Shut Down Instructions

If the heater is to be shut down for cleaning, mainte-

nance, or repair, follow steps 1-3. Otherwise, simply 

adjust thermostat to “Off” or “No Heat” or put the HEAT/

VENT switch to the OFF position.

1. Turn thermostat dial to lowest temperature setting.

2.  Allow heater to perform it post purge cool down 

mode.

3. Unplug cord from outlet.

DO NOT DISCONNECT THE ELECTRICAL SUPPLY 

UNTIL THE MAIN FAN MOTOR HAS CYCLED OFF 

FROM COOLING THE HEAT EXCHANGER

Note:

  During normal operation, if either the thermostat 

cycles the heater off or the selector switch is 

put in the OFF position, the main fan motor will 

continue to operate. This is the cool down post 

purge of the heat exchanger. The high limit LED 

will flash during this process. After 3 minutes of 

post purge, the heater will shut-off.

Cleaning Instructions

1. Before cleaning, disconnect electrical supply.

2.  The heater should have dirt or dust removed 

periodically:

a.  Before each use give the heater a general cleaning 

using compressed air or a soft brush or dry rag on 

its case and internal components. At this time, dust 

off the motor case to prevent the motor from over-

heating.

WARNING

Fire, Burn, and Explosion Hazard

■     This heater contains electrical and mechanical 

components in the gas management, and safety 

systems.

■  Such components may become inoperative or 

fail due to dust, dirt, wear and aging.

■  Periodic cleaning and inspection as well as 

proper maintenance are essential to avoid seri-

ous injury or property damage.

b.  At least once a year, give the heater a thorough cleaning. 

At this time, remove the fan wheel assembly and brush or 

blow off and dust that may have accumulated on the fin. 

Additionally, make sure the burner air inlet is free of dust 

accumulation.

Clean all components of the heater with pressurized air, a 

dry brush, or a dry cloth.

Maintenance 

Instructions

BEFORE EACH USE:

■  Check the area surrounding the heater to ensure it is 

clear and free of combustible materials, gasoline, and 

other flammable vapors and liquids.

■  At the installation, ensure the flow of combustion and 

ventilation air is not obstructed.

■  Check all wiring associated terminals and electrical 

components within the heater for corrosion, frayed or cut 

insulation, tight connections, etc. Repair or replace as 

necessary.

■  Review all heater markings (i.e. wiring diagram, 

warnings, 

start-up, shut-down, troubleshooting, etc.) at 

the time of maintenance for legibility. Make sure none are 

cut, torn, or otherwise damaged. Any damaged markings 

must be replaced immediately by contacting the L.B. 

White Co., LLC Data plate, startup and shut-down 

instructions and warnings are available at no cost. A 

nominal charge will be applied for wiring diagrams.

■  Check the main fan drive belt. Make sure the belt is not 

cracked. If so, replace it. Additionally, ensure the belt is 

not slipping, and pulleys are properly aligned and not 

worn.

■  Check air gate adjustment.

■  Inspect all fuel supply lines for cracks, abrasions, or 

ruptures. Replace if needed.

■  Clean and check the igniter and cad cell annually.

WARNING

Fire, Burn, and Explosion Hazard

■     Do not use a pressure washer, water, or liquid 

cleaning solution on any gas controls. Use of a 

pressure washer, water or liquid cleaning solu-

tion on the control board components can cause 

severe personal injury or property damage due 

to water and or liquids.

■  In electrical components and wires causing 

electrical shock or equipment failure.

Содержание Foreman

Страница 1: ...vneR to view maintenance videos for L B White heaters WORLD PROVIDER INNOVATIVE HEATING SOLUTIONS 411 Mason Street Onalaska WI 54650 800 345 7200 608 783 5691 608 783 6115 fax www lbwhite com Foreman Ductable Indirect Fired Oil Heater CI230 230 000 Btuh 67 4 kW 1 2 Fuel Oil Owner s Manual and Instructions View this manual online at www lbwhite com Requires an app like QR Droid for Android or for i...

Страница 2: ... amp CI500 CI750 20 amp 4 Set thermostat to desired room temperature or set thermostat selector switch to the manual position 5 This heater has a rocker style selector switch located on the side of the heater This switch allows for either heat mode or ventilate mode no heat 6 When the switch is set to heat three status lights will be activated in sequence as specific circuits are checked by the he...

Страница 3: ... Out This heater is equipped with the Beckett GeniSys Advanced Burner Control The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor igniter and oil solenoid valve The GeniSys Burner controller has one ignition trial If ignition is not achieved the GeniSys burner control will enter a soft lock out mode Soft lockout the control has shut down for one of the followi...

Страница 4: ...move the fan wheel assembly and brush or blow off and dust that may have accumulated on the fin Additionally make sure the burner air inlet is free of dust accumulation Clean all components of the heater with pressurized air a dry brush or a dry cloth Maintenance Instructions BEFORE EACH USE Check the area surrounding the heater to ensure it is clear and free of combustible materials gasoline and ...

Отзывы: