Maximum Flow Ranges: 

 

 

• 

T2C-075 ¾" Inlet/Outlet

0 to 25 US gpm

(0 to 5.7 m³/hr)

• 

T2C-100 1" Inlet/Outlet 

0 to 39 US gpm

(0 to 8.9 m³/hr)

• 

T2C-150 1 

1/2"

 Inlet/Outlet 

0 to 78 US gpm

(0 to 17.7 m³/hr)

Maximum Pressure:

• 

100 psi at 73˚F

       (6.9 bar at 38˚C)

Temperature Range:

• 

32˚F - 120˚F

       (0˚C - 49˚C)

Mesh Sizes:

• 

30 Mesh (600 Micron)  

Element (Brown)

• 

60 Mesh (250 Micron)  

Element (White)

• 

100 Mesh (150 Micron) 

Element (Gray)

• 

140 Mesh (105 Micron) 

Element (Black)

Pre-Installation Checklist 

A.  Select a good filter location:
 

 

Install on the pressure (outlet) side of any pumps

 

 

In a vertical position with Purge Exit pointing down 

 

 

 

Away from extreme weather conditions to protect from freezing

 

 

At least 12 inches away from walls, etc. so top handle can be twisted

 

 

Allow enough clearance beneath the unit to: 

 

 

(a)  attach a purge drain hose to the Purge Exit (recommended) 

 

 

(b)  remove the clear bowl assembly, to allow replacement of element as needed

B.   As a sunny outdoor installation might lead to algae growth inside the clear bowl and

 

affect the operation of your TWIST

II

CLEAN. An optional Sun Shield is available.

Safety Notes:

Despite the ease of installation and operation of the LAKOS TWIST

II

CLEAN product, certain 

precautions should be taken.

1.  Lubricate “O” rings with NSF approved silicon grease only - Dow 111 is recommended.

2.  Do not overtighten the threaded connections. Do not tighten more than a 1/4 turn past finger 

tight. Hand tighten the bowl, do not use tools.

3.  Do not use wrenches on plastic filter parts. Use of tools on filter will void warranty.

4.  For threaded connections, use the Teflon™ tape sealant provided with product.

5.  Filter components that have “O” rings do not require thread sealant.

6.  Remove clear bowl if the filter is to be installed using any solvent welding. This will prevent 

solvent damage to the clear bowl.

7.  This filter is designed for use with water only. Other chemicals or components can damage the 

filter components. Evaluate all chemicals for proper usage with the filter.

8.  Protect unit from freezing, as you would with any other water supply lines.

9.  Follow all local and state codes, laws, and regulations when installing any filter.

Top Handle

Red Safety Latch

Inlet

Outlet

Flow Direction Arrow

Mounting 

Eyelets

Clear Bowl

Filter Element

Purge Exit

If for any reason the filter element does not clean completely during the normal Twist to Clean 

operation, manual cleaning may be needed. In this case, remove the bowl and clean the element with 

a soft brush, brushing and running water across element.

Caution:

 If the filter bowl is to be removed, all water flow must be shut off going to the filter. 

Maintenance and Troubleshooting

Limited Warranty

The LAKOS TWIST

II

CLEAN

 

is warranted to be free of material or workmanship defects for at least one year 

from delivery date. 

If a fault develops, notify us, giving a complete description of the alleged malfunction. Include the model 

number(s), date of delivery and operating conditions of subject product(s). We will subsequently review this 

information and, at our option, supply you with either servicing data or shipping instruction and returned materi-

als authorization. Upon prepaid receipt of subject product(s) at the instructed destination, we will then either 

repair or replace such product(s), at our option, and if determined to be a warranted defect, we will perform  

any products, damages or injuries resulting from misuse, neglect, normal expected wear, chemically-caused 

corrosion, improper installation or operation contrary to factory recommendation. Nor does it cover equipment 

that has been modifed, tampered with or altered without authorization. No other extended liabilities are stated 

or implied and this warranty in no event covers incidental or consequential damages, injuries or costs resulting 

from any such defective product(s).

LS-866 (Rev. 3/11)

Inlet/Outlet

 to

 Purge

 Port

Total
 Length

TWIST

II

CLEAN

Installation Instructions for

     3/4-inch Model T2C-075

     1-inch Model T2C-100

     1 1/2-inch Model T2C-150

Quick-Star

t Guide

Width

Dimensions

Total

Flow Rate (US gpm)

Flow Rate (m

3

/hr)

Clean Conditions

Head Loss (Bar)

Head Loss (psi)

=Recommended flow range

2.0

4.0

6.0

8.0

10.0

12.0

14.0

16.0

18.0

0

10

20

30

40

50

60

70

80

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

www.TWIST

II

CLEAN.com

0

1

2

3

4

5

6

7

8

9

10

T2C-075 T2C-100

T2C-150

Max Flow=   