Connection to LA amplied controllers
Cabling Sokar
Accessory
connector sealing plate (provided)
Screws and fasteners
2 M6×16 screws (mounted on enclosure)
Tools
torque screwdriver
T30 Torx bit
small tool or at screwdriver (3 mm or less)
Min number of operators
1
Assembly
Prerequisite
The cable glands on the connector sealing plate are compatible with cables up to 2 × 2.5 mm² gauge.
Refer to:
•
APPENDIX A: Recommendation for speaker cables
(p.44)
•
(p.33)
About this task
The connector sealing plate has two holes: one for the input cable and one for the cable connecting to the next enclosure
in parallel. By default, the rst hole is tted with a cable gland and the second one with a protective plug. An extra cable
gland is provided with each enclosure.
This procedure describes how to connect the input cable to the enclosure. If the enclosure must be connected in parallel,
replace the protective plug with the extra cable gland and proceed identically for both cables.
Procedure
1.
Remove the two screws from the enclosure.
T30
Sokar owner's manual (EN) version 1.0
35