background image

 
 

9

D. EL 

BACKLIGHT 

 

1. 

The projection alarm has an EL backlight designed for night-viewing. This will light up 
for 4 seconds whenever the snooze button is pressed.

 

2. 

The EL backlight cannot be turned on constantly; this would drain the batteries. 

 

E. INDOOR 

TEMPERATURE 

 

1. 

The projection alarm measures indoor temperature with an internal sensor.  

2. 

This temperature is displayed in 

°

F.

 

3. 

The indoor temperature will take time to adjust to the surrounding temperature as the 
sensor is inside the case. 

4. 

If the remote temperature is placed next to the projection alarm, more often than not 
the temperature will not be exact with one another. This is not a defect, but simply 
reflects the difference in measuring methods. The remote temperature is designed for 
changing temperature at a wide range.

 

 

F. INDOOR 

HUMIDITY 

 

1. 

The projection alarm measures indoor humidity with an internal sensor.  

2. 

This humidity is displayed as a percentage (%).

 

3. 

The indoor humidity will take time to adjust to the surrounding humidity as the sensor 
is inside the case. 

 

G. REMOTE 

TEMPERATURE 

 

1. 

The projection alarm comes with a remote temperature sensor. When set up properly, 
the projection alarm will receive and display the remote temperature.

 

2. 

It is important to power up the sensor first, then the projection alarm. If batteries are 
removed in the remote, the projection alarm MUST be re-set by removing power 
sources and re-starting.

 

3. 

The remote temperature is measured within the remote temperature and transmitted 
to the projection alarm. If outdoor temperature is desired, simply mount the remote 
sensor outside. It is recommended to mount the sensor on the North side of the house 
away from sources of heat or cold (away from direct sunlight, windows, vents, etc.). 

4. 

The range of the sensor is 80 feet in open space. While the signal is able to penetrate 
walls, it will decrease the range. Concrete and metal structures offer the most 
resistance.

 

5. 

The sensor should not be mounted on a metal surface.  

6. 

The sensor and projection alarm should be kept away from other sources of possible 
interference including cordless appliances (telephones, baby monitors), microwave 
ovens, and other strong electrical appliances.

 

7. 

The remote temperature is displayed in 

°

F.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание WT-5120 433

Страница 1: ...WT 5120 433 MHz Radio Controlled Projection Alarm Instruction Manual...

Страница 2: ...6 Function Buttons 6 Manual Time Setting 6 Time Zone Setting 6 7 Daylight Saving Time DST Setting 7 Features Operations Features 8 Radio Controlled Time 8 Projection 8 EL Backlight 9 Indoor Temperatur...

Страница 3: ...ver due to the nature of the Earth s Ionosphere reception is very limited during daylight hours The projection alarm will search for a signal every night when reception is best The WWVB radio station...

Страница 4: ...or humidity after the 15 minutes please retry the set up as stated above After both indoor and outdoor temperatures are displayed for 15 minutes you can place your sensor outdoors and set your time Th...

Страница 5: ...ote temperature will be displayed Also the time will appear as The WWVB search is automatically initiated and a tower icon appears and flashes with the time colon no tower icon will appear if the WWVB...

Страница 6: ...e on the top The function buttons are labeled AL HOUR light direction icon MODE MIN and SNOOZE the top bar C MANUAL TIME SETTING 1 Hold down the MODE MIN button for 3 seconds the time will flash in th...

Страница 7: ...ime according to Daylight Saving Time in the spring and fall For areas that do not recognize DST changes Arizona and parts of Indiana turn the DST OFF 1 Hold down the MODE MIN button for 3 seconds the...

Страница 8: ...measuring a second as 9 192 631 770 vibrations of a Cesium 133 atom in a vacuum 7 For more detail visit http www boulder nist gov timefreq htm To listen to the NIST time call 303 499 7111 This number...

Страница 9: ...nsor is inside the case G REMOTE TEMPERATURE 1 The projection alarm comes with a remote temperature sensor When set up properly the projection alarm will receive and display the remote temperature 2 I...

Страница 10: ...will be displayed above the time display when the alarm is activated 3 TURNING ALARM OFF WHILE SOUNDING a While the alarm is sounding press and release the SNOOZE bar to disable the alarm for 10 minu...

Страница 11: ...the mounting surface to ensure a secure hold The mounting surface should be smooth and flat 2 Remove the protective strip from one side of the tape Adhere the tape to the designated area on the back...

Страница 12: ...omputers or other radio controlled clocks 4 Remove batteries for five minutes reinsert and leave the unit alone overnight without pressing buttons 5 If problems persist contact La Crosse Technology Pr...