108
c
HAPTER
6:
Computer Interface Operation
Model 350 Temperature Controller
6.2.4 Status System
Overview
The Model 350 implements a status system compliant with the IEEE-488.2 standard.
The status system provides a method of recording and reporting instrument informa-
tion and is typically used to control the Service Request (SRQ) interrupt line. A dia-
gram of the status system is shown in FIGURE 6-1. The status system is made up of
status register sets, the Status Byte register, and the Service Request Enable register.
Each register set consists of three types of registers: condition, event, and enable.
6.2.4.1 Condition Registers
Each register set (except the Standard Event Register set) includes a condition regis-
ter as shown in FIGURE 6-1. The condition register constantly monitors the instru-
ment status. The data bits are real-time and are not latched or buffered. The register
is read-only.
6.2.4.2 Event Registers
Each register set includes an event register as shown in FIGURE 6-1. Bits in the event
register correspond to various system events and latch when the event occurs. When
an event bit is set, subsequent events corresponding to that bit are ignored. Set bits
remain latched until the register is cleared by a query command (such as *ESR?) or a
*CLS command. The register is read-only.
6.2.4.3 Enable Registers
Each register set includes an enable register as shown in FIGURE 6-1. An enable regis-
ter determines which bits in the corresponding event register will set the summary
bit for the register set in the Status Byte. You may write to or read from an enable reg-
ister. Each event register bit is logically ANDed to the corresponding enable bit of the
enable register. When you set an enable register bit, and the corresponding bit is set
in the event register, the output (summary) of the register will be set, which in turn
sets the summary bit of the Status Byte register.
Содержание 350
Страница 4: ...Model 350 Temperature Controller ...
Страница 6: ......
Страница 14: ...Model 350 Temperature Controller ...
Страница 28: ...14 cHAPTER 1 Introduction Model 350 Temperature Controller ...
Страница 53: ...Examples of PID control 2 13 4 ManualOutput 39 www lakeshore com FIGURE 2 4 ...
Страница 58: ...44 cHAPTER 2 Cooling System Design and Temperature Control Model 350 Temperature Controller ...
Страница 118: ...104 cHAPTER 5 Advanced Operation Model 350 Temperature Controller ...
Страница 178: ...164 cHAPTER 7 Options and Accessories Model 350 Temperature Controller ...
Страница 192: ...178 cHAPTER 8 Service Model 350 Temperature Controller ...