VorTemp™ 1550 Shaking Incubator

Instruction Manual

Catalog Numbers: 

S2050A
S2050-230V

Содержание S2050-230V

Страница 1: ...VorTemp 1550 Shaking Incubator Instruction Manual Catalog Numbers S2050A S2050 230V...

Страница 2: ...cement 3 6 2 Attaching the Power Cord 3 6 3 Starting Up Check List 3 6 4 Platforms 3 7 0 Operating Instructions 4 7 1 Control Panel 4 7 2 Basic Operation 4 7 3 Shaking Without Heating 7 7 4 Heating Wi...

Страница 3: ...tform for 50 mL microtubes Instruction manual 3 0 Specifications Power 515W Heater Power 500W Motor Power 15W Fuse 2 x T 3 15A L 250V 230V version 2 x T 6 3A L 250V 120V version Environmental Temperat...

Страница 4: ...the chamber Chamber conditions are monitored by the temperature sensor and the control electronics regulate heater function to maintain the set temperature 5 0 Safety Information NOTE Be careful when...

Страница 5: ...ull the plug by the cord 6 3 Starting Up Check List Unpack and install the device as specified in the previous section Open the lid and attach the microtube platform or the microplate platform Close t...

Страница 6: ...uminates when on or OFF 2 Run green signal light illuminated when the shaker is operating 3 Time yellow signal light illuminated when the unit is set to adjust time 4 RPM yellow signal light illuminat...

Страница 7: ...run continuously set Time on hold The timer is set to hold when HLd is displayed Rotate the encoder under 0 30 or above 99 5 to set this hold function Push encoder knob to adjust the RPM setting 120...

Страница 8: ...lay reads OFF Press Start Stop Button Run and Time are illuminated The timer will count down from set time value 99 4 Stop Encoder Power Run Time min RPM x10 Temp C Start NOTE You cannot adjust the se...

Страница 9: ...temperature control will not be as precise due to lack of airflow over the heating element Maximum set temperature in this program is 70 C 7 5 Additional Operations Viewing the Set Value for RPM Duri...

Страница 10: ...ppears when set RPM oscillates more than 100 RPM in 2 seconds The unit will automatically stop Call for service E 2 1 The temperature sensor is not working properly with regards to the heater The unit...

Страница 11: ...bove Be sure to note whether your value was positive or negative After you have entered the value press the encoder again 3 Press the START STOP button to complete the temperature calibration NOTE Tem...

Страница 12: ...fesciences or contact your local support office Corning s Customer Service team will help arrange local service where available or coordinate a return authorization number and shipping instructions Pr...

Страница 13: ...isting of US medical devices regulatory classifications or specific information on claims visit www corning com resources www labnetlink com For a listing of trademarks visit www corning com clstradem...