background image

 
 

5

Battery 
Cover 

 

DETAILED SET-UP GUIDE 
 

II. 

BATTERY INSTALLATION

 

 

A. REMOTE 

TEMPERATURE 

SENSOR 

 

1. 

Remove the battery cover.

 

2. 

Observing the correct polarity, install 2 AA batteries.  The 
batteries will fit tightly (to avoid start-up problems make 
sure that they do not spring free during installation).

 

3. 

Replace the battery cover.

 

 
 

 

B. PROJECTION 

ALARM

 

 

1. 

Remove the battery cover.

 

2. 

Observe the correct polarity, and install 2 AA batteries.

 

3. 

In addition or instead of inserting batteries, the AC adapter can be used. Simply plug 
the adapter into the receptacle on the 
underneath of the alarm clock and then plug 
in adapter.

 

4. 

Replace the battery cover. 

5. 

The projector will activate and remain on if 
the alarm clock is plugged in. If only batteries 
are used, the projector will only be activated 
when a button is pressed. The projection is a 
red light, not harmful under normal usage, 
although care should be taken to not look 
directly into the light. 
 

Notes:

  

 

After the batteries have been installed a tone will sound, and the LCD (Liquid 
Crystal Display) will activate. 

 

The indoor temperature/humidity and the remote temperature will be displayed.  
Also, the time will appear as “-:--”.   

 

The WWVB search is automatically initiated, and a tower icon appears and 
flashes with the time colon (no tower icon will appear if the WWVB is too weak to 
be detected, and the time display will remain on “-:--”). 

 

While the WWVB search is being conducted various numbers will appear in the 
time display. 

 

After 15 minutes, the projection alarm will either display the WWVB time, or 
discontinue the search if the time is not found. If the search is cancelled “-:--” will 
remain in the time LCD.  

 

The projection alarm will conduct a WWVB search every hour until the first signal 
is found.  

 

Once the WWVB time is found, a search is automatically conducted nightly at 
midnight. 

 

If the signal is found at midnight, the tower icon will remain, if not, another search 
will take place every hour (until 6:00 am) until the signal is found successfully. 

 

If no signal is found during this period, the tower icon will not appear and the 
clock will search again at 12:00 am the next night. 

 

The radio-controlled time receiver is located on the bottom side of the projection 
alarm.  When using the AC adaptor be sure to keep the adapter cord away from 
the bottom side of the unit as if the wire is too close it can cause weakened 
reception sensitivity. 

 
 

AC adapter 
receptacle  

Содержание WT-5120 433

Страница 1: ...WT 5120 433 MHz Radio Controlled Projection Alarm Instruction Manual...

Страница 2: ...6 Function Buttons 6 Manual Time Setting 6 Time Zone Setting 6 7 Daylight Saving Time DST Setting 7 Features Operations Features 8 Radio Controlled Time 8 Projection 8 EL Backlight 9 Indoor Temperatur...

Страница 3: ...ver due to the nature of the Earth s Ionosphere reception is very limited during daylight hours The projection alarm will search for a signal every night when reception is best The WWVB radio station...

Страница 4: ...or humidity after the 15 minutes please retry the set up as stated above After both indoor and outdoor temperatures are displayed for 15 minutes you can place your sensor outdoors and set your time Th...

Страница 5: ...ote temperature will be displayed Also the time will appear as The WWVB search is automatically initiated and a tower icon appears and flashes with the time colon no tower icon will appear if the WWVB...

Страница 6: ...e on the top The function buttons are labeled AL HOUR light direction icon MODE MIN and SNOOZE the top bar C MANUAL TIME SETTING 1 Hold down the MODE MIN button for 3 seconds the time will flash in th...

Страница 7: ...ime according to Daylight Saving Time in the spring and fall For areas that do not recognize DST changes Arizona and parts of Indiana turn the DST OFF 1 Hold down the MODE MIN button for 3 seconds the...

Страница 8: ...measuring a second as 9 192 631 770 vibrations of a Cesium 133 atom in a vacuum 7 For more detail visit http www boulder nist gov timefreq htm To listen to the NIST time call 303 499 7111 This number...

Страница 9: ...nsor is inside the case G REMOTE TEMPERATURE 1 The projection alarm comes with a remote temperature sensor When set up properly the projection alarm will receive and display the remote temperature 2 I...

Страница 10: ...will be displayed above the time display when the alarm is activated 3 TURNING ALARM OFF WHILE SOUNDING a While the alarm is sounding press and release the SNOOZE bar to disable the alarm for 10 minu...

Страница 11: ...the mounting surface to ensure a secure hold The mounting surface should be smooth and flat 2 Remove the protective strip from one side of the tape Adhere the tape to the designated area on the back...

Страница 12: ...omputers or other radio controlled clocks 4 Remove batteries for five minutes reinsert and leave the unit alone overnight without pressing buttons 5 If problems persist contact La Crosse Technology Pr...

Страница 13: ...ity Measuring range 1 99 Checking intervals Every 10 seconds Power source AC Adapter included Input 120VAC 60Hz Output DC 3 2V 100MA Battery type Projection Alarm 2 x AA 1 5V Alkaline optional Sensor...

Страница 14: ...Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center Your La Crosse Technology Ltd warranty covers all defects in material and workmanship with the following specified...

Страница 15: ...d and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their consequences All trademarks and patents are acknowledged FCC DISCLAIMER This device c...

Отзывы: