background image

 

2. Place the atomic wall clock onto the screw, using the hanging hole on the backside. Gently pull the atomic wall clock 

down to lock the screw into place. 

3. Choose a location 6 feet or more from electronics such as cordless phones, gaming systems, televisions, 

microwaves, routers, etc. 

4. Place within range of the outdoor transmitter.  
5. The maximum transmitting range in open air is 200 feet (96 meters). Obstacles such as walls, windows, 

stucco, concrete, and large metal objects can reduce the range. 

6. For best WWVB reception, orientate the atomic wall clock with the front or the back facing Ft. Collins, 

Colorado and mount on an exterior wall. 
 

Position the Outdoor Transmitter 

 

To achieve a true temperature reading, mount in a shaded location. While the outdoor temperature sensor is weather 
resistant, avoid submersion in water or snow. We recommend that you mount the outdoor temperature sensor on an 
outside North-facing wall.  The transmission range is 200ft(open air). Obstacles such as walls, concrete, and large metal 
objects can reduce the range.  Place both units in desired location, and wait approximately 15 minutes before 
permanently mounting to ensure that there is proper reception.   
 

Wall Mount: 

1. Remove the mounting bracket from the outdoor temperature sensor . 
2. Place the mounting bracket in the desired shaded location (wall or table). 
3. Through the screw holes of the bracket, mark the mounting surface with a pencil. 
4. Screw mounting bracket onto the mounting surface.  Ensure that the screws are flush with the 

bracket. Do not over-tighten. 

5. Insert the outdoor temperature sensor into the bracket. 

 
Note:

 Mounting with adhesive tape is not recommended as a permanent mounting solution.  Only use adhesive tape 

during set-up process. 
 

Care and Maintenance 

 

 

Do Not Mix Old and New Batteries 

 

Do Not Mix Alkaline, Standard, Lithium or Rechargeable Batteries 

 

Do not expose the atomic wall clock to extreme temperatures, vibration or shock.  

 

Keep atomic wall clock dry. 

 

Clean atomic wall clock with a soft damp cloth. Do not use solvents or scouring agents. 

 

The product is not a toy. Keep it out of reach of children. 

 

The product is not to be used for medical purpose or for public information, but is determined for home use only. 

 

The specifications of this product may change without prior notice. 

 

Improper use or unauthorized opening of housing will void the warranty. 

 

If the unit does not work properly, change the batteries. 
 

Specifications 

 

Temperature measuring range 

 

 

Indoor:   

   

 

14.5

°

F to 138

°

F with 0.5

°

F resolution (-9.5

°

C to +59.9

°

C with 0.5

°

C resolution) 

                                                 (“OF” displayed if outside this range) 
 
Outdoor:  

   

 

-39.8

°

F to 139.8

°

F with 0.2

°

F resolution (-39.9

°

C to 59.9

°

C with 0.1

°

C resolution) 

                                    

(“OFL” displayed if outside this range) 

 

Indoor humidity:               

20% to 95% with 1% resolution 

                                        

(“- -“ is displayed if outside the range) 

                                         

(“19%” is displayed below 20%;  "96%“will be displayed above 95%) 

 
Temperature and humidity checking interval: 

Indoor:                            

    Every 8 or 16 seconds 

Outdoor:                         

    Every 4 seconds  

Humidity:                        

    Every 65 seconds 

Содержание KWS-8140-BK

Страница 1: ... Model KWS 8140U IT Instruction Manual The digital atomic wall clock features radio controlled time date alarm indoor temperature and humidity and moon phase Wireless outdoor temperature range open air up to 200 feet 60 96 meters Atomic Wall Clock Outdoor Temperature Transmitter TX40U IT ...

Страница 2: ...place Batteries in the Atomic Wall Clock 7 Position the Atomic Wall Clock 7 Position the Outdoor Transmitter 8 Care and Maintenance 8 Specifications 8 Warranty Information 9 FCC Statement 10 KWS 8140U IT 2 AA Alkaline batteries 9 17 x 1 16 x 8 30 233 x 29 4 x 210 8 mm Features Wireless outdoor temperature F or C Monitors indoor temperature F or C Monitors indoor humidity 12 moon phases Atomic time...

Страница 3: ...hen reset all units see SETUP above otherwise transmission problems may occur The maximum transmission range is 220 feet 60 meters from the outdoor temperature transmitter to the atomic wall clock in open space However this depends on the surrounding environment and interference levels If no reception is possible despite the observation of these factors all system units have to be reset see SETUP ...

Страница 4: ... setting Weekday setting 12 24h time format display ºF ºC temperature setting Time Zone The time zone can be set between the 12 hour range Hold the SET button for 5 seconds 1 The time zone 5 EST will flash Use the button to select the desired time zone Time zone settings 12 11 10 ALA PST MST CST EST ATL EST 4 3 2 1 0 1 2 12 Default EST 2 Press and release the SET button to enter the DST Setting DS...

Страница 5: ...button to select 12 hour or 24 hour time format 3 Press and release the SET button to move to select ºF or ºC Temperature F or C Temperature The temperature setting can be set to either to ºF or ºC Default setting F 1 The characters F or C will flash 2 Use the button to select F for temperature display in degrees Celsius or C for degrees Fahrenheit 3 Press and release the SET button to exit the se...

Страница 6: ...ill be automatically ON when the alarm time is set The alarm icon is visible after the minutes To deactivate the alarm OFF press and release once the ALM button in normal mode display The alarm icon will disappear the alarm is now off Snooze When the alarm sounds press the SNZ button on the back of the clock to activate the snooze feature for 10 minutes Moon Phase The Moon Phase will show accordin...

Страница 7: ... is due to a random security code assigned by the transmitter at start up This code must be received and stored by the atomic wall clock in the first 3 minutes of power being supplied to the transmitter If the atomic wall clock has been operating for more than 5 hours remove batteries from the outdoor transmitter and the atomic wall clock for at least 15 minutes before completing a restart Install...

Страница 8: ...et mark the mounting surface with a pencil 4 Screw mounting bracket onto the mounting surface Ensure that the screws are flush with the bracket Do not over tighten 5 Insert the outdoor temperature sensor into the bracket Note Mounting with adhesive tape is not recommended as a permanent mounting solution Only use adhesive tape during set up process Care and Maintenance Do Not Mix Old and New Batte...

Страница 9: ...ged for the repairs or examination The owner must pay any shipping charges incurred in getting the La Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center La Crosse Technology Ltd will pay ground return shipping charges to the owner of the product to a USA address only The La Crosse Technology Ltd warranty covers all defects in material and workmanship with the fol...

Страница 10: ...protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interferenc...

Отзывы: