Страница 33: ...performance data and working status Refrigerant circuit Hydraulic circuit 5 3 2 8 System protection and error list checking Click Error list button in the main menu or button in hydraulic circuit or r...

Страница 34: ...rror E16 Communication error Main board and controller communication error E17 Discharge temp too high protection 1 refrigerant volume too little 2 throttling part error E18 19 Reserved E20 IPM abnorm...

Страница 35: ...connected with heat pump RS485 1 by 4 wires must in order max 100m 5 6 Definition of abbreviation displayed in the controller Displayed in main interface Tr Room temperature Ts Room temperature setti...

Страница 36: ...pport 6 Expansion vessel 7 Electrical box support 8 Compressor 9 Heat exchanger 10 Water pump 11 Base plate 12 Right side service plate 13 Heat exchanger support 14 Front service plate 15 Front panel...

Страница 37: ...box support 8 Compressor 9 Gas liquid separator 10 Water pump 11 Heat exchanger 12 Base plate 13 Right side service plate 14 Heat exchanger support 15 Front service plate 16 Front panel 17 Fan grille...

Страница 38: ...box support 8 Compressor 9 Gas liquid separator 10 Water pump 11 Base plate 12 Right side service plate 13 Heat exchanger 14 Heat exchanger support 15 Front service plate 16 Front panel 17 Fan grille...

Страница 39: ...39 6 2 System Drawing...

Страница 40: ...40 6 3 Dimensions mm KING HEAT 6 9 12 18...

Страница 41: ...alue cut off value MPa 4 6 2 1 Brand Type of Compressor Mitsubishi Twin Rotary Refrigerant R32 Refrigerant Kg 1 5 2 25 2 8 3 9 Brand of Water pump WILO Defrost Auto defrost with 4 way valve Waterproof...

Страница 42: ...ency Ensure the unit has power in the winter whether the unit is used or not Check the power unit and electrical system Check the water system safety valves and exhaust devices are working properly so...

Страница 43: ...he same time you could set the water temperature lower This will basically charge your home during the day so in the evening the home is warm and the heat pump simply maintains the heat This is not co...

Страница 44: ...store or Google market and search Comfort_life download and install the APP then start it 2 Register If you are new user you will need registering Register Input your mobile phone number Get verificat...

Страница 45: ...he blinking will stop when the APP is connected to WiFi Step 2 Now activate the pairing Choose the WiFi network to use enter its password and click Next ATTENTION The Comfort_Life application only sup...

Страница 46: ...ting factory default in the controller can remove device from APP remotely turning off the heat pump and change parameter P87 1 factory default in the controller 4 Controlling Interface as below shown...

Страница 47: ...47 Create a schedule choose the time day s of the week s and the action turn on or off and save 2 Choice of operating modes You can choose between DHW Heating Cooling Heating DHW Cooling DHW modes...