manualshive.com logo in svg
background image

This Owner's Manual includes all options and accessories

commonly used on this heater.  However, depending on the

configuration purchased, some options and accessories

may not be included.

When calling for technical service assistance, or for other

specific information, always have model number,

configuration number and serial number available.  This

information is contained on the dataplate.  The dataplate is

located on the motor housing of the heater.

This manual will instruct you in the operation and care of

your unit. Have your qualified installer review this manual

with you so that you fully understand the heater and how it 

functions.

The gas supply line installation, installation of the heater,

and repair and servicing of the heater requires continuing

expert training and knowledge of gas heaters and should

not be attempted by anyone who is not so qualified.  See

page 6 for definition of the necessary qualifications.

Contact your local L.B. White distributor or the L.B. White

Co., Inc. for assistance, or if you have any questions about

the use of the equipment or its application.

The L.B. White Co., Inc. has a policy of continuous product

improvement.  It reserves the right to change specifications

and design without notice.

SECTION

PAGE

General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Heater Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Safety Precautions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Installation Instructions

General  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Burner and Gas Control Assembly (Models 324 & 328)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Duct Installation (Models 324 & 326) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Thermostat Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Hose and Regulator Assembly  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Start-Up Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Shut-Down Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Cleaning Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Maintenance Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Service Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Checking Gas Pressure  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

Electrical Connection and Ladder Diagram (Models 326 & 330)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

Troubleshooting Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

Heater Component Function  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Parts Identification

Parts Schematic  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

Parts List  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Warranty Policy  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Replacement Parts and Service  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Table of Contents

General Information

3

Содержание Twin Jet 400

Страница 1: ...e at 1 800 345 7200 Owner s Manual and Instructions Jet 200 and Twin Jet 400 Circulating Construction Heaters ATTENTION ALL USERS This heater has been tested and evaluated by L B White Co Inc as a dir...

Страница 2: ...mage personal injury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this heater can result in Death Serious bodily injury or burns Propert...

Страница 3: ...o qualified See page 6 for definition of the necessary qualifications Contact your local L B White distributor or the L B White Co Inc for assistance or if you have any questions about the use of the...

Страница 4: ...ort Combustion Net Weight lbs Shipping Weight lbs Electrical Supply Volts Hz Phase Amp Draw Dimensions Inches L x W x H Minimum Safe Distances From Nearest Combustible Materials STARTING CONTINUOUS OP...

Страница 5: ...can mask fuel gas odor The o odorant i in p propane LP g gas a and n natural g gas i is colorless a and t the i intensity o of i its o odor c can f fade u under some c circumstances If there is an und...

Страница 6: ...amage 8 The hose assembly shall be visually inspected on a daily basis after heater relocation and when the heater is in use If it is evident there is excessive abrasion or wear or if the hose is cut...

Страница 7: ...ections as necessary to stop the leak After all connections are checked and any leaks are stopped turn on the main burner Stand clear while the main burner ignites to prevent injury caused from hidden...

Страница 8: ...w how to shut off the gas supply to the building and also to the individual heater Contact your fuel gas supplier if you have any questions 14 Any defects found in performing any of the service or mai...

Страница 9: ...er casting See Fig 7 FIG 7 8 Thread the orifice with control assembly into the inlet of the burner casting so that the tip of the burner orifice is flush with the inside of the burner and so the contr...

Страница 10: ...s on the threaded connections 2 Assemble the components together according to the figure This view is to show general assembly of the components only 3 Tighten all connections securely 4 Check a all c...

Страница 11: ...et the thermostat on the control panel to a point above room temperature The main burner will light 1 Close the gas supply valve located on the LP gas supply container 2 Allow the heater to burn off a...

Страница 12: ...e heater a thorough cleaning At this time remove the fan and motor assembly and brush or blow off the fan blade assembly Additionally make sure the burner air inlet venturi ports and the casting are f...

Страница 13: ...then check the following Improper regulator for heater Blockage in gas hose Insufficient size or quantity of LP gas supply containers D COMPLETION 1 Once the proper inlet pressure has been confirmed...

Страница 14: ...NAL WIRES AS SUPPLIED WITH THE HEATER MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 302 F 150 C ELECTRICAL CONNECTION DIAGRAM MOTOR RED GAS CONTROL...

Страница 15: ...lean orifice or screen with compressed plugged air replace pilot orifice or screen if necessary Defective pilot control valve Replace pilot control valve Debris plugging up pilot screen Replace pilot...

Страница 16: ...nameplate on heater for correct gas pressure 8 Gas solenoid valve chatters Defective solenoid in gas valve Replace solenoid valve Models 326 and 330 Gas pressure too high Check dataplate on heater fo...

Страница 17: ...o shut off the flow of gas to the main burner when the pilot flame is extinguished or becomes too small to light the main burner Pilot Tube Formed copper tube used to convey gas from the safety contro...

Страница 18: ...18 1 2 3 4 5 7 6 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 21 23 24 25 26 27 28 29 30 31 32 33 34 35 PARTS IDENTIFICATION PARTS SCHEMATIC...

Страница 19: ...90 N A 120 02990 17 Wheel 130 01099 18 Elbow N A 130 01300 N A 130 01300 19 Nipple N A 130 01142 N A 130 01142 20 Valve 130 20229 21 Connector N A 130 04648 N A 130 04648 22 Tube w Nuts N A 500 20406...

Страница 20: ...of p purchase b by the e end u user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months later than th...

Отзывы: