COMPONENT MAINTENANCE MANUAL
AVIATION RECORDERS
FA2100CVR
Rev. 15 Page 129
Apr. 14/16
Testing & Fault Isolation
23–70–04
Use or disclosure of information on this sheet is subject
to the restrictions on the cover page of this document.
(l)
Select Store Result =>Output Results. A pop
−
up window will appear dis-
playing the current REFERENCE, and the new VOICE VOLUME and CAM
VOLUME values.
Figure 127. Audio Reference Level Utility, Confirmation
(m) Select Yes to update the Setup reference level file with the values dis-
played, or select No to cancel the update of the Setup reference level file.
(n)
Close the Audio Reference Level menu by selecting the Close button.
NOTE:
The Audio Reference Utility volume value is used to define the VOICE
VOLUME for channels 1,2,3 and the CAM VOLUME for channel 4, for
output to the recorder during CVR tests.
(3)
Part 2 – Sound Card Input Adjustment
(a)
Set the toggle switches on the Loop
−
Back Connector to the following set-
tings: (Switch Settings: Channel 1 and Audio Out).
(b)
Select Utilities => Audio Reference Level Utility to run the Audio Refer-
ence Utility from the CVR Tester menu. At the CVR Tester Pop
−
up menu,
select the OK button
Figure 128. Audio Reference Level Utility, Warning Message
(c)
Select Channel 1 check box ion the Audio Reference Level Menu.
The document reference is online, please check the correspondence between the online documentation and the printed version.