background image

Updated: 06/01/2021 

   

 

 
 
 
 

MILLENIUM / SMART MILLENIUM 

USER MANUAL 

 
 

 

 

 

Содержание MILLENIUM

Страница 1: ...Updated 06 01 2021 MILLENIUM SMART MILLENIUM USER MANUAL ...

Страница 2: ...nt crossing Function 17 8 CYCLE IN PROGRESS 17 9 PARAMETERS MENU 18 A Language 18 B Remote Control Settings 18 C PTL Settings 18 D Information 18 E Maintenance 18 F Reset 18 10 SMART MILLENIUM MENU 19 11 PTL SHUTDOWN STANDBY 19 12 REMOTE CONTROL 20 A Activation 20 B Standby 20 C Remote Control SCREEN 20 D Switch Off Remote Control 20 E Audible Alarms 20 F Power Supply 21 G Adding a Remote Control ...

Страница 3: ...e ambient light humidity temperature and the programming mode used As measurement technology and instruments are constantly evolving this information is provided for general reference only If the battery level is low alerts are reported to the remote control allowing the user to replace it before the lights go out Battery 24 hrs Battery 12 hrs Battery 1 hr When there is less than 24 hours battery ...

Страница 4: ...IMER 13 STORAGE SPACE FOR REMOTE CONTROL NO 1 4 GREEN LENS 14 UPPER EXTENSION LOCKING HANDLE 5 UPPER EXTENSION 15 LOWER EXTENSION LOCKING HANDLE 6 LOWER EXTENSION 16 RETRACTABLE LIFTING ARMS 7 TIGHTENING LEVER 17 PUNCTURE PROOF REAR WHEELS 8 CHASSIS 9 BATTERY COVER 10 PUNCTURE PROOF FRONT WHEEL 1 5 15 8 10 9 7 4 3 2 11 14 16 17 13 12 6 ...

Страница 5: ... PASS THROUGH FOR LIGHT 3 ANTI THEFT BAR PASS THROUGH BAR OPTIONAL 4 PADLOCK PASS THROUGH PADLOCK OPTIONAL 5 POWER CABLE PASS THROUGH 6 TRAFFIC LIGHT STACKING PASS THROUGH 7 GROUND ANCHORING PASS THROUGH FOR LIGHT 8 230 V POWER CABLE PASS THROUGH FOR BATTERY CHARGING 9 LIGHT HEAD GUARD 5 1 2 7 4 3 8 9 6 ...

Страница 6: ...se the locking bolt 3 Fold or unfold the extension 4 Tighten the handle Perform this step on both handles D LOCKING UNLOCKING THE HEAD FOLDING SYSTEM Once the extensions have been deployed lock the tightening lever to ensure optimum stability for the light head and extensions Note before folding the light head over the box ensure that the tightening lever is in the unlocked position ...

Страница 7: ...system reset A QUICK START OK QUICK START SELECT COUNTRY FRANCE SELECT LANGUAGE FRENCH FINISHED OK OK Position the remote control opposite the infrared signal window located on the back of the light head Select the QUICK START menu from the remote control As the choice of country affects the programming mode of your traffic lights please ensure you comply with the country where it is used DUE TO S...

Страница 8: ...ntrols Lights are paired using infrared the infrared signal window is located on the back of each light head The remote control should be positioned a few centimetres away and opposite the infrared signal window During pairing the ID of each light is indicated on the central lens for simplified deployment ENSURE THAT THE LIGHTS TO BE PAIRED ARE POWERED BEFORE BEGINNING THE PAIRING PHASE IF THE REM...

Страница 9: ... PTL A OK SCAN PTL B OK PTL B OK OK OK OK NEXT PTL OK PAIRING 2 PTLs OK PAIRING SCAN PTL A OK PTL A OK SCAN PTL B OK PTL B OK OK OK OK FINISHED OK SCAN PTL C OK PTL C OK OK OK FINISHED OK PAIRING FINISHED OK Available choices FINISH OR NEXT PTL Next PTL when there are 4 PTL to pair PAIRING FINISHED OK Position the remote control opposite the infrared signal window located on the back of the light ...

Страница 10: ... PAIRING chapter for more information 7 PROGRAMMING THE PTLs Once the PTLs have been PAIRED the PROGRAMMING menu appears This menu gives you a choice of 7 programmable modes for your PTLs The following modes are available on MILLENIUM STANDARD MODE STANDARD WORKSITE EXIT MODE 3 paired PTLs minimum MANUAL ALTERNATING MODE 2 paired PTLs maximum FLASHING YELLOW MODE MANUAL MODE SMART MILLENIUM Traffi...

Страница 11: ...000 SELECT DISTANCE 100m PROGRAMME MODE FINISHED OK OK Available choices 2 000 2 to 5 000 5 to 8 000 8 to 11 000 Available choices 20 m to 2000 m 3 OR 4 PTL SYSTEM Available choices 2 000 2 to 5 000 5 to 8 000 8 to 11 000 Available choices 20 m to 2000 m JUNCTION TYPE CROSSED NR VEHIC DAY LESS THAN 2 000 SELECT DISTANCE 100m PROGRAMME MODE FINISHED OK OK OK Available choices Crossed Rotating ...

Страница 12: ...ight Light B or B D Varies based on the number of PTLs paired Available choices Manual or automatic activation Automatic only available on Smart Millenium OK NR PTL TRAFFIC 2 PTL SYNCHRONISED WORKSITE EXITS 1 PTL WORKSITE PTL PTL B PLANT CROSSING MANUAL ACTIV OK OK OK PROGRAMME MODE FINISHED OK 3 TRAFFIC PTLs Available choices 2 000 2 to 5 000 5 to 8 000 8 to 11 000 11 to 14 000 Available choices ...

Страница 13: ...on the central lens mode used when the traffic no longer requires an alternating traffic flow system to be implemented The mode is also automatically activated on all currently operating system lights in the following situations Battery life 12 hrs Battery disconnected from the PTL during use Radio fault if modes Standard Worksite Exit Automatic Regulation Green on Detection are active Red lens fa...

Страница 14: ...NTRAL YELLOW IS REPLACED BY THE DURATION OF THE CENTRAL YELLOW RED REMOTE CONTROL INTERFACE Distance adjustable from 20 to 2 000 m using the UP and DOWN keys Green duration adjustable from 5 to 120 seconds Pressing and holding the UP and DOWN keys allows the user to increase or decrease the time in 10 second increments OK MANUAL MODE CENTRAL YELLOW 5 SECS SELECT DISTANCE 100m GREEN DURATION 20 SEC...

Страница 15: ...stalled Smart Millenium offer motorists reduced waiting time Site workers will also benefit from a better regulated and less stressful worksite VEHICULE ACTUACTED MODE ONLY AVAILABLE IF ALL PAIRED PTLs ARE EQUIPPED WITH REGULATION RADARS AND LOCATED AT A MAXIMUM DISTANCE OF 800 M CYCLES BEGIN AFTER ALL RED ALLOWING THE CENTRAL AREA TO BE FULLY CLEARED REMOTE CONTROL INTERFACE Available choices 2 0...

Страница 16: ...ic flows are equivalent on the different roads the system regulates traffic by dynamically optimising flows GREEN ON DETECTION MODE ONLY AVAILABLE IF ALL PAIRED PTLs ARE EQUIPPED WITH REGULATION RADARS AND LOCATED AT A MAXIMUM DISTANCE OF 800 M CYCLES BEGIN AFTER ALL RED ALLOWING THE CENTRAL AREA TO BE FULLY CLEARED REMOTE CONTROL INTERFACE Available choices 2 000 2 to 5 000 5 to 8 000 8 to 11 000...

Страница 17: ... maximum distance between PTLs 800m Choice of automatic activation is only available in STANDARD WORKSITE EXIT mode Deactivate PLANT CROSSING MILLENIUM 2 possible choices to be defined at the programming stage manually by pressing the STOP button on the remote control for 5 seconds automatically after ALL RED defined based on programming not available if PTLs are synchronised Maximum distance betw...

Страница 18: ...L alarm is reported to the remote control within 30 seconds When a PTL is repositioned the alarm is raised after 35 seconds and the PTLs resume their cycle after All Red RADIO to create a system of PTLs and communicate between the PTLs and the remote RADAR to automatically regulate traffic only available on Smart Millenium Traffic Regulation INTERNAL COUNTDOWN TIMER can be deactivated when an exte...

Страница 19: ...te the SYSTEM SHUTDOWN menu is equivalent to the end of a worksite and thus when shutting down paired PTLs the pairing is removed and will have to be performed again if the same system is redeployed Note as a connected battery will discharge even one that is not used ensure that the battery cables are disconnected after use B PLACE PTLs ON STANDBY Placing the PTLs on standby allows the lenses to b...

Страница 20: ... paired on the remote control Flashing symbol in case of a radio error Symbol informing that an up down choice is possible Remote control charge D SWITCH OFF REMOTE CONTROL To ensure a continuous connection with the current PTL system the remote control cannot be switched off once the PTL system has shut down the remote control enters extended standby mode and stops communicating in order to conse...

Страница 21: ...are reported to the remote control LOSS OF RADIO SIGNAL For losses of radio signal lasting 15 secs or more an alarm is reported to the remote control In order to maintain the current cycle and ensure normal operation the PTLs change based on time if STANDARD or MANUAL modes are in operation If STANDARD WORKSITE EXIT AUTOMATIC REGULATION GREEN ON DETECTION modes are in operation the PTLs switch to ...

Страница 22: ...ORMATION 15 AVAILABLE OPTIONS A FLASHING BEACON The flashing beacon provides information about the status of the red lens by lighting up from the back of the light head when the red lens is lit Hence the flashing beacon helps people working on the site to better analyse vehicle movements and increase safety in the worksite area The flashing beacon option is especially recommended when using MANUAL...

Страница 23: ...AL 12 V MINIMUM 10 2 V MAXIMUM 14 2 V INSTALLATION Clean the battery terminals and connection lugs thoroughly Start by connecting the positive terminal red then the negative terminal black Only an authorised person is permitted to install the battery Please follow the battery manufacturer s instructions REMOVAL After each use disconnect the battery to conserve its charge Start by disconnecting the...

Страница 24: ...G The presence of the WEEE symbol means that this product and or its battery must be disposed of separately from household waste in Europe and Turkey The separate collection and recycling of the product and or its battery help to preserve natural resources and ensure that it is recycled in a way that protects human health and the environment This product must be taken to a collection point designa...