background image

Manual
Weather Sensor u[sonic]WS7 Modbus

(16480.001) u[sonic]WS7 Modbus    

 

      Manual

Advantages at a glance 

 Extremely robust, compact weather sensor made of high-

quality, pollution-resistant anodised aluminium housing

 All-purpose for applications under extreme environmental 

conditions, like deserts, the tropics, arctic areas and high 
mountains

  Version with integrated heating system for icing free opera-

tion all-the-year

 Lamella shelter for accurate measurements of the temper-

ature-humidity sensors

 Modbus data protocol

 Power supply 6...60 VDC with integrated overvoltage 

protection

  Storage, evaluation and display of measured values by using 

the evaluation software “MeteoWare CS3”

 Simple, space-saving assembly on 50 mm standard pipe

The perfect weather sensor

For industrial use as well as under extreme environmen-
tal conditions

6+1 parameters in one 

and at the same time  



Wind direction 



Wind speed



Air temperature



Air humidity



Barometric pressure



Global radiation



+ Dew point temperature (calculated value)

  With independent, integrated sensors for high accura-

cies of each individual parameter

  Without movable measuring elements, i. e. no abrasion, 

low maintenance and very easy to service 

Applications 

    Land applications under any conditions

  Wind turbines

•  

Railway line monitoring

•  

Tra

  c meteorology

•  

Weather services and O

  ces for the Environment 

•  

Chemical and industrial facilities

•  

Power plants, sewage plants and land

fi

 lls

1

Содержание WS7

Страница 1: ...y of measured values by using the evaluation software MeteoWare CS3 Simple space saving assembly on 50 mm standard pipe The perfect weather sensor For industrial use as well as under extreme environme...

Страница 2: ...ing elements This heating is particularly e ective against ice and snow in all climatic zones The measuring principle allows very low starting valuesand high repeat accuracy The sensor rapidly can be...

Страница 3: ...lly the earth screw has to be connected to the ship s ground Acid free contact grease is recommended to protect contact surfaces against corrosion Note Follow all safety instructions while setting up...

Страница 4: ...safety regulations for such works During the electrical installation and termination works the external circuit breaker must be switched o It is not permitted to open those housings by unauthorized pe...

Страница 5: ...sor u sonic WS7 Modbus 16480 001 u sonic WS7 Modbus Manual 5 Dimensional drawings and electrical connections u sonic WS7 Sensor side plug male M12 4 pin or 5 pin shielded Cable side socket female M12...

Страница 6: ...gnificant byte is sent first For values that go beyond one register e g 32 bit this is not clearly specified for the Modbus In these cases 32 bit or 64 bit the LAMBRECHT Modbus sensors follow the big...

Страница 7: ...or supports the corresponding values e g a pure wind sensor does not provide any air humidity The LAMBRECHT sensors give 0xD8F1 0xFF676981 as error code or invalid value 6 7 Holding register Register...

Страница 8: ...rature influence of the shelter 0 1 r h at 10 40 C 3 Shelter inaccuracy 4 r h dependant on v 2 m s and solar radiation 7 Technical data 16480 Weather Sensor u sonic WS7 Modbus Id No 00 16480 001130 Ra...

Отзывы: