Page 5 

 

Remote Temperature is stuck or HH.H, LL.L 

 

Explanation: These symbols are error messages indicating the remote sensor is 

outside of its readable range. 

 

 

Chec

Batteries.

 Overpowered or underpowered batteries can cause this 

reading. 

 

Replace remote sensor. 

Note: The last remote reading may remain (not change) for several hours when 

connection is lost. The remote temperature reading will flash when the connection 

is first lost or intermittent.  

 

Remote sensor drains batteries quickly 

 

 

Test a new set of alkaline batteries. Write down the date of installation and the 

voltage of the batteries. 

 

When the batteries fail, please note the date and voltage again.  

 

Check the 

distance

 and 

resistance

 between the remote sensor and atomic clock. 

Remote sensors at the end of the range may work while batteries are fresh but 

not after they drain a bit. 

 

Check for leaking batteries, which may damage the remote sensor. 

 

Battery life is over 24 months when using reputable battery brands for both 

Alkaline and Lithium batteries. 

 

Remote sensor fell. The sensor no longer works 

 

Explanation: If there is no physical damage to the remote sensor, the fall may not 

have caused internal damage. A fall can shock the remote sensor or the batteries in 

the remote sensor. Batteries that have fallen on a hard surface may be damaged 

and unable to function properly. 

 

 

Complete a 

Restart

 with fresh batteries. 

 

Use 

Batteries 

dated at least six years in advance of the current year. Batteries 

dated earlier than six years from now may still work, but may be unstable in 

performance. 

Note: A remote sensor that has fallen into puddle, snow, or other standing water, 

will likely have water damage and need to be replaced. Remote sensors are water 

resistant, not waterproof. 

 

Replacement Remote sensors 

 

 

Visit your local Retailer or La Crosse Technology® Store 

http://store.lacrossetechnology.com/

  

Note: Be sure to order the correct model and frequency to avoid receiving the 

incorrect item.  

 

Call La Crosse Technology® Store at 608-785-7939 or e-mail from the store 

website if you are unsure about the correct item to order. Each item carries the 

original new product warranty and includes access to La Crosse Technology® 

technical support. 

 

Содержание 513-1919

Страница 1: ...urate Remote Temperature Reading 4 Intermittent Remote Temperature 4 Remote Temperature is stuck or HH H LL L 5 Remote sensor drains batteries quickly 5 Remote sensor fell The sensor no longer works 5 Display Outdoor Temperature or Seconds 6 Mounting Positioning Remote sensor 6 Fahrenheit Celsius 6 12 Hour Time Format 7 Supported Time Zones 7 Dashes HHH LLL or Stuck Indoor Temperature 7 Does the c...

Страница 2: ...duces the chance of RF radio frequency interference from the battery compartment Digital Clock Factory Restart Explanation The factory restart returns the clock and outdoor sensor to an out of the box default state and often resolves an issue Factory Restart 1 Remove all power from outdoor sensor and clock 2 Press one of the buttons on the clock at least 20 times to clear all memory 3 Verify that ...

Страница 3: ...e area will flash 3 Wait for 2 minutes for the remote temperature to appear on the atomic clock Factory Restart If the above procedure does not work please try the factory reset Remote Temperature Signal Strength Explanation The atomic clock will search for the remote temperature remote sensor for 3 minutes after batteries are installed or when the MINUS button is held for 3 seconds The antenna sy...

Страница 4: ...t Remote Temperature Explanation Intermittent problems are the hardest to resolve RF radio frequency communication may come and go occasionally This can be normal in some environments e g moister climates If remote sensor signal is lost please wait 2 4 hours for the signal to reconnect on its own Move the remote sensor to a closer location Distance Resistance can cause loss of remote sensor signal...

Страница 5: ...Alkaline and Lithium batteries Remote sensor fell The sensor no longer works Explanation If there is no physical damage to the remote sensor the fall may not have caused internal damage A fall can shock the remote sensor or the batteries in the remote sensor Batteries that have fallen on a hard surface may be damaged and unable to function properly Complete a Restart with fresh batteries Use Batte...

Страница 6: ...ng RF radio frequency signal Do not mount the remote sensor on a metal fence This significantly reduces the effective range Remote sensors are water resistant not waterproof Indoor or Outdoor Mount remote temperature sensor vertically Avoid more than one wall between the remote sensor and the atomic clock The maximum transmitting range in open air is over 200 feet 60 meters Obstacles such as walls...

Страница 7: ...oes the clock have a backlight No as this clock is battery operated there is no backlight Time is off by hours Check to see if the WWVB Tower icon appears on the atomic digital clock If not the digital clock has not received a WWVB time signal in the past 24 hours Reposition the digital clock with the front or back facing Colorado Check that the Time Zone selected correctly reflects your location ...

Страница 8: ...ess the buttons to turn OFF the beep sound 3 Press the SET button to confirm and select Atomic ON OFF 4 ATOMIC ON will show Press the buttons to turn OFF the Atomic time signal Note If ATOMIC is set to OFF you will skip the next two items and go directly to the hour 5 Press the SET button to confirm and select Daylight Savings Time ON OFF 6 DST ON will show Press the buttons to turn that OFF if yo...

Страница 9: ...Hour will show 2 Use the button to select 3 Hold then release ALARM 3 seconds Alarm Minutes will show 4 Use the button to select 5 Press and release the ALARM button to confirm and exit Activate Deactivate Time Alarm The alarm is active when set From normal time display Press and release and release the ALARM button to deactivate or activate the alarm The alarm icon clock will show when active Sno...

Страница 10: ...ctly Batteries may be overpowered or underpowered Remove batteries from digital clock Press any button 20 times Leave the batteries out of the display for 2 hours Insert batteries into the digital clock Day of the week is incorrect Check the year setting in the program menu The day of the week sets automatically based on the setting of the year month and date Digital clock drains batteries quickly...

Страница 11: ...La Crosse Technology Ltd Page 11 Press any button 20 times Leave the batteries out of the display for 2 hours Insert batteries into the digital clock ...

Отзывы: