BL600-Sx Hardware Integration Guide
Single Mode BLE Module
Americas: +1-800-492-2320 Option 2
Europe: +44-1628-858-940
Hong Kong: +852-2923-0610
www.lairdtech.com/bluetooth
44
CONN-HIG-BL600
Item
Part Number
Mfg.
Type
Gain (dBi)
Model
1
AT5020-E3R0HBANT/LF
ACX
Ceramic
0
BL600-SA
2
EDA-8709-2G4C1-B27-CY
MAG. Layers
Dipole
2.0
BL600-SC
3
PCA-4606-2G4C1-A33-CY
MAG. Layers
Dipole
2.21
BL600-SC
4
EDA-8709-2G4R2-A40-CY
MAG. Layers
Dipole
2.0
BL600-ST
Note:
The OEM is free to choose another vendor’s antenna of like type and equal or lesser gain as an
antenna appearing in the table and still maintain compliance. Reference FCC Part 15.204(c)(4) for
further information on this topic.
To reduce potential radio interference to other users, the antenna type and gain should be chosen so
that the equivalent isotropic radiated power (EIRP) is not more than that permitted for successful
communication.
9.1
Power Exposure Information
Federal Communication Commission (FCC) Radiation Exposure Statement:
This EUT is in compliance with SAR for general population/uncontrolled exposure limits in ANSI/IEEE
C95.1-1999 and had been tested in accordance with the measurement methods and procedures specified in
OET Bulletin 65 Supplement C.
This transceiver must not be co-located or operating in conjunction with any other antenna, transmitter, or
external amplifiers. Further testing / evaluation of the end product will be required if the OEM’s device violates
any of these requirements.
The BL600 is fully approved for mobile and portable applications.
9.2
OEM Responsibilities
WARNING:
The OEM must ensure that FCC labelling requirements are met. This includes a clearly visible label
on the outside of the OEM enclosure specifying the appropriate Laird Technology FCC identifier
for this product.
Contains FCC ID: PI4xxxxx IC: 1931B-xxxxx
If the size of the end product is larger than 8x10cm, then the following FCC part 15.19 statement
has to also be available on visible on outside of device:
The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) This device must
accept any interference received, including interference that may cause undesired operation
Label and text information should be in a size of type large enough to be readily legible, consistent with the
dimensions of the equipment and the label. However, the type size for the text is not required to be larger
than eight point.
CAUTION: The OEM should have their device which incorporates the BL600 tested by a qualified test house
to verify compliance with FCC Part 15 Subpart B limits for unintentional radiators.
CAUTION: Any changes or modifications not expressly approved by Laird Technology could void the user’s
authority to operate the equipment.
Note:
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection