background image

 

Minutes (flashing)

 

Hours (flashing)

 

AIR QUALITY MONITOR 

Instructions manual 

 

INTRODUCTION:

 

Congratulations on purchasing this Air Quality Monitor with wireless 
868 MHz transmission of outdoor temperature and display of indoor 
temperature/humidity, and time. With only four easy to use function 
keys, this innovative product is ideal for use in the home or office.

 

 

FEATURES: 

 

AIR QUALITY MONITOR 
 
 
 
 
 
 
 
 
 

 

 

 

12/24h time display 

 

Temperature display in ºC / ºF 

 

Indoor and outdoor temperature display with MIN/MAX records

 

 

Indoor humidity display in RH% 

 

Air quality alert  

 

Air quality indicator 

 

Low battery indicator 

 

THE OUTDOOR TEMPERATURE TRANSMITTER 

 

Remote transmission of outdoor 
temperature to 

the air quality monitor

 

by 868 MHz signal 

 

Rain proof casing 

 

Wall mounting case 

 
 

 
 
 
 

TO INSTALL AND REPLACE BATTERIES IN THE 
TEMPERATURE TRANSMITTER 

The temperature transmitter uses 2 x AA, IEC, 
LR6, 1.5V batteries. To install and replace the 
batteries, please follow the steps below: 
1. 

Remove the cover. 

2. 

Insert the batteries, observing the 
correct polarity (see marking). 

3. 

Replace the battery cover on the unit. 

 
 

TO INSTALL AND REPLACE BATTERIES IN THE AIR 
QUALITY MONITOR 

The air quality monitor uses 2

 x C, IEC LR14, 1.5V 

battery. To install 

and replace the battery, please follow the steps below: 

 

1. 

Remove the cover at the back of the air quality monitor.  

2. 

Insert batteries observing the correct polarity (see marking). 

3. 

Replace compartment cover. 

 

SETTING UP: 

1. 

First, insert the batteries in the transmitter 

(see “I

nstall and 

replace batteries in the temperature transmitter

 

above

). 

2. 

Within 2 minutes of powering up the transmitter, insert the 
batteries in the 

Temperature Station (see “I

nstall and replace 

batteries in the air quality monitor

 

above

). 

3. 

The indoor temperature/humidity and the time as 0:00 will be 
displayed. If these information are not displayed on the LCD 
after 60 seconds, remove the batteries and wait for at least 60 
seconds before reinserting them. Once the indoor data is 
displayed user may proceed to the next step. 

4. 

The air quality monitor will start receiving data signal from the 
transmitter. The outdoor temperature data should then be 

displayed on the air quality monitor. If this does not happen 
after 2 minutes, the batteries will need to be removed from both 
units and reset from step 1 

 

Note:  

 

The Equivalent CO

2  

ppm will only be displayed after 30 

minutes. 

 

The air quality sensor will take up to 5 days after inserting 
batteries to condition itself for the room it is placed. If the unit is 
placed into another room, there might be a reconditioning time 
of several days as well. 

 

BATTERY CHANGE: 

It is recommended to replace the batteries in the unit regularly to 
ensure optimum accuracy of the unit (Battery life See 

Specifications

 

below). 

 

Please participate in the preservation of the 
environment. Return used batteries to an authorised 
depot. 

 

 

KEY FUNCTIONS: 

The Air Quality Monitor has 

4 easy-to-use keys:

 

 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

SET key: 

 

Press and hold to enter the manual setting modes: 12/24 hour 
time display, manual time, and ºC / ºF temperature display 
settings 

 

+ key: 

 

Press to change, set, toggle all manual settings 

 

AL key: 

 

Stop the LED air quality alert

 

 

Exit the manual setting mode 

 

MIN/MAX key: 

 

Press to toggle between MAX/MIN and current indoor 
temperature/humidity and outdoor data 

 

Exit the manual setting mode 

 

LCD SCREEN 

 
 
 
 
 
 
 

 
 

 
 
 
 
 
 
 
 
 

* When the signal is successfully received by the temperature station, 
the outdoor transmission icon will be switched on. (If not successful, 
the icon will not be shown on LCD). The user can then easily see 
whether the last reception was successful (icon on) or not (icon off). 
On the other hand, the short blinking of the icon shows that a 
reception is currently taking place. 

 

MANUAL SETTINGS: 

The following manual settings can be done in the setting mode: 

 

12/24 hour time setting 

 

Time setting 

 

ºC / ºF temperature display setting 

 

Press and hold the SET button for about 3 second to enter the setting 
mode: 

 

12/24 HOUR TIME DISPLAY SETTING

 

 
 
 
 
 
 

 

1. 

“12hr” or “24hr” flashes in the LCD. (default 24hr) 

2. 

Press the 

+

 key to 

select the “12hr” or “24hr” display mode. 

3. 

Confirm with the 

SET

 key and enter the 

Manual time setting

 

MANUAL TIME SETTING 

 

 

 

 
 

 

To set the clock: 
1. 

The hour digits start flashing in the time display section. 

2. 

Use the 

+

 key to adjust the hours and then press 

SET 

key to go 

to the minute setting. 

3. 

The minute will be flashing. Press the 

+

 key to just the minutes. 

4. 

Confirm with the 

SET

 key and 

enter

 the 

°C/°F temperature 

unit setting

 

°C/°F TEMPERATURE UNIT SETTING

 

 

 
 

 
 

 

The default temperature reading is set to °C (degree Celsius). To 
select °F (degree Fahrenheit): 
1. 

The “°C” will be flashing, use the 

+

 

key to toggle between “°C” 

and “°F”. 

2. 

Confirm with the 

SET

 key and exit the 

manual settings

 

AIR QUALITY ALERT: 

The LED will flash when: 

 

Equivalent CO

2  

ppm

 

> 1500ppm: 

LED alert blinks at a slower speed (1.5s).  

 

Equivalent CO

2  

ppm

 

> 2000ppm: 

LED alert blinks at faster speed (0.5s). 

 

Note about the air quality alert: 

 

The air quality alert will sound for a maximum duration of 30 
minutes.  

 

To stop the alert, press any key. 

 

AIR QUALITY INDICATOR 

The air quality indicator is located on the bottom of the LCD. It 
changes from

 

GREEN 

(GOOD)

 to RED

 (BAD

) by measuring the

 

Equivalent CO

2  

ppm

.   

 
 
 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

* The air quality value shown, after sensor conditioning, may /- 
250 ppm.

 

 

Note: 

A 9-

level bar graph is used to indicate “GREEN” to “RED” air quality 

level in the surrounding environment: 

 

Levels 

Equivalent CO

2  

ppm

 

GREEN (level 1) 

450 

– 600ppm 

Level 2 

650 

– 800ppm 

Level 3 

850 

– 

1000ppm

 

Level 4 

1050

 

– 1200ppm 

Level 5 

1250 

– 1500ppm 

Level 6 

1550 

– 1800ppm 

Level 7 

1850 

– 2100ppm 

Level 8 

2150 

– 2400ppm 

RED (level 9) 

≥ 2450ppm 

 

DISPLAY OF MIN/MAX TEMPERATURE AND HUMIDITY 
RECORDS: 

1. 

In normal display mode, press the 

MIN/MAX

 key once. The 

MIN indoor/outdoor temperature and indoor humidity will be 
shown in the LCD.  

2. 

Then press the 

MIN/MAX

 key one more time, the MAX 

indoor/outdoor temperature and indoor humidity will be shown 
in the LCD.

 

3. 

Press one more time the 

MIN/MAX

 key to go back to the 

normal display. 

 

RESETTING THE INDOOR MAXIMUM/ MINIMUM 
RECORDS 

 

Note: 

The indoor/outdoor minimum and maximum and humidity 

records will be reset at the same time 

 

1. 

Press and hold the MIN/MAX key for about 3 seconds, this will 
reset the indoor/outdoor MIN/MAX temperatures and humidity 
to the current temperature and humidity. 

 

TEMPERATURE TRANSMITTER 

The outdoor temperature is measured and transmitted every 4 
seconds. 
The range of the temperature transmitter may be affected by the 
temperature. At cold temperatures the transmitting distance may be 
decreased. Please bear this in mind when placing the transmitter.

 

 

868 MHz RECEPTION: 

If the outdoor data are not being received within three minutes after 
setting up (or outdoor display always show “- -. -” in the outdoor 
sections of the temperature station during normal operation), please 
check the following points: 
1. 

The distance of the 

air quality monitor or transmitter 

should be 

at least 2 meters away from any interfering sources such as 
computer monitors or TV sets. 

2. 

Avoid placing the transmitters onto or in the immediate 
proximity of metal window frames. 

3. 

Using other electrical products such as headphones or 
speakers operating on the 868MHz-signal frequency may 
prevent correct signal transmission or reception. Neighbors 
using electrical devices operating on the 868MHz-signal 
frequency can also cause interference. 

 

Note:

 

 

When the 868MHz signal is received correctly, do not re-open the 
battery covers of either the transmitter or 

air quality monitor

, as the 

batteries may spring free from the contacts and force a false reset. 
Should this happen accidentally then reset all units (see 

Setting up 

above) otherwise transmission problems may occur. 

 

The transmission range is about 100 m from the transmitter to the 

air 

quality monitor

 (in open space). However, this depends on the 

surrounding environment and interference levels. If no reception is 
possible despite the observation of these factors, all system units 
have to be reset (see 

Setting up

). 

 
 
 
 
 
 
 

 

Function keys 

LCD 

display 

Battery compartment 

SET key 

AL key 

+ key 

MIN/MAX 
key 

Time 

Low battery icon (air quality monitor)

 

Indoor 

temperature 

in ºC/ºF 

Equivalent CO

2  

ppm display 

Indoor relative 
humidity % RH

 

Outdoor reception 
signal* 

Low battery 
indicator 
(transmitter)

 

Flashing 

Flashing 

Air quality indicator 

Bar graph 

Equivalent CO

2  

ppm (parts per 
million) value* 

Air quality indicator

 

 

 

 

 

 

Содержание WS272

Страница 1: ...ing the correct polarity see marking 3 Replace the battery cover on the unit TO INSTALL AND REPLACE BATTERIES IN THE AIR QUALITY MONITOR The air quality monitor uses 2 x C IEC LR14 1 5V battery To install and replace the battery please follow the steps below 1 Remove the cover at the back of the air quality monitor 2 Insert batteries observing the correct polarity see marking 3 Replace compartment...

Страница 2: ... and hold to enter the manual setting modes 12 24 hour time display manual time and ºC ºF temperature display settings key Press to change set toggle all manual settings AL key Stop the LED air quality alert Exit the manual setting mode MIN MAX key Press to toggle between MAX MIN and current indoor temperature humidity and outdoor data Exit the manual setting mode LCD SCREEN When the signal is suc...

Страница 3: ... just the minutes 4 Confirm with the SET key and enter the C F temperature unit setting C F TEMPERATURE UNIT SETTING The default temperature reading is set to C degree Celsius To select F degree Fahrenheit 1 The C will be flashing use the key to toggle between C and F 2 Confirm with the SET key and exit the manual settings AIR QUALITY ALERT The LED will flash when Equivalent CO2 ppm 1500ppm LED al...

Страница 4: ...s the transmitting distance may be decreased Please bear this in mind when placing the transmitter 868 MHz RECEPTION If the outdoor data are not being received within three minutes after setting up or outdoor display always show in the outdoor sections of the temperature station during normal operation please check the following points 1 The distance of the air quality monitor or transmitter shoul...

Страница 5: ... and casings use a soft damp cloth only Do not use solvents or scouring agents as they may mark the LCD and casings Do not submerge the unit in water Special care shall be taken when handling a damaged LCD display The liquid crystals can be harmful to user s health Do not make any repair attempts to the unit Return them to their original point of purchase for repair by a qualified engineer Opening...

Страница 6: ...he quality of environment As stated on the gift box and labeled on the product reading the User manual is highly recommended for the benefit of the user This product must however not be thrown in general rubbish collection points The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place This pro...

Отзывы: