HEAD RETURN STROKE LIMITING DEVICE
To carry out this operation you must:
1. Slightly open regulator.
2. Rotate the selector (5) either to the right or left to lower or lift the motorhead.
3. Position the secure mechanical stop (8) against upper plate of the cylinder to press
against the upper limit switch.
4. The lower limit switch (9) is set during assembly and inspection and limits the lower
stroke of the motorhead.
ATTENTION:
It is not necessary to adjust the upper end-stroke every time:
•
You can bring the blade near the workpiece by means of the selector (5) and then start
the automatic cutting cycle which will take place from the actual position of the blade.
•
Notice that once the cut is complete the motorhead will go to the upper endstroke.
•