12-Hour time format

 ....................................................................................................10 

Power requirements

 .....................................................................................................10 

Manually set time: Program Menu

 ............................................................................10 

WWVB Atomic time Signal

 ..........................................................................................11 

DST (Daylight Saving Time) Icon

 .............................................................................12 

Backlight

 .........................................................................................................................12 

Forecast Icons inaccurate

 ...........................................................................................12 

Weather station is blank: No letters, numbers or dashed lines

 ........................13 

 

BATTERIES 

 

 

Half of all warranty issues can be resolved with fresh batteries of the appropriate 

voltage.  

 

We suggest name brand alkaline batteries.   

 

Use batteries dated at least six years in advance of the current year. Batteries 

dated earlier than six years from now may still work, but may be unstable in 

performance.   

 

Alkaline batteries manufactured this year will have an expiration date 10 years 

in the future. Battery technology has improved and batteries will maintain 

voltage longer in storage. However, the environment the batteries reside in for 

the 10 years can deplete the power. 

 

Good name brand alkaline batteries make less noise, which reduces the chance 

of RF (radio frequency) interference from the battery compartment. A minimum 

voltage of 1.48V for each battery is necessary for proper performance.  

 

WEATHER STATION FACTORY RESTART 

 

The factory reset will return the wind speed station to its default settings. This will 

clear all previous recorded history, so you may want to write down data before 

taking this step. 

1.

 

Hold down both the LIGHT and ALERTS button together for 5 second. This will 

clear all recorded weather data and reset the station's settings back to default 

2.

 

The weather station will fully populate, clear all records, then return to a normal 

display and search for outdoor sensors. 

3.

 

While searching for the outdoor sensors the Wind Speed, and Outdoor 

4.

 

Temperature/Humidity will show dashes. 

5.

 

Once connected to the outdoor sensors (allow 3 minutes) the Wind Speed, and 

6.

 

Temperature/Humidity will show current readings. 

7.

 

In the absence of wind, this reading will show 0.00. 

 

Dashes = Not connected to sensor 

Zero or current readings = Connected to sensor. 

 

 

 

BATTERY CHANGE 

 

Содержание 327-1417

Страница 1: ...dity 4 Inaccurate outdoor temperature humidity 4 Outdoor Readings are stuck or OFL 4 Intermittent Sensor Readings 4 sensor drains batteries quickly 5 Humidity shows OFL but temperature works 5 Fahrenh...

Страница 2: ...aline batteries make less noise which reduces the chance of RF radio frequency interference from the battery compartment A minimum voltage of 1 48V for each battery is necessary for proper performance...

Страница 3: ...ve 433MHz sensors will read to this wind speed station ADD ON SENSORS You can add up to two TX141TH BCH sensors for extra temp humidity readings on channels 2 or 3 Wind Sensor uses channel 1 1 Remove...

Страница 4: ...high during the day but not at night it is a mounting problem Side by side test Bring the thermo hygro sensor in the house and place it next to the Wind speed station for 2 hours Compare indoor and ou...

Страница 5: ...ning the problem Check the distance and resistance between the sensor and Wind speed station Sensors at the end of the range may work while batteries are fresh but not after they drain a bit Check for...

Страница 6: ...cups 1 Loosen the screw on side of cups 2 Remove cups 3 Install new cups 4 Tighten screw Note The screw in the wind cups will fit on the flat side of the metal stem on the sensor WIND SPEED IS 0 00 C...

Страница 7: ...seconds all readings default back to the 1 hour top wind speed Color Wind Speed Graph The wind speed graph with color sections is based on current wind speed One segment will flash indicating current...

Страница 8: ...RH to 99 RH Outdoor HIGH Humidity ON OFF Outdoor HIGH Humidity Value 10 RH to 99 RH Indoor LOW Temperature ON OFF Indoor LOW Temperature Value 32 F to 99 F 0 C to 37 C Indoor HIGH Temperature ON OFF...

Страница 9: ...ck using a nail or insert one mounting screw through the front Mount the TX141TH BCH sensor on a north facing wall or in any shaded area Under an eave or deck rail is preferred The maximum wireless tr...

Страница 10: ...isture and reduces signal Dirt Receiving a signal through a hill is difficult WEATHER STATION 12 HOUR TIME FORMAT Time display 12 hour or 24 hour format Default is 12 hour time Use the Program Menu to...

Страница 11: ...will flash Press and release the or button to select the correct year Confirm with the SET button and move to the month 9 The month will flash Press and release the or button to select the correct mo...

Страница 12: ...backlight is on continuously when operating the Forecast Station with the 5 volt a c adapter Note When the Adapter is NOT in use the Hi Low Off light feature is not available Try this exercise in a d...

Страница 13: ...ourly and daily then stored in nonvolatile memory IMPORTANT As the Wind speed station builds memory it will compare the current average pressure to the past forty day average pressure for increased ac...

Отзывы: