Страница 2: ...or installation 5 2 2 1 Ventilation of the room 5 2 2 2 Location of the appliance in the room 6 2 3 Installation of the appliance 6 2 3 1 Floor 6 2 3 2 Safety distances 6 2 3 3 Checks before lighting for the first time 6 2 3 4 Instructions for moving the stove 6 2 3 5 Height adjustment and levelling the appliance 7 2 3 6 Connection to the flue 7 2 3 6 1 Connecting to the top 7 2 3 6 2 Connecting t...

Страница 3: ... 19 4 1 Maintenance of the appliance 19 4 1 1 Firebox 19 4 1 2 Inside the appliance 19 4 1 3 Flue socket 19 4 1 4 Painted sheet steel cast iron parts 19 4 1 5 Firebox glass 19 4 1 6 Air intake registers 19 4 2 Maintenance of the chimney flue 19 4 3 Important advice 19 TROUBLESHOOTING 20 BASIC BREAKDOWNS 21 DECLARATION OF PERFORMANCE 23 CE MARK 25 ...

Страница 4: ...s set out in the legislation applicable in each country and this instruction book 1 1 General characteristics Unit Tarbes Nominal Heat Output N H O to atmosphere kW 9 Efficiency at N H O 79 CO emission at 13 O2 at N H O 0 07 Gas mass flow at N H O g s 7 8 Gas temperature of flue at N H O ºC 285 Gas temperature on the flue socket flange ºC 342 Optimum flue draught Pa 12 Wood consumption beech at N ...

Страница 5: ... of the fuel fuel loads fuel load frequencies flue draught and system of installation indicated in this Instruction Book Failure to respect these conditions may lead to problems with the appliance deterioration shorter useful life etc which are not covered by the Lacunza warranty Figure No 1 Dimensions of the Tarbes appliance in mm ...

Страница 6: ...e the suitable renewal of the air in the room in which the appliance is fitted the room must always have at least two permanent grilles or openings to the exterior in order to renew the air one for intake and the other for extraction For the installation of its appliances Lacunza recommends an additional section for these openings One of these two grilles must be situated high up in the room at le...

Страница 7: ... the right hand side 550 From the left hand side 550 From the rear 600 From the front 1400 Bear in mind that it may even be necessary to protect non combustible material in order to prevent breakage deformation etc as a result of overheating if the non combustible material is not designed to withstand high temperatures 2 3 3 Checks before lighting for the first time Make sure that the glass is not...

Страница 8: ...el etc To connect the flue to the socket flange insert the piping inside the flange and seal the joint with fire sealant or fire cement to make it completely airtight The installer must ensure that the pipe connected to the appliance is well secured and there is no chance of it coming free from its housing e g as a result of dilatation due to temperature etc On this appliance the flue socket can b...

Страница 9: ...cover and the top connection collar Assembly of the cover at the top and the connection collar at the rear 1 Assemble the cover 1 and the seal 2 with the materials supplied 3 4 5 2 Fit the connecting collar 9 the seal 12 on the back wall with the attachment materials 6 7 8 3 Replace the vermiculite baffle inside the combustion chamber Figure No 7 Assembly of the cover at the top and the connection...

Страница 10: ...t never be connected to the flue The appliance must always have its own chimney flue never sharing a chimney flue with another appliance 2 4 1 Type of flue The flue must be made of special material designed to resist the products of combustion e g stainless steel enamelled steel etc Non central heating appliances without back boiler require an insulated double sleeve flue only on those sections th...

Страница 11: ...t rest on the appliance Bear in mind that high temperatures may be reached in the flue meaning that it is essential that insulation be enhanced in sections in which combustible material is present wooden beams furniture etc It may even be necessary to protect non combustible material in order to prevent breakage deformation etc as a result of overheating if the material is not designed to withstan...

Страница 12: ...ius of the chimney outlet by more than 1m Figure No 10 Distances between the chimney crown and objects within a 10m radius The chimney crown must clear any neighbouring building or obstacle located within a radius of 10m to 20m from the chimney outlet Figure No 11 Distances between the chimney crown and objects within a radius of between 10 and 20m ...

Страница 13: ...ely chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech Other fuels Oak chestnut ash maple birch elm etc Pine and eucalyptus logs are low density and produce very long flames and may cause the parts of the appliance to wear out more quickly than normal Resinous wood may mean that the appliance and the flue need to be cleaned more often Non permitted fuels All ...

Страница 14: ...take regulation o B1 open move towards the right Primary air intake open when lighting the stove Secondary air intake open glass wash Post combustion air intake open o B2 Primary air intake close Secondary air intake semi open glass wash Post combustion air intake open o B2 close move towards the left Primary air intake close Secondary air intake close Post combustion air intake semi open ...

Страница 15: ...er around the appliance this is produced by the condensation of the moisture in the wood on lighting the fire This condensation will no longer appear when the appliance has been lit three or four times and has adapted to its flue If it does not disappear then check the flue draught length and diameter of the flue flue insulation airtightness and the humidity of the wood used 3 4 Safety Do not stor...

Страница 16: ... air inlet and then the secondary air inlet is closed If the air slide is completely closed in position B3 a small air vent remains open to allow for post combustion under the baffle plate IMPORTANT The appliance is exposed to extreme changes in temperature and may as a result make noises when in operation These noises are a natural result of expansion contraction of the parts which make up the ap...

Страница 17: ... the extraction process in reverse order Clean the ashes from the primary register area This area will require regular cleaning to ensure an adequate air flow and a correct movement of the primary register To access this area follow the sequence below for removing pieces 1 Using the glove supplied remove the ash pan and empty it 2 Remove the ash pan support 3 Disassembly the fire box see section 3...

Страница 18: ...ar inner plate 4 Centre rear inner plate 5 Right rear inner plate 6 Left hand inner plate 7 Right hand inner plate 8 Fire box grill left right 9 Fire basket 10 Ash pan 11 Ash pan support 3 8 2 Remove the inner vermiculite plates and the baffle plate in this order a Remove the fire basket 9 b Lift slightly the left deflector 1 like in the figure c Remove the inner plate 6 ...

Страница 19: ...USE 18 3 d Lift the right deflector slightly like in the figure e Remove the right hand inner plate 7 f Remove the inner plates 3 4 and 5 raising previously the deflectors on its back g Remove the 2 deflectors 1 and 2 ...

Страница 20: ...open to keep the door glass cleaner for longer However the glass may get dirty the longer the appliance is used Special degreasing products designed for the purpose should be used to clean it Clean when the glass is cold and taking care not to apply the glass cleaner directly onto the glass as it could come into contact with the door seal cord and damage it 4 1 6 Air intake registers In the air in...

Страница 21: ... continually burn chips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Controlled Mechanical Ventilation leave an outdoor window ajar until the fire is fully alight Too little wood loaded Load as recommended Loads notably smaller than those recommended lead to low smoke temper...

Страница 22: ...BASIC BREAKDOWNS 21 6 BASIC BREAKDOWNS ...

Страница 23: ...BASIC BREAKDOWNS 22 6 ...

Страница 24: ...DECLARATION OF PERFORMANCE 23 7 DECLARATION OF PERFORMANCE ...

Страница 25: ...DECLARATION OF PERFORMANCE 24 7 ...

Страница 26: ...CE MARK 25 8 CE MARK ...

Страница 27: ......

Страница 28: ...LACUNZA KALOR GROUP S A L Pol Ind Ibarrea s n 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 0 ...

Отзывы: