Figure 46. WLAN settings
Establish the WLAN connection again according to the instructions in the
Establishing a
WLAN connection
section.
7.3.3.8. Low power mode settings
The following settings can be set in the Low power mode settings menu:
Beacon light adjustment (relay state change setting):
With the beacon light adjustment settings, the relay can be set to change its state back and
forth during the alarm event. This function can be utilized e.g. when an external beacon light
is needed to show the alarm.
Example:
Repeat: 5 s
Duration: 400 ms
The beacon light will flash every 5 seconds and the flash duration is 400 ms.
Repeat: Sets the interval for the relay to change its state (de-energised or energised) in
seconds. You can choose between 2 s, 5 s, 10 s, 30 s and 60 s.
Duration: Set the length of time the relay remains de-energised. You can choose
between 200 ms, 400 ms, 600 ms, 800 ms and 1,000 ms.
Relay 1 and Relay 2: Off/On. Activation of the relay state change.
Once you have made the desired changes, press the
Save
button.
Measure interval:
Repeat: Sets the measurement interval for the idOil device in minutes or hours. You can
choose between 10 min, 30 min, 60 min, 2 h, 3 h, 4 h, 6 h, 8 h, 10 h, 12 h or 24 h.
Start delay: The delay for performing the measurement when the measurement repeat
interval is activated. You can choose between 1 s, 2 s, 3 s, 4 s or 5 s.
Once you have made the desired changes, press the
Save
button.
SMS message receipt interval:
Repeat: The interval at which the idOil device wakes up to detect whether or not settings
messages have been received. You can choose between 12 h, 24 h, 36 h and 48 h. The
time is counted from the connection of voltage to the idOil device.
Once you have made the desired changes, press the
Save
button.
Backlight blinking during alarm:
Installation and Operating Instructions | idOil Solar
42/58