Inspection and preventive maintenance
Listening test
enclosure
preset
usable bandwidth
Syva
[SYVA]
87 Hz - 20 kHz
Syva Low
[SYVA LOW_100]
from 40 Hz
Syva Sub
[SYVA SUB_100]
from 27 Hz
Procedure
1.
Load the preset on an LA2Xi / LA4X / LA7.16i / LA12X amplied controller.
2.
Connect a sinus generator to the amplied controller.
Risk of hearing damage
Set a low sound level to start and use ear protection to adjust before testing.
3.
Scan the bandwidth focusing on the usable range.
The sound should remain pure and free of unwanted noise.
Troubleshooting for LF/MF speakers
One or more LF/MF speaker produces distorted, buzzing, rubbing, clicking, mufed or weak sound.
Possible causes
• The screws are not tightened with the appropriate torque.
• There is an air leak in the gasket.
• There is dust on the cone.
• The cone is damaged.
• The surround is torn or delaminated.
• The voice coil or the spider is damaged.
Procedure
1.
Perform the speaker disassembly procedure.
2.
Visually inspect the cables and the connectors.
3.
Visually inspect the speaker cone, the voice coil and the spider.
If any damage is visible, replace the speaker.
4.
Carefully clean the speaker with a dry cloth.
5.
Perform the reassembly procedure.
Replace the speaker gasket and the screws.
Apply the recommended torque.
6.
Repeat the listening test.
If the problem persists, replace the speaker.
Troubleshooting for HF drivers
One or more HF driver produces high-frequency harmonic distortions, strange vibrations or weak sound.
Possible causes
• There are foreign particles on the air gap.
• The diaphragm is not centered correctly.
• The screws used for reassembly are too loose.
• The diaphragm is damaged.
Procedure
1.
Perform the diaphragm disassembly procedure.
2.
Visually inspect the diaphragm and the voice coil.
If any damage is visible, replace the diaphragm.
42
Syva owner's manual (EN) version 1.0
Содержание S Series
Страница 1: ...Syva owner s manual EN ...