Safety When Using Oxygen

Build-up and transfer of high pressure to the 
patient is prevented as excess oxygen is vented 
to the atmosphere over the outlet valve. 

If the reservoir bag remains flat during the whole 
ventilation cycle, it is a a visual indication that no 
or little supplemental oxygen is being provided. 

When oxygen supply is insufficient, adequate 
ventilation volume is ensured by intake of ambient 
air through the Inlet valve. 

In the presence of high oxygen concentrations 
there is danger from smoking or naked flames. Oil 
or grease must not be used with the resuscitator.
 

Warnings

This Oxygen Kit should only be used by persons 
who have received sufficient training in its use. 
Incorrect operation of the Oxygen Kit can be 
hazardous. 

Do not use the Oxygen Kit if you have any reason to 
be concerned about its functionality.

846131

          

150 ml tidal volume

     

       @ 25 breaths /minute 

         

without          with            without           with

       [l/min]          

       

       

 

 

         

 

 

Regulatory

          2460  

User Guide

  

  

 

20-08251 Rev B

User Guide

Upright

OXYGEN KIT (COMPLETE)

REUSABLE

Intended Use

Laerdal Upright Resuscitator (”Upright”) is a 
self-inflating, manual, reusable resuscitator intended 
for newborns and infants up to 10 kg body mass who 
require respiratory support. 

Upright can provide supplemental oxygen only when 
used with the accessory Oxygen Kit. 

The Oxygen Kit may be reused provided reprocessing 
procedures (page 2) are followed between each 
patient use. The kit (except for the Oxygen Reservoir 
and the Oxygen Tube) must be cleaned and 
disinfected before first use.

Using the Oxygen Kit 

Assembly and disassembly of the Oxygen Kit is 
illustrated on page 2. 

Upright’s pressure release valve can be operated as 
normal when the Oxygen Kit is attached. 

If any components are loose, then tighten or 
reassemble the device and test in accordance with 
page 2. 

Delivered Oxygen Concentration

Measured under room temperature conditions: 

REF Cat. no. 8561733 QTY 1 each

Oxygen

flow

20 ml tidal volume 

@ 60 breaths/minute

reservoir

reservoir

reservoir

reservoir

2               40%            46%           52%           71%

    52%           67% 

63% 

     92%

    58%           89% 

73% 

     96%

Cat. no

Description

Oxygen Reservoir Bag and Tubing

Spare parts

Important Product Information

This product is in compliance with the essential 
requirements of Council Directive 93/42/EEC as 
ammended by Council Directive 2007/47/EC. 

Technical Information

Meets ISO 10651-4:2002/EN ISO 10651-4:2009, 
Lung ventilators – Particular requirements for 
operator–powered resuscitators. 

-18 °C to 50 °C

-40 °C to 60 °C

Operating temperature

Storage temperature

External dimensions of 
Upright when using the
Upright Oxygen kit

(with Newborn Mask size 1,
excluding tube)

 

Approximately
72mm x 375mm x
284mm 

Approximately
288 grams

Mass of Upright with
Oxygen kit

Hard plastic components: Polysulfone (PSU)
Soft plastic components: Silicone rubber
Oxygen Reservoir and Tubing: Polyvinyl chlorine (PVC)
Oxygen Reservoir Bag’s Connector: Polycarbonate (PC)
Not made with natural rubber latex. 

Materials

Manufacturer Information

Global Warranty: See www.laerdal.com

Manufactured in China for:
Laerdal Medical AS, Tanke Svilandsgate 30
P.O. Box 377, 4002 Stavanger, Norway
Tel : +47 51 51 17 00
Fax: +47 51 52 35 57
Email: [email protected]

Pending US and international design registration.
Laerdal® is a trademark or registered trademark
of Laerdal Medical AS.

© 2017  Laerdal Medical AS, All rights reserved.

Page 1

All manuals and user guides at all-guides.com

all-guides.com

Отзывы: