background image

La Crosse Technology, Ltd. www.lacrossetechnology.com/support 

Page 6 

 

 

Call La Crosse Technology® Store at 608-785-7939 or e-mail from our website if 

you are unsure about the correct item to order. Each item carries the original new 

product warranty and includes access to La Crosse Technology technical support. 

 

Temperature Trend Arrows 

 

Explanation: The indoor and outdoor temperature trend indicators will update every 30 

minutes or less. These trends represent temperature changes over the past three hours. 

 

 

UP ARROW: Temperature rose more than 2°F /1°C in the past three hours 

 

DOWN ARROW: Temperature fell more than 2°F /1°C in the past three hours 

 

HI/LO Temperature readings 

 

Press and release the 

SENSOR

 button to toggle HI/LO temperature readings with time/date 

stamp. 

  Outdoor temperature HI 

  Outdoor temperature LO 

 

  Indoor temperature HI 

  Indoor temperature LO 

  Indoor humidity HI 

  Indoor humidity LO 

 

Mounting/Positioning Outdoor sensor 

 

First: Place the outdoor sensor in the desired shaded location and the temperature station 

in the home. Wait approximately 1 hour before permanently mounting the outdoor sensor 

to ensure that there is proper reception.  

 

POSITION 

 

Mount outdoor temperature outdoor sensors vertically.  

 

Protect the outdoor sensor from standing rain or snow and from the overhead sun, 

which can cause it to read incorrectly.  

 

Mounting under an eave or deck rail works well. 

 

If you choose, you can construct a small roof or box for the outdoor sensor. Be sure a 

box has vents. 

 

Mount the outdoor sensor on the North side where to prevent sun from causing 

incorrect readings.  

 

Mount at least 6 feet in the air for a strong RF (radio frequency) signal. 

 

Outdoor sensors are water resistant, not waterproof.  

 

Avoid more than one wall between the outdoor sensor and the temperature station. 

 

The maximum transmitting range in open air is over 300 feet (91 meters).  

 

Obstacles such as walls, windows, stucco, concrete and large metal objects can 

reduce the range.  

Содержание 308-179ORV2

Страница 1: ...ments 4 Inaccurate Outdoor Temperature Reading 4 Intermittent Outdoor Temperature 4 Outdoor Temperature is stuck or HH H LL L 5 Outdoor sensor drains batteries quickly 5 Outdoor sensor fell The sensor...

Страница 2: ...till work but may be unstable in performance Good name brand batteries make less noise which reduces the chance of RF radio frequency interference from the battery compartment Temperature Station Fact...

Страница 3: ...perature station Factory Restart If the above procedure does not work please try the factory reset Outdoor Temperature Signal Strength If sensor loses connection to the weather station for any reason...

Страница 4: ...tly when next to the temperature station try a different location outside Intermittent Outdoor Temperature Explanation Intermittent problems are the hardest to resolve RF radio frequency communication...

Страница 5: ...rk while batteries are fresh but not after they drain a bit Check for leaking batteries which may damage the outdoor sensor Battery life is over 24 months when using reputable battery brands for both...

Страница 6: ...y HI Indoor humidity LO Mounting Positioning Outdoor sensor First Place the outdoor sensor in the desired shaded location and the temperature station in the home Wait approximately 1 hour before perma...

Страница 7: ...large metal objects can reduce the range Choose a location 6 feet or more from electronics such as cordless phones wireless gaming systems televisions microwaves routers baby monitors etc which can p...

Страница 8: ...Select Temperature Alert Values 1 Hold the ALERTS button 2s to enter alert set mode LO or HI alert icon and ALERT OFF will show for selected area 2 Press and release the or button to turn alert ON 3...

Страница 9: ...the temperature station unpowered for 1 2 hours Install fresh Alkaline batteries with correct polarity If the indoor temperature is still shows dashes HH H or LL L the temperature station may need re...

Страница 10: ...inactive Snooze Alarm When alarm sounds press the ALARM SNOOZE button to silence alarm for 10 minutes The alarm icon will flash SNZ will show and the remaining Snooze Time will count down Press any bu...

Страница 11: ...s 10 Press SET to confirm and exit Temperature station is dim Explanation Most temperature stations have a gray background Place the temperature station at eye level to determine if it is dim Temperat...

Страница 12: ...e down the date of installation and the voltage of the batteries When the batteries fail please note the date and voltage again This is helpful in determining the problem Check for leaking batteries w...

Отзывы: