background image

Page | 3

Wi-Fi Wind Station

 1. Insert 2 - C batteries into your LTV-W1 Wind Sensor.
2. Insert 2 - AA batteries into your LTV-TH1 Thermo-Hygro Sensor.
3. 5 volt power cord (required) into V21-WTHv2 station 

    *3-AA batteries for optional backup of your time and date
4. Download the La Crosse View™ App (App Store or Google Play)
5. Follow along with our instructional videos to connect your station to the app:

   

http://bit.ly/LaCrosseView_Support_Vid_01_1

   

http://bit.ly/LaCrosseView_Support_Vid_01_2

4. Mount your sensors in appropriate locations.
*Battery operation only, station will not update sensor or Wi-Fi data. Power cord is required.

QUICK SETUP

THERMO-HYGRO 

Keep out of direct sunlight & ensure the sensor is well-ventilated.

• We recommend mounting it on a north-facing wall under an eave or deck for best results. 

WIND SPEED

Ensure the sensor is mounted vertically – an unobstructed rooftop is ideal.

• Your wind sensor should be the tallest object in the area to avoid educed wind speed values.

QUICK MOUNTING TIPS

BUTTON FUNCTIONS

Buttons located on top of your Wind Station

ALERTS

Hold to set alerts. Press to confirm setting and move to next alert.

WIND, TEMP

Press to view history.

+ or –

Use + or – to adjust values in settings. Hold to adjust quickly.

+ & –

Hold both buttons to search for Wi-Fi.

SET

Press to view Wi-Fi Status. Hold for basic settings.

SENSOR

Press to view sensor ID numbers, then hold PLUS (+) to search, or hold 

MINUS (–) to remove.

LIGHT

Press to adjust brightness.

ALERTS & LIGHT

Hold both to Factory Reset Station. 

All sensor ID’s, History, and Wi-Fi settings will be reset.

Содержание V21-WTHv2

Страница 1: ...w Professional Weather Station and welcome to the La Crosse Technology family This product was designed with you in mind by our hometown team of weather enthusiasts based in La Crosse Wisconsin Model...

Страница 2: ...pport Specifications FCC Statement 3 3 3 4 5 6 7 7 8 8 8 9 10 10 11 11 12 13 14 14 15 15 15 15 16 17 17 18 20 20 20 20 21 22 Quick Setup Quick Mounting Tips Button Functions Weather Station Icons Conn...

Страница 3: ...ure the sensor is well ventilated We recommend mounting it on a north facing wall under an eave or deck for best results WIND SPEED Ensure the sensor is mounted vertically an unobstructed rooftop is i...

Страница 4: ...Icon Trend Arrows Fahrenheit or Celsius Temperature Percentage Relative Humidity Icon Temperature Icon Connected stations offer the ability to display custom data controlled with the La Crosse View a...

Страница 5: ...load the free La Crosse View app onto your mobile device LAUNCH FOLLOW Open the La Crosse View app and follow the on screen instructions HAVING TROUBLES CONNECTING Make sure your mobile device is conn...

Страница 6: ...nd Speed Internet Wind Direction Indoor Outdoor Temperature Feels Like Temperature Indoor Outdoor Humidity 12 Hour Forecast Internet Time and Calendar Advance Forecast Icons Daily Forecast HIs LOs Cha...

Страница 7: ...NCED FORECAST CHANCE OF PRECIPITATION FORECAST FORECAST FORECAST FORECAST FORECAST FORECAST FORECAST FORECAST FORECAST FORECAST FORECAST FORECAST IMPORTANT There may be small discrepancies between dat...

Страница 8: ...ll show Current Outdoor Temperature as the Feels Like Temperature Note When you have a high humidity reading but the temperature is not over 80 F the Feels Like temperature will remain the same as the...

Страница 9: ...TX button press the TX button to force a signal 2 Scan sensor bar code ID so it will read in the La Crosse View app Details Open your La Crosse View app to add sensors Watch the video for adding devi...

Страница 10: ...yed ALL OK CONNECTED Station is connected all the way through to the La Crosse View app Status Messages on you station will let you know if there are issues Press and release the SET button to view th...

Страница 11: ...e Sensor Factory Restart Station Your station has 5 levels of brightness for the backlight Press and release the LIGHT button to adjust the backlight at 5 levels of intensity Levels OFF 0 level 1 1 5...

Страница 12: ...view previous months Year Defined by Calendar Year i e January 1 December 31 WIND SPEED READINGS HISTORY Wind Speed Reflects highest current wind speed Top Speed Reflects highest wind speed in the pas...

Страница 13: ...xisting record Viewing order Outdoor HI Temp with Time Date Outdoor LO Temp with Time Date Outdoor HI Humidity with Time Date Outdoor LO Humidity with Time Date Indoor HI Temp with Time Date Indoor LO...

Страница 14: ...you wish to set this alert value press the or buttons to arm this alert ON 4 When the alert is armed ON press and release the ALERTS button and the alert value will flash 5 Press the or buttons to cha...

Страница 15: ...e alert from sounding The alert icon will continue flashing while alert value is in alert range Disarm the alert to stop the alert entirely ARM DISARM ALERTS ACTIVE ALERT Your station and each sensor...

Страница 16: ...utomatically search for a replacement sensor of the same type Example Delete a Wind sensor the station will search for a new Wind sensor 5 If replacing a sensor insert batteries into the new sensor On...

Страница 17: ...on will reset and search for all sensors 3 Allow up to 3 minutes to reacquire all sensors 4 You will need to reconnect to your La Crosse View app by selecting CONNECT WIFI from the menu in your La Cro...

Страница 18: ...the wind cups on top The maximum wireless transmission range to the station is up to 400 feet 121 meters in open air not including walls or trees 1 Use screws through the bottom of the mounting brack...

Страница 19: ...Watch sensor mounting video http bit ly TH_SensorMounting LED Light AA AA Battery Cover Hole for mounting TX F C Press TX to send a signal Press F C to select Fahrenheit or Celsius display on sensor...

Страница 20: ...of battery most suitable for intended use Replace all batteries of a set at the same time Clean the battery contacts and also those of the device prior to battery installation Ensure the batteries ar...

Страница 21: ...ptional Battery Backup LTV TH1 Thermo hygro Sensor LTV W1 Wind Speed Sensor 5 0 Volt 500mA power cord included Required AC6 HX06 0500600 AU 001 Input 100 240V 0 3A 50 60Hz 3 AA batteries not included...

Страница 22: ...Statement This device complies with FCC radiation exposure limits set forth for an uncontrolled environment and it also complies with Part 15 of the FCC RF Rules This equipment must be installed and...

Отзывы: