4.6. Calculation of the total load power of L-502 output
circuits
If you intend to use L-502 output circuits to connect any external loads, then the total load
power should not exceed the power specified in the specification (see section
). The
load power should be estimated according to the procedure described below.
The total load power taken from the L-502 power system is:
where
is the total load power taken from digital DO outputs in the "1" state (only for
loads connected to the GND circuit);
— power load removed from the DAC outputs;
— power load, taken from the output of +15 V;
— power load, taken from the output of -15 V;
— power load, taken from the output of +3.3 V;
In turn, the power summands
of the corresponding i-th outputs must be calculated either
through the known load current
by the formula
, or through the known load
resistance
at the i-th output
The power summands
of the corresponding j-th outputs must be calculated either
through the known load current
by the formula
, or through the known load
resistance
at the j-th output
The power
and
should also be calculated either through known load currents
by formulas
,
or through a known load
resistance
, according to
formulas
,
All terms in the power formulas are positive, dimension: power — Watt, current — Ampere,
resistance — Ohm