LAMBRECHT meteo GmbH
Ser[LOG] Manual
Page 43 of 129
The configuration of the device can be loaded into the Ser[LOG]-Commander with the
function "Call up configuration of logger".
If a station with the same name already exists, the Ser[LOG]-Commander asks whether this
station should be overwritten. An existing configuration can only be overwritten if no write protection is
set and it is not a "factory definition". If the station does not yet exist, it is automatically saved.
If the station or data logger is to be called, a copy of the corresponding data record must be
made. Pressing the button "Copy data set" opens a window in which the station to be copied
can be selected. In the field (after:) underneath the station list, the new name can be as-
signed to the station. The copying process is completed by pressing the
button.
To create a completely new configuration, activate the "New record" function. The
Ser[LOG]-Commander then switches to an "empty" configuration window. In this mode, the
"Data Logger" selection box is an input field in which you can enter the name of your station
or Ser[LOG]. In the field "Station number" enter the number under which the device should be accessi-
ble.
Note: If a network is operated with several Ser[LOG], the station number must be unique. It is
the key with which the logger is addressed.
By pressing the button "Save data set" the new station is created and saved in the Ser[LOG]-
Commander. After the station has been saved, the Ser[LOG]-Commander returns to the
normal configuration window and the field "Data logger" becomes a selection field again.
5.3.2
Activating AnDiMod Extension Modules
If AnDiMod modules are connected to the Ser[LOG], they must be activated with the Ser[LOG]-Com-
mander!
The number of measuring modules can be set in the frame "Analog Measuring Modules". With a
Ser[LOG], the number of measurement modules is set to "0". With a Ser[LOG]Plus, an AnDiMod meas-
urement module is already integrated in the housing. Therefore, check whether the number of meas-
urement modules in the Ser[LOG]Plus is set to "1".
Note:
When creating a new data set, the number of measuring modules is initially set to "0".
The setting of the number of measurement modules used has a considerable influence on the following
configuration options of the measurement channels.
Note: If AnDiMod modules have been activated in the Ser[LOG]-Commander but are actually not
connected, this leads to a critical system error when the Ser[LOG] system is switched on.
5.3.3
Setting the measured value acquisition
In the "Operating modes" frame, you can define the time for averaging. The averaging time is also the
storage interval in which the Ser[LOG] saves the measured values. By default, the averaging time is set
to "10 min". Values between 1 minute and 60 minutes can be set. To ensure the best compatibility for
further processing programs, it is recommended to set the time interval to 1 minute or to 10 minutes.
The storage always takes place at the full minute interval after the set local time.
Currently, only the standard measuring interval in 1 Hz cycle or 2 Hz cycle is available for selection as
operating mode.
In addition to the average values, the extreme values, i.e. the minimum and maximum values of the
respective interval can be saved. If extreme values are to be saved, please activate the "Extreme value
storage" field.
Содержание Ser[LOG]
Страница 9: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 9 of 129 21 Technical data 127 22 Disposal 129...
Страница 68: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 68 of 129 This choice leads to the following graph...
Страница 92: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 92 of 129 12 Managing the safety settings...
Страница 101: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 101 of 129...
Страница 102: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 102 of 129...
Страница 103: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 103 of 129...
Страница 104: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 104 of 129...
Страница 105: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 105 of 129...
Страница 106: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 106 of 129...
Страница 107: ...LAMBRECHT meteo GmbH Ser LOG Manual Page 107 of 129...