background image

(15189) Precipitation Sensor 

  

 

Operating Instructions 

Operating Instruction
Precipitation Sensors (15189) + (15189 H)

Features

  Precipitation sensor for automatic weather stations 

  Exchangeable, weighing tipping bucket system according to Joss-Tognini

  2 cm³ (2 g water) tipping bucket for precise precipitation measuring in regions with normal rain falls

  4 cm³ (4 g water) tipping bucket for precise precipitation measuring in regions with heavy rain falls/ tropical rain

• 

Connectable to external data logger, e. g. TROPOS

 Winter-

fi

 t model (15189 H) with electronically controlled 2-circuit heating 

  Weatherproof materials (anodized aluminium, stainless steel) guarantee a long durability

  Funnel according to the WMO Standard No. 8

1

Содержание 15189

Страница 1: ...er tipping bucket for precise precipitation measuring in regions with normal rain falls 4 cm 4 g water tipping bucket for precise precipitation measuring in regions with heavy rain falls tropical rain...

Страница 2: ...ng plate C must be pushed back Now insert the tipping bucket F Make sure that the magnet E attached at the middle wall of the tipping bucket rests under the capsule with the embedded reed contact D Fi...

Страница 3: ...ket F Tipping bucket Mounting of the protective covering When mounting the protective covering please make sure that the sign close open close to is positioned above the fixing screw Especially when u...

Страница 4: ...ut For this application the clamps 1 and 6 are used In this case the current supply of the electronics with 100 A is not necessary The LAMBRECHT meteo data logger TROPOS is equipped with such a bounce...

Страница 5: ...h 100 2 bucket tippings should have counted Rinse the sensor thoroughly for cleaning Clinging particles of dirt in the collecting funnel or outlet pipe may be removed with a piece of wood If unsatisfy...

Страница 6: ...9 Precipitation Sensor Operating Instructions Operating Instruction Precipitation Sensors 15189 15189 H with heating without heating Connecting diagrams for use of the bounce free signal output standa...

Страница 7: ...15189 Precipitation Sensor Operating Instructions Operating Instruction Precipitation Sensors 15189 15189 H with heating without heating Connecting diagrams to data logger TROPOS 7...

Страница 8: ...on of the LAMBRECHT meteo GmbH for changes of system components These activities must be operated by a qualified technician 7 Prevent the ingress of liquids into the devices without permission Technic...

Отзывы: