Remove the autoclean motor capacitor (6uF/250VAC) by disconnecting the two yellow connectors and
replace it with the auto clean motor capacitor (1.5uF/450VAC). Make sure the two yellow connectors are
connected in the same location as shown below. Always connect on the same side.
Figure 11: Replacing Capacitor
Figure 12: Replacing Capacitor
6.
Remove the 25A overload protector from the front control panel by first removing the two connectors.
Figure 13: Removing 110V Overload Protector
7. Loosen the bolt holding the onboard Overload Protector using a wrench.