GROUNDING INSTRUCTIONS
1. All grounded, cord-connected tools:
In the event of a malfunction or breakdown, grounding provides a path of least resistance for
electric current to reduce the risk of electric shock. This tool is equipped with an electric cord
having an equipment-grounding conductor and a grounding plug. The plug must be plugged into a
matching outlet that is properly installed and grounded in accordance with all local codes and
ordinances.
Do not modify the plug provided – if it will not fit the outlet, have the proper outlet installed by a
qualified electrician.
Improper connection of the equipment-grounding conductor can result in a risk of electric shock.
The conductor with insulation having an outer surface that is green with or without yellow stripes is
the equipment-grounding conductor. If repair or replacement of the electric cord or plug is
necessary, do not connect the equipment-grounding conductor to a live terminal.
Check with qualified electrician or service personnel if the grounding instructions are not
completely understood, or if in doubt as to whether the tool is properly grounded.
Use only 3-wire extension cords that have 3-prong grounding plugs and 3 pole receptacles that
accept the tool's plug.
Repair or replace damaged or worn cord immediately.
2. Grounded, cord-connected tools intended for use on a supply circuit having a nominal rating less
than 150 volts:
This tool is intended for use on a circuit that has an outlet that looks like the one illustrated in
Sketch A in Fig. 1. The tool has a grounding plug that looks like the plug illustrated in Sketch A in
Fig. 1. A temporary adapter, which looks like the adapter illustrated in Sketch B and C, may be
used to connect this plug to a 2-pole receptacle as shown in Sketch B if a properly grounded
outlet is not available. The temporary adapter should be used only until a properly grounded outlet
can be installed by a qualified electrician. This adapter is not permitted in Canada. The green-
colored rigid ear, lug, and the like, extending from the adapter, must be connected to a permanent
ground such
as a properly grounded outlet box.
3. Grounded, cord-connected tools intended for use on a supply circuit having a nominal rating of
150–250 volts, inclusive:
This tool is intended for use on a circuit that has an outlet that looks like the one illustrated in
Sketch D. The tool has a grounding plug that looks like the plug illustrated in Sketch D on next
page. Make sure the tool is connected to an outlet having the same configuration as the plug. No
adapter is available or should be used with this tool. If the tool must be reconnected for use on a
different type of electric circuit, the reconnection should be made by qualified service personnel;
and after reconnection, the tool should comply with all local codes and ordinances.