INSTRUCTIONS FOR THE INSTALLER
10
2.
the appliance over its entire length in order
to ensure correct operation.
The flue must prevent the entry of
rainwater.
The flue must be clean and airtight over
its entire length.
The flue must be at least 6m tall and the
chimney cap must not hinder the free
release of gases.
If the flue tends to suffer from
downdraught, then it is necessary to fit an
effective anti-downdraught cowl, a static
cowl or a smoke extraction fan, or reshape
the chimney.
Never make 90º bends, except the one
on kitchen-stove outlets, due to the great
loss of draught they cause, and reduce 45º
bends down to an absolute minimum. Each
45º bend is equivalent to a 0.5m reduction
in flue length. Horizontal flue sections
should not be installed because they cut
updraught a great deal.
If the flue draws at more than 20 Pa on
12Pa appliances and more than 25Pa on
17Pa appliances, then an effective damper
must be fitted on the flueway. This damper
must be visible and accessible.
The chimney flue must not rest on the
appliance.
Bear in mind that high temperatures
may be reached in the flue, meaning that it
is essential that insulation be enhanced in
sections in which combustible material is
present (wooden beams, furniture, etc.). It
may even be necessary to protect non-
combustible material in order to prevent
breakage, deformation, etc., as a result of
overheating if the material is not designed
to withstand high temperatures.
It must be possible to clean the entire
flue, no sections being left inaccessible for
cleaning purposes.
2.4.2.
Chimney crown
The upper end of the chimney must
clear the roof, the roof ridge or any
obstacle located on the roof by at least 1m.
Figure No.8 -
Distances between chimney
crown and roof ridge
Содержание Clasica 5T
Страница 1: ...Clásica 5T Clásica 7T Clásica 8T Instruction Book ...
Страница 6: ...PRESENTATION OF THE APPLIANCE 5 1 Figure No 2 Dimensions of the Clásica 7T appliance in mm ...
Страница 7: ...PRESENTATION OF THE APPLIANCE 6 1 Clas ica Figure No 3 Dimensions of the Clásica 8T appliance in mm ...
Страница 23: ...BASIC BREAKDOWNS 22 6 BASIC BREAKDOWNS Figure No 19 Basic breakdowns ...
Страница 25: ...DECLARATION OF PERFORMANCE 24 7 DECLARATION OF PERFORMANCE ...
Страница 26: ...DECLARATION OF PERFORMANCE 25 7 ...
Страница 27: ...DECLARATION OF PERFORMANCE 26 7 ...
Страница 28: ...DECLARATION OF PERFORMANCE 27 7 ...
Страница 29: ...DECLARATION OF PERFORMANCE 28 7 ...
Страница 30: ...DECLARATION OF PERFORMANCE 29 7 ...
Страница 31: ...CE MARK 30 8 CE MARK ...
Страница 32: ...CE MARK 31 8 ...
Страница 33: ...CE MARK 32 8 ...
Страница 34: ...CE MARK 33 8 ...
Страница 35: ...CE MARK 34 8 ...