53
Table 3. TEST MODE Current
User-selected Charging
current
200 mA
500 mA
700 mA
1000 mA
Thereafter Discharging
current
100 mA
250 mA
350 mA
500 mA
The maximum charging current is 1000 mA and not affected by the number of
rechargeable batteries inserted.
After the test mode is finished, the display will shift between the “Full” sign and the
battery capacity (in mAh or Ah) automatically in 3-second intervals until the rechargeable
batteries are removed. User can switch to other displays by pressing the DISPLAY key.
Battery capacity displayed in
(mAh) as the checking is
finished in Test mode.