10
the controller you need to save to FLASH. Otherwise settings will be lost at power down, ref Section
3.2.
Click
RETRIEVE
to upload settings from the controller board.
Input
Displays live feedback from the controller board, calculated with user settings to indicate values.
Regulator Information
Displays the set point and temperature point used in the regulator control loop.
Output
Displays controlled output values to main output, fan 1 and fan 2. The unit of measure for main is in
percent with range between -100% to +100%. The unit of measure for fans is in volts with range
between 0 to 60 Volts.
5. User Tabs
There are six tabs that the user can reference to change parameters in controller and visually monitor
parameters. All data is saved in the setting file *.sc type.
5.1 Base
Base tab allows for quick setup of the regulator. Select temperature sensor, set point and enter
description information under notes to recall settings for future reference. All data will be stored in the
file.