43
3.
Attach a piece of paper to the table with scotch tape/masking tape in the area covered by
the blade guide.
4.
Lower the guide and mark its position on the paper. This will give you a reference point to
work from.
5.
Move the guide up and down and note any change in the relationship between the blade
and the guide (both side and back).
6.
Only if adjustment is needed, loosen the two bolts on the guide plate and move the guide
back/forward, left/right, depending on the adjustment needed.
7.
Tighten the two bolts on the guide plate and move the guide up and down, noting the
relationship between the blade and the side and back guide.
8.
If the adjustment needs to be refined, repeat the procedure.
Troubleshooting
Bandsaw will not start
1.
Check that the start switch is being fully depressed.
2.
Check that the red stop switch is fully out.
3.
Check that the electrical power cord is plugged into the power outlet.
4.
Check that the electrical supply is on (reset the breaker).
5.
Check that the earth wire is wired correctly.
7.
With the power disconnected from the machine, check that the wiring in the terminal box
is correct.
Check that the rubber insulation is stripped enough and is not causing a bad connection.
Check that all the screws are tight.
8.
Test the safety circuit. With the power disconnected from the machine, use a multi-
meter/circuit tester to check that there is continuity between 5L3 (red wire) and the red wire
beside 2T1. To gain access to the terminals, you will have to remove the switch plate from
the front of the switch box. This circuit is a loop that has the foot brake and stop switch. It is
designed to be fail-safe, and any switch that is not functioning or set correctly will cause the
machine to not start. If there is no continuity, you will have to trace the switch that is open or
faulty and correct the fault.
9.
Check that you have the correct power: 220V, not 110V.
The machine will not stop
This is a very rare occurrence as the machine, is designed to be fail-safe. If it should occur
and you cannot fix the fault, seek professional assistance. The machine must be
disconnected from the power and never run until the fault has been rectified.
1.
Stop switch faulty. Replace the stop switch.
Содержание LT14 series
Страница 1: ...2072 Alton Parkway Irvine CA 92606 www lagunatools com 800 234 1976...
Страница 9: ...9 Screws etc Leveling bolts Allen keys Tool holder Mobility bracket...
Страница 47: ...47...
Страница 48: ...48...
Страница 49: ...49...
Страница 50: ...50...
Страница 51: ...51...
Страница 52: ...52...
Страница 53: ...53...
Страница 54: ...54...