background image

 

23 

JACKPOT DISPLAY ADJUSTMENTS (P16 – P27) 

 

!"

P16 = INITIAL JACKPOT WINNING SCORE 

 

(Default 120) (Adjustable 10 – 500) 

 

This is the winning score that the jackpot reverts back to after a jackpot is won. If 
the jackpot is set to ‘

FIXED’

, this is the score the jackpot will remain at. 

(Refer 

to Programmable game adjustments P18 and P19). 

 

!"

P17 = CURRENT JACKPOT WINNING SCORE

 

(Default 120) (Adjustable 10 – 500) 

 

This is the current Jackpot Winning Score, and can be adjusted up or down by the 
operator. Changing this score will not effect the setting of P18 and P19 (fixed or 
decrementing). After a jackpot is won, the jackpot score will revert to the “Initial 
Jackpot Winning Score” 

(Programmable game adjustment P16).

 

 

!"

P18 = JACKPOT WINNING SCORE (Fixed / Decrement)

 

(Default 1) (Adjustable 0 – 10) 

 

This adjustment allows the Jackpot Winning Score to be fixed [ 0 ] or to 
decrement [ 1 – 10 ]. If set to fixed [ 0 ], the jackpot score that is needed to win 
will remain constant and not change. By setting this adjustment from 1 – 10, the 
score will decrement by the set amount every so many games, depending on the 
settings of Programmable game adjustment P19.  

 

For example:

 If P18 = 1 and P19 = 20, the jackpot score will reduce by 1 point 

every 20 games. 

 

!"

P19 = NUMBER OF GAMES BEFORE JACKPOT SCORE 
DECREMENTS 

(Default 20) (Adjustable 1 – 100)

 

 

This is the number of games that must be played before the Jackpot Winning 
Score decrements. 

Refer Programmable game adjustment P18. 

 

!"

P20 = MINIMUM JACKPOT SCORE 

(Default 50) (Adjustable 0 – 100)

 

 

This is the minimum score level that the jackpot can decrement to.

 

 

!"

P21 = INITIAL JACKPOT TICKETS 

 

(Default 100) (Adjustable 10 – 9990 in steps of 10) 
 
This is the number of tickets the jackpot reverts back to after a jackpot is won. If 
the jackpot tickets’ setting is fixed, this is the number of tickets the jackpot will 
remain at. 

(Refer to Programmable game adjustment P23 and P24). 

 

!"

P22 = CURRENT JACKPOT TICKETS 

 

(Default 100) (Adjustable 10 – 9990 in single steps) 

 

This is the current number of jackpot tickets and can be adjusted up or down by 
the operator. Changing this value will not effect the setting of Programmable 
game adjustments P23 and P24 (fixed or incrementing) and after a jackpot is won, 
the jackpot tickets will revert to the “initial Jackpot Tickets” setting (P21). 

Содержание Slam 'n' Jam Overhead Display

Страница 1: ......

Страница 2: ...Indonesia New Zealand USA LEISURE ALLIED INDUSTRIES Correspondence regarding this machine should be addressed to your closest LAI Games Distributor or Leisure and Allied Industries office For a list o...

Страница 3: ...POWER UP SEQUENCE 11 TROUBLESHOOTING THE LINK SYSTEM 13 OPERATION 15 Display Mode 15 Test Mode 15 PROGRAMABLE ADUSTMENTS MODE 16 Programmable Adjustments Quick Reference Table 18 Programmable Adjustme...

Страница 4: ...Location Diagrams 29 MAINTENANCE CLEANING 30 SECTION B TECHNICAL DETAILS MAINS VOLTAGE ADJUSTMENT 31 OVERHEAD DISPLAY PARTS LIST 32 WIRING DIAGRAMS 34 Main Display Wiring 34 Power Distribution 35 WAR...

Страница 5: ...us ticket amount is also programmable and can increment automatically if required For more information refer to the Programmable Adjustment section of this manual PACKAGING DELIVERY At delivery the Di...

Страница 6: ...V 220V 240V AC 50 60Hz mains electric supply LOCATION REQUIREMENTS Ambient temperature between 5o C and 40o C Ambient humidity Low Ambient U V radiation Very low Vibrations level Low NOTE BEWARE Befor...

Страница 7: ...OT Subject the Overhead Bonus Jackpot Display to extreme temperature variations Reliability of electrical components deteriorates rapidly over 60o C DO NOT Expose the game logic boards to U V radiatio...

Страница 8: ...ed on the surface floor ground etc Make sure that grounding connections are made safe Do not use any fuse that does not meet specified rating Make complete connections for the IC Board and other conne...

Страница 9: ...an odd number of machines The mounting brackets and the fitting of the brackets are the same for both an odd and even bank of machines The difference is in the position where they are bolted onto the...

Страница 10: ...with the four 6mm x 40mm Allen head bolts supplied as per Figure 2 STEP Two Attachment of Brackets FIGURE 1 FIGURE 2 Loosely bolt the two brackets in position on top of these longer bolts using the nu...

Страница 11: ...erneath When aligned and in position tighten all the bolts STEP Four Connection of Test Switch Box Link Cables Screw the test switch box inside the machine for easy access Feed the test switch box cab...

Страница 12: ...AD DISPLAY 2 MACHINES OVERHEAD DISPLAY IN OUT 2 IN OUT 1 SLAVE SLAVE OVERHEAD JACKPOT DISPLAY OUT IN MASTER 3 MACHINES OVERHEAD DISPLAY IN OUT 3 IN OUT 2 IN OUT 1 SLAVE SLAVE SLAVE OVERHEAD JACKPOT DI...

Страница 13: ...T 3 IN OUT 2 IN OUT 1 SLAVE SLAVE SLAVE SLAVE 4 MACHINES OVERHEAD DISPLAY OVERHEAD JACKPOT DISPLAY OUT IN MASTER OVERHEAD JACKPOT DISPLAY OUT IN MASTER 5 MACHINES OVERHEAD DISPLAY IN OUT 5 IN OUT 4 IN...

Страница 14: ...2 IN OUT 1 SLAVE SLAVE SLAVE SLAVE SLAVE SLAVE 6 MACHINES OVERHEAD DISPLAY OVERHEAD JACKPOT DISPLAY OUT IN MASTER 7 MACHINES OVERHEAD DISPLAY IN OUT 6 IN OUT 5 IN OUT 4 IN OUT 3 IN OUT 2 IN OUT 1 IN O...

Страница 15: ...e done the machines should link when powered up If you have any problems with linking refer to Troubleshooting the Link System Page 13 of this manual GAME POWER UP SEQUENCE Below is an example of the...

Страница 16: ...SLAVE SLAVE SLAVE SLAVE SLAVE SLAVE SLAVE SLAVE 0 0 0 7 MACHINE 3 DIGIT DISPLAYS MASTER 0 1 2 0 0 3 0 4 1 2 3 5 6 8 SLAVE SLAVE SLAVE SLAVE SLAVE SLAVE SLAVE SLAVE L L L L L L L L L L L L L L L L L L...

Страница 17: ...and ALL the game machines are SLAVE MACHINES Program adjustment P01 By checking what the displays show on POWER UP can help diagnose where a break or bad connection in the link could be Refer to diag...

Страница 18: ...OUT to IN as per the diagram below Turn the single machine off and on and the 3 digit display should show the following sequence If an error occurs this would mean that the single link cable is fault...

Страница 19: ...The Test Mode has two test configurations allowing you to test the function of the Lamps and Displays and the Test Switches PROGRAMMABLE ADJUSTMENTS MODE audits MODE Press TEST Press TEST Press TEST...

Страница 20: ...riable of the game and any value in this range can be chosen for the game settings using the change procedure Press TEST 5 0 P 0 3 Press SERVICE NUMBER OF COINS MECH 1 1 2 3 10 to change value Press S...

Страница 21: ...g from the display P01 being the first step continuing through to P27 and then looping again from P01 to P27 until the mode is exited CHANGE The Start Step button is pressed to change the displayed va...

Страница 22: ...20mins in 15min steps 15 30 45 120 30 Double Tickets Random Start Time Adjustment P15 1 5mins in 1 min steps 1 2 3 5 3 Double Tickets Lamp On Time P16 10 500 10 11 12 500 120 Initial Jackpot Winning S...

Страница 23: ...adjustment P03 P03 LINK GAME WINNER BONUS AMOUNT default 5 Adjustable 1 10 Credits or 1 100 Tickets Depending on P02 Setting This game adjustment allows the operator to set the number of bonus credit...

Страница 24: ...ault 01 Adjustable ON 1 or OFF 0 This adjustment turns the attract mode sound ON 01 or OFF 0 This is the sound and music that the game generates to attract customers when it is not being played The mu...

Страница 25: ...cket lamp on the front of the machine will randomly flash If a customer inserts a coin during this period the tickets that they would normally win on their game will be doubled P13 DOUBLE TICKETS WAIT...

Страница 26: ...ETS LAMP ON TIME default 3 Adjustable 1 5 minutes in 1 minute steps This is the time period that the Double Tickets lamp will flash for when it becomes active Wait period Random start time If no game...

Страница 27: ...mount every so many games depending on the settings of Programmable game adjustment P19 For example If P18 1 and P19 20 the jackpot score will reduce by 1 point every 20 games P19 NUMBER OF GAMES BEFO...

Страница 28: ...t 1000 Adjustable 10 9990 steps of 10 This is the maximum number of tickets that the jackpot tickets can increment to P26 JACKPOT TICKETS PAYOUT Auto Manual Default 1 Adjustable 1 Auto 0 Manual This s...

Страница 29: ...then looping again from A1 to A6 until the mode is exited RESET Audits A01 A03 can be reset during any of the SIX audit configurations by holding the Stop button for longer than 5 seconds The display...

Страница 30: ...NNING SCORE This Audit displays the Last Winning Jackpot Score that was won A05 LAST JACKPOT TICKETS WON This Audit displays the Number of Tickets that were won on the last Jackpot A06 NUMBER OF GAMES...

Страница 31: ...ay only has two errors These are listed as follows CODE ERROR DESCRIPTION SOLUTION Er3 EEPROM ERROR Problem with on board EEPROM Send MCU PCB to the closest LAI office for repair Er4 LINK ERROR Ref to...

Страница 32: ...d is positioned on the Rope light chaser PCB POWER REGULATOR PCB 1 x 1 AMP Fast Blow This fuse is for protection of the 12V DC Supply to the PCB s POWER REGULATOR PCB 1 x 3 AMP Fast Blow This fuse of...

Страница 33: ...SECTION A SERVICE INSTRUCTIONS Please read these instructions carefully before servicing this machine...

Страница 34: ...TE FLURO PARTS LOCATION DIAGRAM As viewed from front FLURO BALLAST STARTERS 20W 40W 15W FLURO BALLAST STARTERS 20W 40W 20W COOL WHITE BULLET FLURO PARTS LOCATION DIAGRAM As viewed from rear POWER TRAN...

Страница 35: ...h INTERIOR Regularly dust and vacuum the interior of the cabinet taking care to remove any objects that may have fallen on the PCBs Check and tighten all fixing hardware and fasteners as required CAUT...

Страница 36: ...It is advised that anybody using SECTION B for repairing or modifying any of the components of the game should be a qualified technician having at least a basic knowledge of digital components integra...

Страница 37: ...ewed from the rear If unsure of the location of either transformer refer to Parts location diagram on page 27 of this manual Change the position of the ACTIVE or HOT WIRE input marked brown on the dia...

Страница 38: ...P EA0614 Transformer Multi Tap 10 21VAC 3A SP EA0812 Transformer Multi Tap 2 X 110VAC 3A SP EA0816 Lampu Neon 15W Cool White Fluorescent Lamp SP EA0205 Lampu Neon 20W Cool White Fluorescent Lamp SP EA...

Страница 39: ...ect 6 8mm SP EP0604 HARDWARE ASSEMBLY SNJ OBD Main Housing Assy SP HA1670 SNJ OBD Base Mounting Bracket Left SP HA1672 SNJ OBD Base Mounting Bracket Right SP HA1673 SNJ OBD Double Ballast Bracket SP H...

Страница 40: ......

Страница 41: ......

Страница 42: ...uding parts LAI shall have no obligation to make repairs necessitated by negligence or interference to any component by any unauthorized personal This will automatically void any existing warranty In...

Страница 43: ...Pte Ltd Tel 65 6 261 9446 15 Fourth Chin Bee Rd Fax 65 6 261 6674 SINGAPORE 619703 e mail laigames leisure com sg http www laigames com LAI GAMES OFFICES LAI GAMES DISTRIBUTORS For the latest list of...