Read this manual before operating the Labtron Digital Blood 

Pressure Monitor. Save this manual for future reference.

707A-INS-LAB-RevC08

Item 707A, 

707A X, 707A C 

Digital Blood Pressure 

Monitor

w

ith Manual Inflation &

 

Automatic Deflation

User Manual

707A-INS-LAB-RevC08-book.indd   1

1/3/08   11:36:34 AM

Содержание 707A

Страница 1: ...2 www grahamfield com 2008 GF Health Products Inc 707A INS LAB RevC08 Read this manual before operating the Labtron Digital Blood Pressure Monitor Save this manual for future reference 707A INS LAB Re...

Страница 2: ...al errors Contents SAFETY GUIDELINES PLEASE READ BEFORE USE 3 INTENDED USE 3 Features 4 Battery installation replacement 5 BLOOD PRESSURE 5 Preparing to measure blood pressure 6 Measuring blood pressu...

Страница 3: ...professional or Graham Field dealer for direction in the use of this product If components are damaged or missing contact your Graham Field dealer immediately DO NOT use substitute parts GF Health Pro...

Страница 4: ...RH Storage transport 14 F 140 F 10 C 60 C 10 95 RH Standard cited EN 1060 1 Noninvasive blood pressure measuring equipment general requirements EN 1060 3 Noninvasive blood pressure measuring equipmen...

Страница 5: ...ment Reference method for clinical trials Auscultatory measurement Weight Approximately 75 lb 340g without batteries Battery installation replacement 1 Slide the battery cover off in the direction of...

Страница 6: ...to 10 minutes before a blood pressure measurement and between blood pressure measurements 3 Refrain from eating smoking and drinking especially alcoholic General troubleshooting Problem Recommended A...

Страница 7: ...fter cuff is correctly positioned seek medical attention immediately Batteries are exhausted Replace with four new AAA alkaline batteries beverages before a measurement 4 Remove any clothing on the up...

Страница 8: ...ance Do not drop or pull excessively on monitor components or subject them to strong impact Do not use monitor close to any device with a strong electrical field such as television microwave oven X Ra...

Страница 9: ...ns or questions about your results always contact your physician Only your physician is qualified to analyze blood pressure Measuring blood pressure Symbol key LCD symbols you may see during measureme...

Страница 10: ...ain calm and still to avoid causing any measurement error 5 The systolic pressure diastolic pressure and pulse will display in the format shown at right The device will completely deflate when measure...