INSTRUCTIONS FOR THE INSTALLER 

11 

 

 

2.  

2.4.

 

Chimney flue 

The  chimney  flue  must  comply  with 

present  standards  on  the  installation  of 
chimneys. 

In  rooms  equipped  with  Controlled 

Mechanical  Ventilation,  the  ventilation 
outlet  must  never  be  connected  to  the 
flue. 

The appliance must always have its own 

chimney flue, never sharing a chimney flue 
with another appliance. 

2.4.1.

 

Type of flue 

The  flue  must  be  made  of  special 

material designed to resist the products of 
combustion (e.g. stainless steel, enamelled 
steel, etc.). 

Non-central-heating 

appliances 

(without  back  boiler)  require  an  insulated, 
double-sleeve  flue  only  on  those  sections 
that  run  outdoors  or  through  cold  areas. 
Single  piping  can  be  used  inside  the 
building,  the  heat  of  the  gases  serving  to 
heat  rooms,  insulating  only  those  sections 
where  excess  temperature  may  cause 
damage.  

If the chimney is constructed, then it  is 

necessary to pipe and insulate it to ensure 
correct updraught. 

The  diameter  of  the  pipe  must  be  the 

same as the diameter of the flue socket on 
the appliance over its entire length in order 
to ensure correct operation. 

The  flue  must  prevent  the  entry  of 

rainwater. 

The flue must be clean and airtight over 

its entire length. 

The flue must be at least 6m tall and the 

chimney  cap  must  not  hinder  the  free 
release of gases.  

If  the  flue  tends  to  suffer  from 

downdraught, then it is necessary to fit an 
effective  anti-downdraught  cowl,  a  static 

cowl or a smoke extraction fan, or reshape 
the chimney.  

Never make 90º bends, due to the great 

loss of draught they cause, and reduce 45º 
bends down to an absolute minimum. Each 
45º bend is equivalent to a 0.5m reduction 
in  flue  length.  Horizontal  flue  sections 
should  not  be  installed  because  they  cut 
updraught a great deal. 

If the flue draws at more than 20 Pa on 

12Pa appliances, then an effective damper 
must be fitted on the flueway. This damper 
must be visible and accessible. 

The  chimney  flue  must  not  rest  on  the 

appliance. 

Bear  in  mind  that  high  temperatures 

may be reached in the flue, meaning that it 
is  essential  that  insulation  be  enhanced  in 
sections  in  which  combustible  material  is 
present (wooden beams, furniture, etc.). It 
may  even  be  necessary  to  protect  non-
combustible  material  in  order  to  prevent 
breakage,  deformation,  etc.,  as  a  result  of 
overheating if the material is not designed 
to withstand high temperatures.  

It  must  be  possible  to  clean  the  entire 

flue, no sections being left inaccessible for 
cleaning purposes. 

2.4.2.

 

Chimney crown 

The  upper  end  of  the  chimney  must 

clear  the  roof,  the  roof  ridge  or  any 
obstacle located on the roof by at least 1m. 

 

Содержание Nickel 1000 DC

Страница 1: ...Nickel 800 DC Nickel 1000 DC Instruction Book ...

Страница 2: ...ing to installers 6 2 2 Room for installation 6 2 2 1 Ventilation of the room 6 2 2 2 Location of the appliance in the room 7 2 3 Installation of the appliance 7 2 3 1 Floor 7 2 3 2 Safety distances 7 2 3 3 Checks before lighting for the first time 7 2 3 4 Height adjustment and levelling the appliance 8 2 3 5 Casing 8 2 3 6 Connection to the flue 9 2 3 7 Piping air to the firebox 10 2 3 8 Exterior...

Страница 3: ...8 4 1 3 Flue socket 18 4 1 4 Painted sheet steel cast iron parts 18 4 1 5 Firebox glass 18 4 1 6 Air intake registers 18 4 2 Maintenance of the chimney flue 18 4 3 Important advice 18 TROUBLESHOOTING 19 BASIC BREAKDOWNS 20 DECLARATION OF PERFORMANCE 21 CE MARK 23 ...

Страница 4: ...ch country and this instruction book 1 1 General characteristics Unit Nickel 800 DC Nickel 1000 DC Nominal Heat Output N H O to atmosphere kW 15 16 Efficiency at N H O 80 75 CO emission at 13 O2 at N H O 0 15 0 16 Gas mass flow at N H O g s 14 5 14 7 Gas temperature of flue at N H O ºC 240 260 Gas temperature on the flue socket flange ºC Optimum flue draught Pa 12 12 Wood consumption beech at N H ...

Страница 5: ...the fuel fuel loads fuel load frequencies flue draught and system of installation indicated in this Instruction Book Failure to respect these conditions may lead to problems with the appliance deterioration shorter useful life etc which are not covered by the Lacunza warranty Figure No 1 Dimensions of the Nickel 800 DC appliance in mm ...

Страница 6: ...PRESENTATION OF THE APPLIANCE 5 1 Figure No 2 Dimensions of the Nickel 1000 DC appliance in mm ...

Страница 7: ... the suitable renewal of the air in the room in which the appliance is fitted the room must always have at least two permanent grilles or openings to the exterior in order to renew the air one for intake and the other for extraction For the installation of its appliances Lacunza recommends an additional section for these openings One of these two grilles must be situated high up in the room at les...

Страница 8: ... combustible material 2 3 2 Safety distances Be sure to respect the appliance installation distances from combustible materials Looking at the appliance head on Distance to combustible materials mm From the right hand side 100 mm of isolation From the left hand side 100 mm of isolation From the rear 1500 From the front 1500 Bear in mind that it may even be necessary to protect non combustible mate...

Страница 9: ...its height The legs can be adjusted using a 24mm spanner 2 3 5 Casing Make sure that the material around the appliance is not flammable or likely to deteriorate as a result of heat wallpaper carpet plastic based casing Silestone etc The image below gives an example of how the appliance can be encased properly Figure No 6 Interior diagram of the casing Key to casing diagram 1 Ceiling 2 Flue 3 Incom...

Страница 10: ...sure should have a free opening of at least 100 cm2 for the intake of air for combustion Warning on appliances on which it is possible to pipe air to the firebox the hood requires a further air inlet at the bottom in addition to the 1 000cm2 inlet if the air supply comes from the room in which the appliance is fitted On non central heating appliances without back boiler Lacunza does not recommend ...

Страница 11: ...1 meter for each accessory used This is the best option because it means that draughts are not created in and oxygen is not consumed from the room in which the appliance is fitted A further advantage is that there is no danger of downdraught which may hinder the correct updraught of the appliance when an extractor or mechanical ventilation appliance is used in the same room as the central heating ...

Страница 12: ... length The flue must be at least 6m tall and the chimney cap must not hinder the free release of gases If the flue tends to suffer from downdraught then it is necessary to fit an effective anti downdraught cowl a static cowl or a smoke extraction fan or reshape the chimney Never make 90º bends due to the great loss of draught they cause and reduce 45º bends down to an absolute minimum Each 45º be...

Страница 13: ...tacle located within a 10m radius of the chimney outlet by more than 1m Figure No 12 Distances between the chimney crown and objects within a 10m radius The chimney crown must clear any neighbouring building or obstacle located within a radius of 10m to 20m from the chimney outlet Figure No 13 Distances between the chimney crown and objects within a radius of between 10 and 20m ...

Страница 14: ...ely chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech Other fuels Oak chestnut ash maple birch elm etc Pine and eucalyptus logs are low density and produce very long flames and may cause the parts of the appliance to wear out more quickly than normal Resinous wood may mean that the appliance and the flue need to be cleaned more often Non permitted fuels All ...

Страница 15: ...TIONS OF USE 14 3 3 2 Description of the parts of the appliance 3 2 1 Operating components Figure No 15 Operating components on the appliance A Firebox door handle B Air intake o B1 closed left o B2 open right ...

Страница 16: ...pliance has been lit three or four times and has adapted to its flue If it does not disappear then check the flue draught length and diameter of the flue flue insulation airtightness and the humidity of the wood used 3 4 Loading fuel In order to load firewood open the firebox door gently preventing the sudden entry of air to the firebox so that smoke does not enter the room that the appliance is i...

Страница 17: ...mend you the air Intake 50 open 3 6 Removing ash Following sustained use of the appliance it is necessary to remove the ash from the firebox Remove the ashpit box when cold or using something to prevent yourself from getting burned glove Never throw hot embers into the rubbish Access the ashpit by opening the door on the appliance 3 7 Deflectors The appliance has 1 vermiculite deflector and 2 stai...

Страница 18: ...gure No 19 Remove the four refractories from the right side Figure No 20 Turn the right side refractory as in the picture so that the deflector can fall Figure No 21 Drop the refractory holding it Figure No 22 Remove de deflector ...

Страница 19: ...r glass cleaner for longer However the glass may get dirty the longer the appliance is used Special degreasing products designed for the purpose should be used to clean it Clean when the glass is cold and taking care not to apply the glass cleaner directly onto the glass as it could come into contact with the door seal cord and damage it 4 1 6 Air intake registers In the air intake for combustion ...

Страница 20: ... continually burn chips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Controlled Mechanical Ventilation leave an outdoor window ajar until the fire is fully alight Too little wood loaded Load as recommended Loads notably smaller than those recommended lead to low smoke temper...

Страница 21: ...040000904 Nickel Adour Parrilla hogar 1 6 5044700002 Nickel Manilla puerta hogar 2 7 Cordón plano pelos 8x2mm 2 5 m 8 509020000042 Cordón Negro Ø13mm 2 5 m 9 5044700003 Nickel DC Vermiculita Lateral 340x340x40 mm 2 10 5044800006 Nickel 800 DC Vermiculita Base lateral 244x210x30 mm 4 5015300006 Nickel 1000 DC Vermiculita Base Lateral 344x210x30 4 11 5044700006 Nickel DC Vermiculita Base central 220...

Страница 22: ...DECLARATION OF PERFORMANCE 21 7 DECLARATION OF PERFORMANCE ...

Страница 23: ...DECLARATION OF PERFORMANCE 22 7 ...

Страница 24: ...CE MARK 23 8 CE MARK ...

Страница 25: ...CE MARK 24 8 ...

Страница 26: ......

Страница 27: ......

Страница 28: ...LACUNZA KALOR GROUP S A L Pol Ind Ibarrea s n 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 0 ...

Отзывы: