EH/EG Series
–
User Manual
www.labtechsrl.com
Page 1 of 28
EH/EG SERIES
Hotplate
USER MANUAL
Version 202305HP
Страница 1: ...EH EG Series User Manual www labtechsrl com Page 1 of 28 EH EG SERIES Hotplate USER MANUAL Version 202305HP...
Страница 2: ...l safety 8 Fire safety 8 Chemical safety 8 Recommendation 8 Other Information 9 General Information 10 17 EH Series 10 EH20A Plus EH35A EH45A Plus 10 EH20B EH35B EH45B EH45C 11 EH20D 12 EH20S EH35S EH...
Страница 3: ...ure Control for EH20D 21 How to Operate EG20A PLUS EG35A PLUS EG37APLUS 22 Temperature Control for EG20A PLUS EG35A PLUS EG37APLUS 22 How to Operate EG20B EG35B EG37B EG37C 23 Temperature Control for...
Страница 4: ...our local Representative or LabTech at the following address LabTech Srl Via Fatebenefratelli 1 5 24010 Sorisole BG Italy Tel 39 035 576614 Website www labtechsrl com E mail marketing labtechsrl com L...
Страница 5: ...ce Products tested and found compliant with the requirements defined in the EC Council Directive for Electromagnetic Compatibility established by 2014 30 EU as well as Low Voltage Directive LVD 2014 3...
Страница 6: ...ransportation by Seller in either case In an event Buyer discovers or learns that a product does not conform to warranty Buyer shall immediately notify Seller in writing of such non conformity specify...
Страница 7: ...ide Contact us There are several ways to contact LabTech Srl To contact Technical Support Phone 39 035 576614 E mail customer care labtechsrl com To contact Application Department Phone 39 035 576614...
Страница 8: ...capacity of cable must be enough Besides a safe protection ground wire must be allocated otherwise it may cause the electric accident Always turn off the equipment and disconnect the power cord from...
Страница 9: ...nd the equipment if the distance is too short it may cause articles around to be damaged Please put the equipment on a firm strong holder It s better to consult the engineers of our company before per...
Страница 10: ...neral Information EH SERIES EH20A Plus EH35A Plus EH45APLUS The control panel consists of the following keys Graph of Temperature Control for EH20A Plus EH35A Plus EH45APLUS Heating Board Temperature...
Страница 11: ...com Page 11 of 28 EH20B EH35B EH45B EH45C The control panel consists of the following keys Graph of Temperature Control for EH20B EH35B EH45B EH45C LCD Display Control keypress Heating Board Temperatu...
Страница 12: ...ge 12 of 28 EH20D The control panel consists of the following keys Graph of Temperature Control for EH20D Heating Board Indicator light of working status LED display Temperature Controller Switch Temp...
Страница 13: ...rl com Page 13 of 28 EH20S EH35S EH45S The control panel consists of the following keys Graph of Temperature Control for EH20B EH35B EH45B EH45C LCD Display Control keypress Heating Board Temperature...
Страница 14: ...Page 14 of 28 EH20R The control panel consists of the following keys Graph of Temperature Control for EH20R Remote Controller LCD display Temperature Controller Control key press Heating board Temper...
Страница 15: ...28 EG SERIES EG20A Plus EG35A Plus EG37A Plus The control panel consists of the following keys Graph of Temperature Control for EG20A Plus EG35A Plus EG37A Plus Heating Board Temperature Controller Sw...
Страница 16: ...rl com Page 16 of 28 EG20B EG35B EG37B EG37C The control panel consists of the following keys Graph of Temperature Control for EG20B EG35B EG37B EG37C Heating Board Temperature Controller Temperature...
Страница 17: ...emperature Ambient 350 40L 30Wcm switch digital display 5 EH35B 2000W high temperature Ambient 350 40L 30Wcm PID digital display 2 EH45APlus 2800W Graphite Ambient 450 36LX27Wcm switch digital display...
Страница 18: ...orrosive materials are present Electrical Requirements The unit provides extra protection against the risk of electrical shock by grounding appropriate metal parts The extra protection may not functio...
Страница 19: ...arm no 1 AU2 Auxiliary alarm no 2 PRG Program Running Temperature Control EH20A Plus EH35A Plus EH45Plus Under basic display status the temperature can be set by pressing or is the transposition key P...
Страница 20: ...esired holding time can be set on the setpoint Press SET key again to save and quit the set interface The lower line of the LCD screen displays the total running time When the requested temperature re...
Страница 21: ...to enter the function menu of the D controller After entering the menu press and hold the SEL key until the real temperature appears and loose the SEL key to exit the function menu NOTE the function m...
Страница 22: ...o 1 AU2 Auxiliary alarm no 2 PRG Program Running Temperature Control EG20A Plus EG35A Plus EG37APlus Under basic display status the temperature can be set by pressing or is the transposition key Press...
Страница 23: ...hen the desired holding time can be set on the setpoint Press the SET key again to save and quit the set interface The lower line of the LCD screen displays the total running time When the actual temp...
Страница 24: ...n other interface press and hold the key for 3 seconds can rerun the system after finishing the heating method RUN STOP Press and hold for 2s to run stop the unit In set interface press the key to inc...
Страница 25: ...the method will automatically end at this step You can also manually stop the heating by pressing and hold Run Stop key for 2 seconds Realtime Display During running of a method you could check the op...
Страница 26: ...becomes dark The reason is that high temperature condition makes the coating crystallized and reorganized This is not affecting the usage And if the colour becomes white The reason is that the super h...
Страница 27: ...EH EG Series User Manual www labtechsrl com Page 27 of 28 Declaration of Conformity...
Страница 28: ...EH EG Series User Manual www labtechsrl com Page 28 of 28 Spare Parts List...