background image

7 | 

P a g e

 

 

2.

 

Press SET to confirm and move to the 12/24 hour time format. FORMAT will show and 12Hr will flash. Press the 

+ or - button to select 24 hour time. 

3.

 

Press SET to confirm and move to the hour. The HOUR will flash. Press the + or - button to choose the hour. 

4.

 

Press SET to confirm and move to the minutes. The MINUTES will flash. Press the + or - button to choose the 

minutes. 

5.

 

Press SET to confirm and move to the year. The YEAR will show. 2019 will flash. Press the + or - button to 

change the year. 

6.

 

Press SET to confirm and move to the month. The MONTH will flash. Press the + or - button to change the 

month. 

7.

 

Press SET to confirm and move to the date. DATE will show. Date number will flash. Press the + or - button to 

change the date. 

8.

 

Press SET to confirm and move to the temperature unit. TEMP °F will show. ̊F will flash. Press the + or - button 

if you prefer °C (Celsius). 

9.

 

Press SET to confirm and move to rainfall units.  RAINFALL INCHES will flash. Press the + or – button if you 

prefer RAINFALL MM (millimeters).  

10.

 

Press SET to confirm and move to Rainfall AVERAGE, HIGH, or LOW.  AVERAGE will flash. Press the + or – 

button to select HIGH or LOW if your region of the country receive more or less rain than average.  

11.

 

Press SET to confirm and exit. 

 

FLOWER: WHAT DOES IT MEAN? 

 
Days With Rain and Days Without Rain are represented in numbers and with a Flower graphic. 

This will update at midnight each day and at the start of any Rain Event. 

Example:  If the station is showing 3 Days Without Rain at 2:00PM and a New Rain Event occurs, 

the station should immediately update to 0 Days Without Rain.  At midnight, that reading would 

change to 1 Day With Rain. 

 

If there was Additional Rainfall after midnight, then the following day at midnight, the reading 

would change to 2 Days With Rain. 

 

If there was NO Additional Rainfall after midnight, then the following day at midnight, the 

reading would change to 1 Day Without Rain. 

 

If DAYS WITHOUT RAIN exceed 199, the station will show +199 and remain until rain occurs. 

This is the only time the PLUS (+) sign will show. 

The Flower Graphic will change by rainfall and by AVERAGE, HIGH, LOW selected in the 

program menu. 

Содержание 724-1415BL

Страница 1: ...I place my station 3 What is Distance Resistance Interference 4 READINGS How do I interpret the Rain Readings 4 How do I reset the Rain Readings 5 ALERT 24 Hour Rainfall Alert 6 Alert Sounds Disarm Al...

Страница 2: ...were manufactured in 2018 We recommend batteries with an expiration date at least 6 years in advance of the current year for best performance A minimum voltage of 1 48 volt per battery is required fo...

Страница 3: ...ss transmission range to the rain station is over 330 feet 100 meters in open air not including walls or floors TX141TH Bv2 Mount outdoor temperature sensors vertically and under a bit of an overhang...

Страница 4: ...rrect an interference issue Windows can reflect the radio signal Metal will absorb the RF radio frequency signal Stucco held to the wall by a metal mesh will cause interference Transmitting antennas f...

Страница 5: ...lendar Be sure time is set MONTH Current Month Ex January 1 January 31 At the first month calendar day 0 00 month rain is reset to 0 Accumulated rain from 1st of xx month to current day xx month Curre...

Страница 6: ...lert o Press any button to stop the rain alert sound Disarm alert 1 Hold the HISTORY button for 2 seconds until you see Alert ON 2 Press the or button to turn alert OFF 3 Press HISTORY to exit HOW DO...

Страница 7: ...prefer RAINFALL MM millimeters 10 Press SET to confirm and move to Rainfall AVERAGE HIGH or LOW AVERAGE will flash Press the or button to select HIGH or LOW if your region of the country receive more...

Страница 8: ...fRain 4 days ofRain 0 24 Days WithoutRain 0 6 Days ofRain 0 9 Days WithoutRain 0 3 Days ofRain 0 6 Days WithoutRain 0 3 Days ofRain 25 49 Days WithoutRain 10 14 Days WithoutRain 7 10 Days WithoutRain...

Страница 9: ...CKLIGHT ONLY AVAILABLE WITH POWER CORD USE Press and release the LIGHT button to adjust the backlight 5 levels of intensity Intensity Levels 0FF 1 5 20 50 100 WHAT IS AUTO DIM BACKLIGHT USB Power Cord...

Страница 10: ...the rain station and both sensor at the same time FACTORY RESET HOW DO I FACTORY RESET MY STATION A Factory Restart returns the station to its default settings erases history and to out of the box co...

Страница 11: ...limates If a sensor goes out please wait 2 4 hours for it to reconnect on its own Please be patience these stations can reconnect on after many hours out RF radio frequency communication is not always...

Страница 12: ...peat three times Compare these tests If they still read high then contact support HOW CAN I CLEAN THE RAIN SENSOR 1 Remove rain funnel open locking tabs on both sides and pull off funnel 2 Gently remo...

Страница 13: ...oor temperature The temperatures should be within 4 degrees to be within tolerance If the sensor reads correctly when next to your station then try a different location outside Look for heat sources s...

Страница 14: ...ER MISSING This is generally a power related issue Batteries may be overpowered or underpowered Remove batteries from Rain station Press any button 20 times Leave the Rain station unpowered for 1 2 ho...

Отзывы: