INSTRUCTIONS FOR THE INSTALLER 

 

 

2.  

On 

non-central-heating 

appliances 

(without  back  boiler),  Lacunza  does  not 
recommend  enveloping  the  outside  of 
appliances with insulation. 

¡Warning!

:    The  installer  must  fit  the 

necessary  inspection  accesses  (trap  doors, 
hatches, etc.) so that everything inside the 
hood that may need maintenance work or 
replacement  can  be  accessed  at  any  time, 
e.g.  counterweight  system,  hydraulic 
components, 

heating 

circuit 

safety 

components. 

2.3.6.

 

Connection to the flue 

The appliance must be connected to the 

chimney flue  using special piping designed 
to  resist  the  products  of  combustion  (e.g. 
stainless steel, enamelled steel, etc.). 

To connect the flue to the socket flange, 

insert the piping inside the flange and seal 
the joint with fire sealant or fire cement to 
make it completely airtight. 

The  installer must  ensure  that  the  pipe 

connected to the appliance is well secured 
and  there  is  no  chance  of  it  coming  free 
from  its  housing  (e.g.  as  a  result  of 
dilatation due to temperature, etc.). 

2.3.7.

 

Piping air to other rooms 

It  is  possible  to  pipe  some  of  the  heat 

generated  to  other  rooms  in  the  house 
using  the  appliance.  This  does  not  mean 
that  the  appliance  works  more  efficiently, 
but it does mean that the heat it creates is 
distributed better. For this purpose,  in the 
top  surface  of  the  appliance  there  are  4 
potential  hot-air  outlets  with  diameters  of 
120mm  on  the  top  shell  of  the  appliance. 
Pipes  can  be  fitted  from  these  outlets  to 
other rooms. If you intend to do this, bear 
the following points in mind. 

 

Do  not  break  the  scored  steel 

circles completely. Simply bend them in 
order  to  facilitate  the  conduction  of 
heat to the pipe. 

 

The  air  ducts  must  always  be  heat 

insulated  and  smooth  inside  (not 
corrugated). 

 

The  pipes  must  always  have  an 

upward slant to facilitate movement by 
air density. 

 

On routes with a lot of load loss (a 

lot  of  retention),  air  movement  can  be 
forced along the ducts using a motor or 
fan,  provided  that  it  is  designed  to 
withstand such temperature conditions. 

Bear  in  mind  that  air  ducts  mean  that 

noise travels more easily from one room to 
another. 

The  following  table  shows  the  heat 

output  of  the  air  from  the  hot-air  outlets 
with  the  appliance  working  at  Nominal 
Heat Output: 

 

 

Output 

(kW) 

 

 

 

 

Figure No.6 -

 

Table showing heat output of the 

air leaving the appliance 

Note:

  The  values  shown  in  the  above 

table  were  measured  at  the  appliance 
output point and based on tests performed 
at  nominal  heat  output  and  maximum  fan 
speed. 

All hot-air ducts lose heat, meaning that 

the  heat  output  obtained  at  the  end  of 
piping always depends on its design. 

 

 

Содержание INCA100

Страница 1: ...Inca 80 100 C V Instruction Book ...

Страница 2: ...lation 6 2 2 1 Ventilation of the room 6 2 2 2 Location of the appliance in the room 7 2 3 Installation of the appliance 7 2 3 1 Floor 7 2 3 2 Safety distances 7 2 3 3 Checks before lighting for the first time 7 2 3 4 Height adjustment and levelling the appliance 7 2 3 5 Casing 7 2 3 6 Connection to the flue 9 2 3 7 Piping air to other rooms 9 2 3 8 Piping air to the firebox 10 2 3 8 1 Combustion ...

Страница 3: ...ADVICE 21 4 1 Maintenance of the appliance 21 4 1 1 Firebox 21 4 1 2 Inside the appliance 21 4 1 3 Flue socket 21 4 1 4 Enamelled steel parts 21 4 1 5 Firebox glass 21 4 2 Maintenance of the chimney flue 21 4 3 Important advice 21 TROUBLESHOOTING 22 BASIC BREAKDOWNS 23 DECLARATION OF PERFORMANCE 25 CE MARK 29 ...

Страница 4: ... 0 07 0 07 0 07 Gas mass flow at N H O g s 10 6 10 6 14 2 14 2 Gas temperature downstream of flue socket at N H O ºC 281 281 270 270 Optimum flue draught Pa 12 12 12 12 Wood consumption beech at N H O Kg h 4 23 4 23 4 7 4 7 Dimensions of the firebox Width mm 640 640 840 840 Depth mm 360 360 360 360 Useful height mm 525 525 525 525 Dimensions of the logs cm 60 60 80 80 Volume heated 45w m at N H O ...

Страница 5: ...PRESENTATION OF THE APPLIANCE 4 1 with the appliance deterioration shorter useful life etc which are not covered by the Lacunza warranty Figure No 1 Dimensions of the INCA 80 appliance in mm ...

Страница 6: ...PRESENTATION OF THE APPLIANCE 5 1 Figure No 2 Dimensions of the INCA 100 appliance in mm ...

Страница 7: ... the suitable renewal of the air in the room in which the appliance is fitted the room must always have at least two permanent grilles or openings to the exterior in order to renew the air one for intake and the other for extraction For the installation of its appliances Lacunza recommends an additional section for these openings One of these two grilles must be situated high up in the room at les...

Страница 8: ... protect non combustible material in order to prevent breakage deformation etc as a result of overheating if the non combustible material is not designed to withstand high temperatures 2 3 3 Checks before lighting for the first time Make sure that the glass is not broken or damaged Make sure that the flueway is not obstructed with packing or loose parts Make sure that the airtight joints on the fl...

Страница 9: ...ove it just before the insulating deflector inside the casing These inlet and outlet sections must ensure air renewal in such a way as to avoid damage to parts inside the hood due to excess temperature This specification must be observed regardless of the type of installation chosen with or without forced ventilation combustion air from indoors or outdoors directed hot air outlets with or without ...

Страница 10: ...ly but it does mean that the heat it creates is distributed better For this purpose in the top surface of the appliance there are 4 potential hot air outlets with diameters of 120mm on the top shell of the appliance Pipes can be fitted from these outlets to other rooms If you intend to do this bear the following points in mind Do not break the scored steel circles completely Simply bend them in or...

Страница 11: ...put by natural convection or by forced convection involving a fan to ensure that ITACA INCA appliances work properly There now follows a description and image of each of these options Key to combustion air intake and hot air output installation option diagrams 1 Hot air output grille 2 Combustion air intake grille 3 piping 4 Combustion air intake nozzle 5 Combustion air intake from outdoors OPTION...

Страница 12: ...vious option but also involves leading the hot air output from the nozzles on top to the hot air output grilles or to other adjoining rooms via piping with a diameter of 120mm The nozzles on top of the appliance not to be used should be capped Figure No 10 Image showing Option D WARNING When the appliance has a fan C V option it is important that the shell is well ventilated through both the upper...

Страница 13: ...ge the enamel Then pull it forwards Perform the removal process in reverse order to refit the frame 2 3 10 Fan potentiometer connection only for models C V ITACA INCA c v models the models with fans are prepared for connection on the potentiometer supplied The appliance has 2 hoses protruding from it PROBE hose 2 wires Fan hose VENT 3 wires The two hoses are connected to the potentiometer accordin...

Страница 14: ...ey is constructed then it is necessary to pipe and insulate it to ensure correct updraught The diameter of the pipe must be the same as the diameter of the flue socket on the appliance over its entire length in order to ensure correct operation The flue must prevent the entry of rainwater The flue must be clean and airtight over its entire length The flue must be at least 6m tall and the chimney c...

Страница 15: ...between chimney crown and roof ridge The chimney crown must clear the highest point of any neighbouring building or obstacle located within a 10m radius of the chimney outlet by more than 1m Figure No 14 Distances between the chimney crown and objects within a 10m radius The chimney crown must clear any neighbouring building or obstacle located within a radius of 10m to 20m from the chimney outlet...

Страница 16: ...ely chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech Other fuels Oak chestnut ash maple birch elm etc Pine and eucalyptus logs are low density and produce very long flames and may cause the parts of the appliance to wear out more quickly than normal Resinous wood may mean that the appliance and the flue need to be cleaned more often Non permitted fuels All ...

Страница 17: ...rm weather warm days early hours of the afternoon on sunny days may lead to lighting and updraught problems Certain weather conditions such as fog ice humidity entering the flue etc may hinder sufficient updraught in the flue and lead to suffocation Proceed as follows in order to light the appliance satisfactorily Open the firebox door and open all the firebox air intake inlets to the full Place p...

Страница 18: ...nominal amount see table in section 1 1 For minimum burning e g at night use thicker logs When the firebox is loaded close the door Be careful when placing logs in the firebox on appliances with vermiculite interiors Vermiculite is a fragile material and may crack if knocked 3 5 Operation The appliance should be operated with the door closed For safety reasons never close all the appliance s combu...

Страница 19: ... socket This can be used to modify the section through which the gases pass and consequently control the updraught The appliance has 1 2 deflector s The upper one is fixed whilst the middle and lower ones can be dismantled the lower one has 4 positions in order to adapt it better to the flue draught provided there is minimum updraught Position 1 more closed greater resistance to smoke evacuation g...

Страница 20: ...ca C V models have a fan for the forced convection of the hot air generated around the appliance inside the shell This air can be piped to other rooms IMPORTANT This appliance is not covered by our warranty unless directly connected to the mains electricity supply in accordance with the conditions described in the relevant section in 1 1 Inca appliances with the C V option forced ventilation with ...

Страница 21: ...the firebox and the thermostat reaches a temperature of approximately 50ºC the fan starts working at the power set on the potentiometer rotating wheel and stops automatically when the temperature drops beneath 50ºC Manual mode The fan works at the speed set using the rotating wheel independently of the thermostat i e the fan can be started up before the thermostat reaches 50ºC Figure No 23 Itaca p...

Страница 22: ... they could damage the enamel 4 1 5 Firebox glass Keep the secondary air intake open to keep the door glass cleaner for longer However the glass may get dirty the longer the appliance is used Special degreasing products designed for the purpose should be used to clean it Clean when the glass is cold and taking care not to apply the glass cleaner directly onto the glass as it could come into contac...

Страница 23: ...hips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Controlled Mechanical Ventilation leave an outdoor window ajar until the fire is fully alight Too little wood loaded Load as recommended Loads notably smaller than those recommended lead to low smoke temperature and downdraug...

Страница 24: ...BASIC BREAKDOWNS 23 6 BASIC BREAKDOWNS ...

Страница 25: ...BASIC BREAKDOWNS 24 6 ...

Страница 26: ...DECLARATION OF PERFORMANCE 25 7 DECLARATION OF PERFORMANCE ...

Страница 27: ...DECLARATION OF PERFORMANCE 26 7 ...

Страница 28: ...DECLARATION OF PERFORMANCE 27 7 ...

Страница 29: ...DECLARATION OF PERFORMANCE 28 7 ...

Страница 30: ...CE MARK 29 8 CE MARK ...

Страница 31: ...CE MARK 30 8 ...

Страница 32: ......

Страница 33: ...LACUNZA KALOR GROUP S A L Pol Ind Ibarrea s n 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 02 ...

Отзывы: