Corrective maintenance
D/R - HF loudspeaker
Tools
• torque screwdriver
• 4 mm hex bit - spherical head
• 10 mm screwdriver extension
Repair kits
G03315
KR compression driver 1.75'' Syva
×1
×2
G100087
S342
1" HF speaker assembly - 16 ohms
M5×20 hex
Prerequisite
Trapdoor removed.
See
(p.60).
Exploded view
For safety reasons, always use the new screws and spare parts provided in the KR.
If no new screws are available, use blue threadlocker.
Use a spherical head bit to access the screws of the lateral speakers.
If necessary, unplug the cables to remove the speakers. Refer to
Connecting cables to the lter (HF area)
(p.63).
Position the positive (red) connector toward the lter.
x2
3 N.m
4 mm
For each speaker, make sure the driver exit and the waveguide mouth t together.
The speaker plate must be level with the cabinet.
What to do next
(p.40) procedures.
Syva owner's manual (EN) version 1.0
61
Содержание S Series