background image

Instruction Manual

Labnet

Spectrafuge 24D Microcentrifuge

Labnet International

PO Box 841

Woodbridge, NJ 07095

Phone:  732 417-0700

Fax: 732 417-1750

email:  [email protected]

Содержание Spectrafuge 24D

Страница 1: ...Instruction Manual Labnet Spectrafuge 24D Microcentrifuge Labnet International PO Box 841 Woodbridge NJ 07095 Phone 732 417 0700 Fax 732 417 1750 email labnet labnetlink com ...

Страница 2: ...hands in the rotor area unless the rotor is completely stopped NEVER move the centrifuge while the rotor is spinning NEVER use solvents or flammables near this or other electrical equip ment NEVER centrifuge flammable explosive or corrosive materials NEVER centrifuge hazardous materials outside of a hood or proper containment facility ALWAYS load the rotor symmetrically Each tube should be counter...

Страница 3: ... Rotor 3 Rotors and accessories Rotor maintenance Removing and installing the angle rotor Loading the rotor Overloading rotors 4 Operation 6 Attaching rotor lid Closing the lid Lid release Lid lock Speed selection RPM g force Selection of operating time momentary operation Start Stop 5 Service and Maintenance 8 Service Cleaning Disinfection Replacing fuses 6 Troubleshooting 9 7 Where to Call 11 8 ...

Страница 4: ...e unit If this equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Do not operate the centrifuge if any of the following conditions exist The centrifuge has not been installed properly The centrifuge is partially dismantled Service has been attempted by unauthorized or unqualified person nel The rotor has not been installed secur...

Страница 5: ...likely event of a manufacturing fault our one year warranty from the date of delivery covers the centrifuge and the rotor This warranty becomes invalid in the case of incorrect operation use of nonstandard spare parts or accesso ries and unauthorized modification of the rotor or centrifuge Labnet reserves the right to make technical modifications Please see the complete limited warranty statement ...

Страница 6: ...rifuge check that the power source electrical outlet on the wall corresponds to that on the manufacturer s rating label then connect the power cord to the centrifuge and the power source 3 Installation of rotors and rotor maintenance 3 1 Rotors and accessories The following accessories are included or available for the Spectrafuge Angle rotor for 24 x 1 5ml tubes Included Tube measurement 1 5ml 2 ...

Страница 7: ...otor wrench Lift the rotor directly upward in a straight vertical motion 4 11 Possible reason Sample liquid in tubes not balanced Solution Make sure the same volume of liquid is in each tube Possible reason Defective or improperly adjusted balance sensor Solution Call service Er LI I I I Id Lid not closed Possible reason Lid not closed completely Solution Close lid Possible reason Lid lock or sens...

Страница 8: ...ive lid lock Solution Open manually and have unit serviced Possible reason No power from PC board Solution Call for service Possible reason Lid lock is jammed Solution Call for service Possible reason Centrifuge is not receiving power Solution See Centrifuge will not start Centrifuge cannot be started although power is on Possible reason Lid not closed correctly Solution Close lid correctly Possib...

Страница 9: ...otor in the Spectrafuge 24D requires no routine maintenance Any required service should be performed by authorized qualified personnel only Repairs performed by unauthorized personnel may void the warranty 5 2 Cleaning the centrifuge Always keep the centrifuge housing rotor chamber rotor and rotor accessories clean All parts should be wiped down periodi cally with a soft cloth For more thorough cl...

Страница 10: ...he lid lock manually 4 4 Lid lock The centrifuge can be started only with the lid securely closed When a run is started the lid lock automatically activates Do not attempt to open the lid during a centrifuge run At the end of the run the lid will automatically unlock Never attempt to override the lid lock mechanism Doing so is dangerous and could damage the centrifuge 8 4 5 Speed selection see Fig...