background image

La Crosse Technology, Ltd. www.lacrossetechnology.com/support 

Page 7 

 

3.  Press the DOWN ARROW button to disarm the selected alert. 

Note:

 When no temperature alerts are set, the Temperature Alert area will show ALERTS OFF. 

 
Active Temperature Alert  

 

 

When temperature alert sounds, the corresponding alert icon (bell) will flash. 

 

The alert beeps once every minute, until the temperature is out of alert range. 

 

Press any button to stop alert. The alert symbol will still show. 

 

Temperature Station 

 

How tall are the time numbers? 

 

The time numbers are 0.5 inches tall. 

 

Power Requirements 

 

  2-AA Alkaline batteries power this temperature station. 

 

12-Hour or 24-Hour time format 

 

  Time can display in 12-hour (am, pm) or 24-hour format.  

  Default is 12-hour time. 

  Use the 

Program Menu 

to switch time formats. 

 

Fahrenheit/Celsius 

 

 

  

Use th

program menu

 to switch between Fahrenheit and Celsius. 

 

Dashes, HH.H, LL.L or stuck Indoor Temperature 

 

Explanation: 

These symbols are error messages indication the indoor sensor is outside of its readable 

range. For indoor readings, this is generally a power related issue.  
 

 

Batteries 

may be overpowered or underpowered. Remove batteries from the temperature station.  

  Press any button 20 times. Leave the temperature station unpowered for 1-2 hours.  

  Install fresh Alkaline batteries with correct polarity.  

  If the indoor temperature is still shows dashes, HH.H or LL.L, the temperature station may need 

replacement. 

 

Inaccurate Indoor Temperature Reading 

 

Explanation: 

When the indoor temperature is inaccurate, it is often due to the location of the display or 

overpowered/under powered batteries. You can test the accuracy at you home.

 

 
Side-by-side test:

 Bring the outdoor sensor in the house and place it next to the temperature station for 

2 hours.  

  Compare indoor and outdoor temperature. The temperature should be within 4 degrees to be within 

tolerance.  

  Look for heat sources such as sunlight, door or window frames or reflected heat or cold near the 

temperature station. 

 

Check

 

batteries

. 

 

Set Time Alarm 

 

In normal mode, hold the TIME ALARM button for three seconds to enter alarm set mode. 
1. 

HOUR: The

 Hour

 will flash, use the ARROW buttons to set the hour, and press TIME ALARM button 

to confirm and switch to minutes.  

2. 

MINUTES: The 

Minutes

 will flash, use the ARROW buttons to set the minutes, and press TIME 

ALARM button to confirm. 

Содержание T83639

Страница 1: ...oor Temperature Reading 3 Intermittent Outdoor Temperature 3 Outdoor Temperature is stuck or HH H LL L 4 Outdoor sensor drains batteries quickly 4 Outdoor sensor fell The sensor no longer works 4 Temperature Trend Arrows 5 MIN MAX Temperature readings 5 Mounting Positioning Outdoor sensor 5 Position Temperature Station 5 Distance Resistance Interference 6 Temperature Alerts 6 Temperature Station 7...

Страница 2: ...to an out of the box state and often resolves an issue Factory Restart 1 Remove all power from outdoor sensor and temperature station 2 Press one of the buttons on the temperature station at least 20 times to clear all memory 3 Verify that the temperature station is blank before proceeding there are some painted lines that will not disappear 4 Leave batteries out of both units for 15 minutes very ...

Страница 3: ...connection between the outdoor sensor and the temperature station Turn the temperature station 90 degrees towards the outdoor sensor to provide better reception This allows more antenna surface to face the outdoor sensor signal Try the quick connect or factory restart Power Requirements 2 AA batteries power the outdoor sensor We recommend Alkaline batteries for the outdoor sensor You may choose to...

Страница 4: ...t of alkaline batteries Write down the date of installation and the voltage of the batteries When the batteries fail please note the date and voltage again Check the distance and resistance between the outdoor sensor and temperature station Outdoor sensors at the end of the range may work while batteries are fresh but not after they drain a bit Check for leaking batteries which may damage the outd...

Страница 5: ...station in the home Wait approximately 1 hour before permanently mounting the outdoor sensor to ensure that there is proper reception POSITION Mount outdoor temperature outdoor sensors vertically Protect the outdoor sensor from standing rain or snow and from the overhead sun which can cause it to read incorrectly Mounting under an eave or deck rail works well If you choose you can construct a smal...

Страница 6: ... signal Do not mount the outdoor sensor on a metal fence This significantly reduces the effective range Interference Consider items in the signal path between the outdoor sensor and the temperature station Sometimes a simple relocation of the outdoor sensor or the temperature station will correct the interference Windows can reflect the radio signal Metal will absorb the RF radio frequency signal ...

Страница 7: ...related issue Batteries may be overpowered or underpowered Remove batteries from the temperature station Press any button 20 times Leave the temperature station unpowered for 1 2 hours Install fresh Alkaline batteries with correct polarity If the indoor temperature is still shows dashes HH H or LL L the temperature station may need replacement Inaccurate Indoor Temperature Reading Explanation When...

Страница 8: ... date Press the TIME DATE button to confirm and move to 12 24 hour time format 4 12 24 HOUR The time format 12H will flash use the ARROW buttons to choose 12 hour or 24 hour time format and press the TIME DATE button to confirm and move to hour 5 HOUR The Hour will flash use the ARROW buttons to choose the hour and press the TIME DATE button to confirm and move to minutes 6 MINUTES The Minutes wil...

Страница 9: ...powered or underpowered Remove batteries from temperature station Press any button 20 times Leave the batteries out of the display for 2 hours Insert batteries into the temperature station Temperature station drains batteries quickly Test a new set of alkaline batteries Write down the date of installation and the voltage of the batteries When the batteries fail please note the date and voltage aga...

Отзывы: