41
15. Technical data
INSTALLER:
Please leave these instructions with the user.
DATA BADGE LOCATION:
Inside base drawer of cavity.
COUNTRY OF DESTINATION:
USA, Canada.
Connections
Electric
240 V 60 Hz
Gas
½” NPT at rear left-hand side
Maximum total electric load 240 V (including oven
fans, lights, etc.):
Note: The maximum input at any time is
given as the fanned grill, which is all top elements and the fan.
5.17 kW, 21 A
Dimensions
Overall height
minimum 35 15/16” (910 mm)
maximum 36 7/8” (937 mm)
Overall width
43” (1092 mm); see ‘Positioning of Cooker’.
Overall depth
28 5/8” (723 mm)
Minimum space for cooktop
31½” (800 mm)
Weight (unpacked)
385 lbs (175 kg)
Ratings
Oven
Fan element
2.5 kW
Top element
1.2 kW
Browning element
1.15 kW
Bottom element
1.0 kW
Gas Hob
Bypass
Screw*
Natural Gas 4” WC
Propane Gas 10” WC
Input
Orifice
Input
Orifice
Center burners
55
17,000 btu/hr
205
17,000 btu/hr
118
Larger burners
41
12,000 btu/hr
150
12,000 btu/hr
99
Right-hand front burner
33
6,000 btu/hr
112
6,000 btu/hr
68
* The valves in this range are fitted with adjustable bypass screws.The range is supplied with the bypass screws set for Natural gas.For LPG conversion the