01

The aluminum kit contains a set of Servicing Equipment.

A

  Face fixture (two parts)

B  

Pressure gauge (0-6kPa)

C

  Foot pump (with multi-valve adaptor)

D

 

Glue and applicator (two pieces)

1.  Adjust the air-pressure test cevice on the immersion suit

1. Lay the immersion suit on a work table and check for damages.

3. Place Face Fixture (Part 2), by adjusting its holes 

carefully through the bolts and joints.

2. Place Face Fixture (Part 1) inside the immersion suit hood area 

and zip up. 

Attention:

 Stretch the hood fabric by pulling it to the 

direction of arrows. The hood should not have any folds.

4. Above is an example image of assembled face fixtures with 

hood. 

Attention: 

The zipper head should pass through the hole.

for the air- pressure test & repair of immersion suits

Inspection Device for Immersion suits

Instruction process

 

 

Part 1, Face Fixture

Part 2, Face Fixture

 

 

70168

LALIZAS

Содержание 70168

Страница 1: ... Part 2 by adjusting its holes carefully through the bolts and joints 2 Place Face Fixture Part 1 inside the immersion suit hood area and zip up Attention Stretch the hood fabric by pulling it to the direction of arrows The hood should not have any folds 4 Above is an example image of assembled face fixtures with hood Attention The zipper head should pass through the hole for the air pressure test...

Страница 2: ...tion of pressure gauge Dial surface Pointer 9 Install the Connector for the foot pump by pressing down the proper joint so as to insert it properly 10 Adjust the multi valve adaptor on the connector of face fixture 8 Insert the Pressure Gauge at face fixture socket at the same time press down the joint and secure the connection between them L A L I Z A S ...

Страница 3: ...water solution 3 Check carefully if any bubbles appear from the Immersion Suit and mark properly the leaking areas of the suit 3 Repair procedure 1 Adapt the applicator on the glue tube for use Remove the air test device and clean the suit thoroughly with fresh water and dry it trying to leave the marks visual A Repair of seams and closures 2 Above is an example image of assembled face fixtures wi...

Страница 4: ...ry for 8 hours 2 Let it dry for 8 10 minutes Then apply once again a glue layer on both sides of Immersion suit s damaged area C Mark the Service Date on the Immersion Suit In case that the version of the Immersion Suit indicates a Service Table mark the service date on it Air Pressure Test Otherwise just mark on the indicated area of the suit the Date of the Air Test and the Type of Service e g S...

Отзывы: