background image

Model ACU100      User Instructions

[email protected]  .  Phone: (765) 423-1505

Model ACU100

Lafayette Range of 

Motion Inclinometer  

User Instructions

3700 Sagamore Pkwy N

Lafayette, IN 47904 USA

Tel:   (765) 423-1505

[email protected]    

www.lafayetteinstrument.com

© 2023 by Lafayette Instrument Company, Inc. All Rights Reserved- 

Rel. 3.21.23

Содержание ACU100

Страница 1: ...423 1505 Model ACU100 Lafayette Range of Motion Inclinometer User Instructions 3700 Sagamore Pkwy N Lafayette IN 47904 USA Tel 765 423 1505 info lafayetteinstrument com www lafayetteinstrument com 202...

Страница 2: ...nstrument reproducibility Range of motion in three axis left to right L R front to back F B and rotation ROT Data storage for up to 250 tests in on board memory Storage of data on button press Measure...

Страница 3: ...dversely affect scores Extreme temperature especially heat may affect the values obtained Large magnetic fields could affect the calibration or readings Care should be taken not to drop the ROMI The p...

Страница 4: ...ght or left hand operation The MENU SELECT allows you to enter into the Menu screen and select various options within it 2 3 NAVIGATION Buttons While on the Test screen the NAVIGATION buttons are used...

Страница 5: ...ile a test is being displayed 7 Axis of Rotation Displays the axis of the current test relative to the device ROT Rotation around the device F B Front to back orientation L R Left to right orientation...

Страница 6: ...vice connects to the companion unit the screen on the companion will display Connected To Peer Device Once connected navigate back the test menu on the main device and run normal tests now using both...

Страница 7: ...tions menu allows user to customize the setup of their unit WIRELESS Toggles on off the module for wireless connection BACKLIGHT Toggles unit s backlight on off SOUND Toggles unit s sound on off BUTTO...

Страница 8: ...ew seconds to allow the accelerometer to calibrate Make sure that there is slow movement between 2 stable positions The 6 stable positions could be in any direction but make sure that the device is ly...

Страница 9: ...3 When individual reaches maximum range of motion press the left base button to store the maximum left cervical later bending angle 4 Ask individual to return to neutral position 5 Repeat measurement...

Страница 10: ...charger into your computer and downloading the current version of the firmware via the Firmware Updater Inclinometer Cleaning Hard surfaces can be cleaned with a bleach free sanitizing wipe Alcohol wi...

Страница 11: ...enerates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guaran...

Страница 12: ...Fragile handle with care Indicates device that needs careful handling ISO 15223 1 2016 Ref 5 3 1 Keep away from sunlight Indicates a device needs protection from sunlight ISO 15223 1 2016 Ref 5 3 2 Te...

Страница 13: ...original invoice for the instrument is issued to a company that is not the company of the end user and not an authorized Lafayette Instrument Company distributor then all requests for warranty must b...

Отзывы: