Consider the signal path from your station to each sensor as a straight line. 

 

Consider the distance the station is from other electronics in the home. 

 

Resistance:  

 

Each obstacle: walls, windows, vegetation, stucco, concrete, and large metal objects will 
reduce the effective signal range by about one-half.  

 

Mounting your sensors on a metal fence can significantly reduce the effective signal range. 

 
Interference:  

 

Consider electronics in the signal path between the sensors and your station.  

 

Simple relocation of the sensors or the station may correct an interference issue. 

 

Windows can reflect the radio signal.  

 

Metal will absorb the RF (radio frequency) signal. 

 

Stucco held to the wall by a metal mesh will cause interference. 

 

Transmitting antennas from: ham radios, emergency dispatch centers, airports, military 
bases, etc. may cause interference. 

 

Electrical wires, utilities, cables, etc. may create interference if too close. 

CAN I CHANGE BATTERIES IN MY SENSORS WITHOUT

 

LOSING DATA? 

S75617: 

We designed this station for convenience, so that a simple change of batteries does not lose 
data or require you to power down your station. 

 

When Battery Indicator shows in the Outdoor Sensor area, replace batteries in your Outdoor 
Sensor.   

 

Then hold the +/OUT button for 3 seconds and your station will search for your sensor. 

 

When changing the batteries in the color station, continue using the power cord.  After 
replacing the batteries, no other action is needed. The batteries in the station only maintain 
time/date in the event of a power outage.  

 

308-147:

 Hold the PLUS button to search for the Outdoor Sensor. 

FACTORY RESET: HOW DO I FACTORY RESET MY STATION? 

 

To factory reset your S75617: 

1.

 

Hold the ALERTS and RAIN buttons together for 5 seconds. 

2.

 

When your station resets it will look for all sensors. Allow at least ten minutes to reacquire 
the sensors. 

 

308-147:

  

1.

 

Remove batteries from the station and sensor for 15 minutes. Press any button 20 times. 

2.

 

Insert fresh alkaline batteries into the sensor and into the station. Allow at least 10 minutes to 
reconnect. 

Содержание S75617

Страница 1: ...stations 3 TIME Does this station have Atomic Time 3 How do I manually set the time 4 How Many Time Zones are available 7 What are the Daylight Saving Time DST Settings 7 WEEKDAY How do I correct the...

Страница 2: ...esh batteries are important for best performance in your sensors and as backup in your clock Batteries with an expiration date of 2028 were manufactured in 2018 We recommend batteries with an expirati...

Страница 3: ...uch as soffit vents and window or door frames For accurate humidity readings avoid placement near vegetation and lakes or other bodies of water when possible Maximum transmission distance from your th...

Страница 4: ...up to 5 nights for the change from Daylight Savings Time to Standard Time and vice versa to occur depending on your location and atmospheric conditions Loss of WWVB signal follow these steps 1 Check f...

Страница 5: ...uage ENGLISH will show Press the OUT or button to change to another language Espa ol or Fran ais or Deutsch Press the SET button to select Beep ON OFF 2 BEEP OFF will show Press the OUT or button to t...

Страница 6: ...ash Press the OUT or button to select HPA 14 Press SET to confirm and move to adjust pressure number PRESSURE will show Pressure number will flash Press the OUT or button to adjust pressure number 15...

Страница 7: ...e in Fall DST Always Off Does not change to DST in the Spring WEEKDAY HOW DO I CORRECT THE DAY OF THE WEEK The day of the week will set when the Year Month and Date are set If your day of the week is...

Страница 8: ...The snow icon appears when the temperature is below 32 F 0 C and the forecast is rainy or stormy Your station calibrates barometric pressure based on its location over time to generate an accurate pe...

Страница 9: ...alling pressure over the past 3 hours WHY DOES THE PRESSURE GRAPH BLINK The bar chart will constantly scroll for visual interest This scroll feature cannot be turned off The bar graph shows the record...

Страница 10: ...ur will flash 4 Press the or buttons to change the hour for the dimmer to be low light level 5 Press the LIGHT button to select start time for dimmer to be on High light level STOP TIME and the hour w...

Страница 11: ...nts e g moister climates If a sensor goes out please wait 2 4 hours for it to reconnect on its own Please be patient these stations can reconnect on after many hours out RF radio frequency communicati...

Страница 12: ...N I CHANGE BATTERIES IN MY SENSORS WITHOUT LOSING DATA S75617 We designed this station for convenience so that a simple change of batteries does not lose data or require you to power down your station...

Страница 13: ...idity with Time Date Indoor LO Humidity with Time Date Outdoor Heat Index Outdoor Dew Point Heat Index Heat Index combines the effects of heat and humidity Heat index will be the same number as the Ou...

Страница 14: ...s in alert range Set Alerts 1 Press and hold the ALERTS button 2s to enter alert set mode 2 Press and release the OUT or button to turn alert ON OFF 3 If alert is ON the alert value is flashing Use th...

Страница 15: ...e Pressure When additional sensors are added press the EXTRA button to cycle through Extra Sensor and Pressure data Add Extra Sensors 1 Install batteries into your extra sensor s Note For Temp Humidit...

Страница 16: ...ith sensor Hold the EXTRA button 2 seconds to search for the sensors in the Extra Sensor Area Icon will flash while searching for sensor Extra sensor area will show dashes during the search When senso...

Отзывы: